-
1
-
-
0019159246
-
Justification of the triaxial goniometer in the measurement of joint rotation
-
Chao, E.Y.S., 1980. Justification of the triaxial goniometer in the measurement of joint rotation. Journal of Biomechanics 13, 989-1006.
-
(1980)
Journal of Biomechanics
, vol.13
, pp. 989-1006
-
-
Chao, E.Y.S.1
-
3
-
-
0020759032
-
A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee
-
Grood, E.S. and W.J. Suntay, 1983. A joint coordinate system for the clinical description of three-dimensional motions: Application to the knee. Journal of Biomechanical Engineering 105, 135-144.
-
(1983)
Journal of Biomechanical Engineering
, vol.105
, pp. 135-144
-
-
Grood, E.S.1
Suntay, W.J.2
-
4
-
-
0015255962
-
Measurement of total motion between two body segments, i. Analytical development
-
Kinzel, G.L., A.S. Hall and B.M. Hillberry, 1972. Measurement of total motion between two body segments, i. Analytical development. Journal of Biomechanics 5, 83-105.
-
(1972)
Journal of Biomechanics
, vol.5
, pp. 83-105
-
-
Kinzel, G.L.1
Hall, A.S.2
Hillberry, B.M.3
-
5
-
-
0027901638
-
A kinematic technique for describing wrist joint motion
-
Moore, J.A., C.F. Small, J.T. Bryant, D.R. Pichora, R.E. Ellis and A.M. Hollister, 1993. A kinematic technique for describing wrist joint motion. Proc. Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine 207, 211-218.
-
(1993)
Proc. Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
, vol.207
, pp. 211-218
-
-
Moore, J.A.1
Small, C.F.2
Bryant, J.T.3
Pichora, D.R.4
Ellis, R.E.5
Hollister, A.M.6
-
6
-
-
0025696481
-
An anatomy-based coordinate system for the description of kinematic displacements of the human knee
-
Pennock, G.R. and K.J. Clark, 1990. An anatomy-based coordinate system for the description of kinematic displacements of the human knee. Journal of Biomechanics 23, 1209-1218.
-
(1990)
Journal of Biomechanics
, vol.23
, pp. 1209-1218
-
-
Pennock, G.R.1
Clark, K.J.2
-
7
-
-
0342401037
-
A case-control study of wrist motion in rheumatoid arthritis
-
Stockholm, Sweden
-
Pichora, D.R., C.F. Small, J.T. Bryant, I.L. Dwosh and P.M. Griffiths, 1994. A case-control study of wrist motion in rheumatoid arthritis. 3rd International Symposium on 3D Analysis of Human Movement, Stockholm, Sweden.
-
(1994)
3rd International Symposium on 3D Analysis of Human Movement
-
-
Pichora, D.R.1
Small, C.F.2
Bryant, J.T.3
Dwosh, I.L.4
Griffiths, P.M.5
-
8
-
-
0025741099
-
On the estimation of joint kinematics during gait
-
Ramakrishnan, H.K. and M.P. Kabada, 1991. On the estimation of joint kinematics during gait. Journal of Biomechanics 24, 969-977.
-
(1991)
Journal of Biomechanics
, vol.24
, pp. 969-977
-
-
Ramakrishnan, H.K.1
Kabada, M.P.2
-
10
-
-
0027657059
-
Precision and accuracy of bone landmarks in characterizing hand and wrist position
-
Erratum: Medical Engineering and Physics, 1994, Vol. 16, 176
-
Small, C.F., D.R. Pichora, J.T. Byrant and P.M. Griffiths, 1993. Precision and accuracy of bone landmarks in characterizing hand and wrist position. Journal of Biomedical Engineering 15, 371-378. (Erratum: Medical Engineering and Physics, 1994, Vol. 16, 176.)
-
(1993)
Journal of Biomedical Engineering
, vol.15
, pp. 371-378
-
-
Small, C.F.1
Pichora, D.R.2
Byrant, J.T.3
Griffiths, P.M.4
-
11
-
-
0010926398
-
Validation of a noninvasive optoelectronic measurement system for wrist kinematics
-
Small, C.F., J.T. Bryant, I.L. Dwosh, P.M. Griffiths, D.R. Pichora and B. Zee, in press. Validation of a noninvasive optoelectronic measurement system for wrist kinematics. Clinical Orthopedics.
-
Clinical Orthopedics
-
-
Small, C.F.1
Bryant, J.T.2
Dwosh, I.L.3
Griffiths, P.M.4
Pichora, D.R.5
Zee, B.6
|