메뉴 건너뛰기




Volumn 23, Issue 4, 1997, Pages 232-235

Analysis of Ni-Ti versus stainless steel instrumentation in resin simulated canals

Author keywords

[No Author keywords available]

Indexed keywords

NICKEL; RESIN; STAINLESS STEEL; TITANIUM; TITANIUM NICKELIDE;

EID: 0031108338     PISSN: 00992399     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0099-2399(97)80053-2     Document Type: Article
Times cited : (35)

References (10)
  • 1
    • 0016545006 scopus 로고
    • The effect of preparation procedures on original canal shape and on apical foramen shape
    • Weine FS, Kelley RF, Lio PJ. The effect of preparation procedures on original canal shape and on apical foramen shape. J Endodon 1975;1:255-62.
    • (1975) J Endodon , vol.1 , pp. 255-262
    • Weine, F.S.1    Kelley, R.F.2    Lio, P.J.3
  • 2
    • 0022141717 scopus 로고
    • The validity of simulated root canals for the investigation of the prepared root canal shape
    • Lim KC, Webber J. The validity of simulated root canals for the investigation of the prepared root canal shape. Int Endod J 1985;18:240-6.
    • (1985) Int Endod J , vol.18 , pp. 240-246
    • Lim, K.C.1    Webber, J.2
  • 3
    • 0025431093 scopus 로고
    • Comparison of mechanical and standard hand instrumentation techniques in curved root canals
    • Campos JM, del Rio C. Comparison of mechanical and standard hand instrumentation techniques in curved root canals. J Endodon 1990;16:230-4.
    • (1990) J Endodon , vol.16 , pp. 230-234
    • Campos, J.M.1    Del Rio, C.2
  • 5
    • 0024033308 scopus 로고
    • The effects of four instrumentation techniques on root canal shape
    • Calhoun G, Montgomery S. The effects of four instrumentation techniques on root canal shape. J Endodon 1988;14:273-7.
    • (1988) J Endodon , vol.14 , pp. 273-277
    • Calhoun, G.1    Montgomery, S.2
  • 6
    • 0026110956 scopus 로고
    • The effects of Canal Master, Flex-R, and K-Flex instrumentation on root canal configuration
    • Leseberg DA, Montgomery S. The effects of Canal Master, Flex-R, and K-Flex instrumentation on root canal configuration. J Endodon 1991;17:59-65.
    • (1991) J Endodon , vol.17 , pp. 59-65
    • Leseberg, D.A.1    Montgomery, S.2
  • 7
    • 0028525857 scopus 로고
    • A comparison of molar root canal preparations using Flexofile, Canal Master U, and Heliapical instruments
    • Roig-Cayon M, Brau-Aguade E, Canalda-Sahli C, Moreno-Aguado V. A comparison of molar root canal preparations using Flexofile, Canal Master U, and Heliapical instruments. J Endodon 1994;20:495-9.
    • (1994) J Endodon , vol.20 , pp. 495-499
    • Roig-Cayon, M.1    Brau-Aguade, E.2    Canalda-Sahli, C.3    Moreno-Aguado, V.4
  • 8
    • 0029264974 scopus 로고
    • A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine driven, and K-flex endodontic instruments
    • Glossen CR, Haller RH, Dove SB, del Rio CE. A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine driven, and K-flex endodontic instruments. J Endodon 1995;21:146-51.
    • (1995) J Endodon , vol.21 , pp. 146-151
    • Glossen, C.R.1    Haller, R.H.2    Dove, S.B.3    Del Rio, C.E.4
  • 9
    • 0021982743 scopus 로고
    • The effect of different files on the preparation shape of severely curved canals
    • EI Deeb ME, Boraas JC. The effect of different files on the preparation shape of severely curved canals. Int Endod J 1985;18:1-7.
    • (1985) Int Endod J , vol.18 , pp. 1-7
    • Ei Deeb, M.E.1    Boraas, J.C.2
  • 10
    • 0025988911 scopus 로고
    • The influence of different root canal instruments on root canal preparation: An in vitro study
    • Briseno BM, Sonnabend E. The influence of different root canal instruments on root canal preparation: an in vitro study. Int Endod J 1991;24:15-23.
    • (1991) Int Endod J , vol.24 , pp. 15-23
    • Briseno, B.M.1    Sonnabend, E.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.