Volumn 35, Issue 4, 1997, Pages 277-283
|
Occlusion of an esophagorespiratory fistula with insertion of an esophageal Montgomery and a tracheal Dynamic stent after failure of conventional endoprosthesis;Verschluss einer osophagobronchialen Fistel durch Implantation eines osophagealen Montgomery- und eines trachealen Dynamic-Stents nach Versagen konventioneller Endoprothetik
a a a a a a |
Author keywords
endoprothesis; esophagorespiratory fistula; metal stents
|
Indexed keywords
ADULT;
ARTICLE;
CASE REPORT;
CLINICAL TRIAL;
ENDOPROSTHESIS;
ESOPHAGOBRONCHIAL FISTULA;
FEMALE;
HUMAN;
RADIOGRAPHY;
STENT;
ADENOCARCINOMA;
BRONCHUS FISTULA;
LUNG CARCINOMA;
LUNG TUMOR;
MULTIMODALITY CANCER THERAPY;
PROSTHESIS;
PROSTHESIS FAILURE;
RECURRENT DISEASE;
TRACHEOESOPHAGEAL FISTULA;
ADENOCARCINOMA;
ADULT;
BRONCHIAL FISTULA;
CARCINOMA, BRONCHOGENIC;
COMBINED MODALITY THERAPY;
FEMALE;
HUMANS;
LUNG NEOPLASMS;
PROSTHESIS DESIGN;
PROSTHESIS FAILURE;
RECURRENCE;
STENTS;
TRACHEOESOPHAGEAL FISTULA;
|
EID: 0031111297
PISSN: 00442771
EISSN: None
Source Type: Journal
DOI: None Document Type: Article |
Times cited : (2)
|
References (18)
|