메뉴 건너뛰기




Volumn 46, Issue 2, 1997, Pages 395-398

Low-voltage standards in the 10 Hz to 1 MHz range

Author keywords

Calibration; Impedance measurement; Micropotentiometer; Thermal converters; Voltage measurement

Indexed keywords

BANDWIDTH; CALIBRATION; ELECTRIC CONVERTERS; ELECTRIC IMPEDANCE MEASUREMENT; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); STANDARDS;

EID: 0031120381     PISSN: 00189456     EISSN: None     Source Type: Journal    
DOI: 10.1109/19.571864     Document Type: Article
Times cited : (15)

References (6)
  • 1
    • 33748019138 scopus 로고
    • Accurate radio-frequency microvoltages
    • May
    • M. C. Selby, "Accurate radio-frequency microvoltages," Trans. AIEE, vol. 72, p. 158, May 1953.
    • (1953) Trans. AIEE , vol.72 , pp. 158
    • Selby, M.C.1
  • 2
    • 0026139257 scopus 로고
    • New low-voltage Standards in the de to 1 MHz frequency range
    • Apr.
    • N. M. Oldham and R. M. Henderson, "New low-voltage Standards in the de to 1 MHz frequency range," IEEE Trans. Instrum. Meas., vol. 40, no. 2, pp. 368-372, Apr. 1991.
    • (1991) IEEE Trans. Instrum. Meas. , vol.40 , Issue.2 , pp. 368-372
    • Oldham, N.M.1    Henderson, R.M.2
  • 3
    • 0028582835 scopus 로고    scopus 로고
    • High accuracy low-voltage ac-dc transfer standards
    • Boulder, CO
    • K.-E. Rydler and P. Simonson, "High accuracy low-voltage ac-dc transfer standards," in Conf. Rec. CPEM'94, Boulder, CO, pp 382-383.
    • Conf. Rec. CPEM'94 , pp. 382-383
    • Rydler, K.-E.1    Simonson, P.2
  • 4
    • 0029745520 scopus 로고    scopus 로고
    • A micropotentiometer-based system for low-voltage calibration of alternating voltage measurement standards
    • Braunschweig, Germany
    • I. Budovsky, "A micropotentiometer-based system for low-voltage calibration of alternating voltage measurement standards," in Conf. Rec. CPEM'96, Braunschweig, Germany, pp 497-498.
    • Conf. Rec. CPEM'96 , pp. 497-498
    • Budovsky, I.1
  • 5
    • 0029765278 scopus 로고    scopus 로고
    • Loading errors in low voltage ac measurements
    • Braunschweig, Germany
    • P. Simonson and K. E. Rydler, "Loading errors in low voltage ac measurements," in Conf. Rec. CPEM'96, Braunschweig, Germany, pp 572-573.
    • Conf. Rec. CPEM'96 , pp. 572-573
    • Simonson, P.1    Rydler, K.E.2
  • 6
    • 0029746372 scopus 로고    scopus 로고
    • Micropotentiometers as ac-dc transfer standards for low-voltage measurements
    • Braunschweig, Germany, June
    • G. Schliestedt, "Micropotentiometers as ac-dc transfer standards for low-voltage measurements," in Conf. Rec. CPEM'96, Braunschweig, Germany, pp 574-575, June 1996.
    • (1996) Conf. Rec. CPEM'96 , pp. 574-575
    • Schliestedt, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.