메뉴 건너뛰기




Volumn 4, Issue 2, 1997, Pages 182-188

Performance limits of PD location based on time-domain reflectometry

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC CABLES; ELECTRIC POWER DISTRIBUTION; ELECTRIC VARIABLES MEASUREMENT; ESTIMATION; MAINTENANCE; NUMERICAL ANALYSIS;

EID: 0031120459     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/94.595245     Document Type: Article
Times cited : (33)

References (15)
  • 1
    • 0025411175 scopus 로고
    • Location and Characterization of Partial Discharge Sites in Shielded Power Cables
    • Apr.
    • M. S. Mashikian, R. Bansal and R. B. Northrop, "Location and Characterization of Partial Discharge Sites in Shielded Power Cables". IEEE Trans. on Power Delivery, Vol. 5, pp. 833-839, Apr. 1990.
    • (1990) IEEE Trans. on Power Delivery , vol.5 , pp. 833-839
    • Mashikian, M.S.1    Bansal, R.2    Northrop, R.B.3
  • 2
    • 0026821837 scopus 로고
    • Cation of Partial Discharge in Shielded Power Cables in Presence of High Noise
    • Feb.
    • M. S. Mashikian, F. Palmieri, R. Bansal and R. B. Northrop, "Cation of Partial Discharge in Shielded Power Cables in Presence of High Noise", IEEE Trans. on Electrical Insulation, Vol. 7, No.1, pp. 37-43, Feb. 1992.
    • (1992) IEEE Trans. on Electrical Insulation , vol.7 , Issue.1 , pp. 37-43
    • Mashikian, M.S.1    Palmieri, F.2    Bansal, R.3    Northrop, R.B.4
  • 3
    • 33747797139 scopus 로고
    • Evaluation of Field Aged Crosslinked Polyethylene Cables by Partial Discharge Location
    • paper No. 93SM 3632 PWRD, Vancouver, Canada, Jul.
    • M. S. Mashikian, et al. "Evaluation of Field Aged Crosslinked Polyethylene Cables by Partial Discharge Location", paper No. 93SM 3632 PWRD, presented at the 1993 IEEE/PES Summer Power Meeting, Vancouver, Canada, Jul. 1993.
    • (1993) 1993 IEEE/PES Summer Power Meeting
    • Mashikian, M.S.1
  • 4
    • 0025748169 scopus 로고
    • Partial Discharge - Part IV: Commercial PD Testing
    • Jan./Feb.
    • J. P. Steiner, "Partial Discharge - Part IV: Commercial PD Testing", IEEE Electrical Insulation Magazine, Vol. 7, No.1, pp. 20-33, Jan./Feb. 1991.
    • (1991) IEEE Electrical Insulation Magazine , vol.7 , Issue.1 , pp. 20-33
    • Steiner, J.P.1
  • 5
    • 0003046951 scopus 로고
    • Partial Discharge - Part VIII: PD testing of Solid Dielectric Cable
    • Sept./Oct.
    • J. C. Chan, P. Duffy, L. J. Hiivala, and J. Wasik, "Partial Discharge - Part VIII: PD testing of Solid Dielectric Cable", IEEE Electrical Insulation Magazine, Vol. 7, No. 5, pp. 9-20, Sept./Oct. 1991.
    • (1991) IEEE Electrical Insulation Magazine , vol.7 , Issue.5 , pp. 9-20
    • Chan, J.C.1    Duffy, P.2    Hiivala, L.J.3    Wasik, J.4
  • 6
    • 0020151110 scopus 로고
    • Instrumentation for the Detection and Location of Incipient Faults on Power Cables
    • Jul.
    • W. L. Weeks, J. P. Steiner, "Instrumentation for the Detection and Location of Incipient Faults on Power Cables", IEEE Trans. on Power Apparatus and Systems, Vol. 101, No. 7, pp. 2328-2336, Jul. 1982.
    • (1982) IEEE Trans. on Power Apparatus and Systems , vol.101 , Issue.7 , pp. 2328-2336
    • Weeks, W.L.1    Steiner, J.P.2
  • 8
    • 0020177886 scopus 로고
    • A New Method for Detection and Location of Distributed Partial Discharge (Cable Fault) in High Voltage Cables under External Interference
    • Sept.
    • M. Beyer, W. Kamm, H. Borsi, and K. Feser, "A New Method for Detection and Location of Distributed Partial Discharge (Cable Fault) in High Voltage Cables Under External Interference", IEEE Trans. on Power Apparatus and Systems, Vol. 101, No. 9, Sept. 1982.
    • (1982) IEEE Trans. on Power Apparatus and Systems , vol.101 , Issue.9
    • Beyer, M.1    Kamm, W.2    Borsi, H.3    Feser, K.4
  • 9
    • 0026818659 scopus 로고
    • Digital Location of Partial Discharge in High Voltage Cables
    • Feb.
    • H. Borsi, "Digital Location of Partial Discharge in High Voltage Cables", IEEE Trans. on Electrical Insulation, Vol. 27, No. 1, Feb. 1992.
    • (1992) IEEE Trans. on Electrical Insulation , vol.27 , Issue.1
    • Borsi, H.1
  • 11
    • 0019551750 scopus 로고
    • Fundamental Limitations in the Measurement of Corona and Partial Discharge
    • April
    • S. A. Boggs, G. C. Stone, "Fundamental Limitations in the Measurement of Corona and Partial Discharge", IEEE Trans. on Electrical Insulation, Vol. 17, No.2, pp. 143-150, April 1982.
    • (1982) IEEE Trans. on Electrical Insulation , vol.17 , Issue.2 , pp. 143-150
    • Boggs, S.A.1    Stone, G.C.2
  • 13
    • 0021512876 scopus 로고
    • Wave Propagation Characteristic in Underground Power Cable
    • Oct.
    • W. L. Weeks, Y. Diao, "Wave Propagation Characteristic in Underground Power Cable", IEEE Trans. on Power Apparatus & Systems, Vol. 103, No. 10, pp. 2816-2826, Oct. 1984.
    • (1984) IEEE Trans. on Power Apparatus & Systems , vol.103 , Issue.10 , pp. 2816-2826
    • Weeks, W.L.1    Diao, Y.2