메뉴 건너뛰기




Volumn 25, Issue 2, 1997, Pages 252-260

Gaussian pulse decomposition: An intuitive model of electrocardiogram waveforms

Author keywords

Biomedical signal processing; Chip away decomposition algorithm; Electrocardiogram; Fourier transform; Nonlinear minimization

Indexed keywords

ALGORITHMS; FOURIER TRANSFORMS; FREQUENCY DOMAIN ANALYSIS; ITERATIVE METHODS; PATTERN RECOGNITION; SIGNAL PROCESSING; WAVEFORM ANALYSIS;

EID: 0031105360     PISSN: 00906964     EISSN: None     Source Type: Journal    
DOI: 10.1007/bf02648039     Document Type: Article
Times cited : (32)

References (14)
  • 3
    • 0001150912 scopus 로고
    • Optimization on minicomputers: The Nelder-Mead simplex algorithm
    • edited by A. Woulk. Philadelphia: Society for Industrial and Applied Mathematics
    • Dennis, J. E. Jr., and D. J. Woods. Optimization on minicomputers: the Nelder-Mead simplex algorithm. In: New computing environments: microcomputers in large-scale computing, edited by A. Woulk. Philadelphia: Society for Industrial and Applied Mathematics, 1987, pp. 116-122.
    • (1987) New Computing Environments: Microcomputers in Large-scale Computing , pp. 116-122
    • Dennis Jr., J.E.1    Woods, D.J.2
  • 7
    • 0027159321 scopus 로고
    • ECG data compression by modeling of ECG signals
    • Madhukar, B., and I. S. N. Murthy. ECG data compression by modeling of ECG signals. Comput. Biomed. Res. 26:310-317, 1993.
    • (1993) Comput. Biomed. Res. , vol.26 , pp. 310-317
    • Madhukar, B.1    Murthy, I.S.N.2
  • 11
    • 0026848768 scopus 로고
    • Data compression of ECG's by high-degree polynomial approximation
    • Philips, W., and G. De Jonghe. Data compression of ECG's by high-degree polynomial approximation. IEEE Trans. Biomed. Eng. 39:330-337, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 330-337
    • Philips, W.1    De Jonghe, G.2
  • 12
    • 0019728680 scopus 로고
    • A method for evaluation of QRS shape features using a mathematical model for the ECG
    • Sörnmo, L., P. O. Börjesson, M. Nygårds, and O. Pahlm. A method for evaluation of QRS shape features using a mathematical model for the ECG. IEEE Trans. Biomed. Eng. 28:713-717, 1981.
    • (1981) IEEE Trans. Biomed. Eng. , vol.28 , pp. 713-717
    • Sörnmo, L.1    Börjesson, P.O.2    Nygårds, M.3    Pahlm, O.4
  • 13
    • 0028420006 scopus 로고
    • Nonlinear transforms of ECG signals for digital QRS detection: A quantitative analysis
    • Suppappola, S., and Y. Sun. Nonlinear transforms of ECG signals for digital QRS detection: a quantitative analysis. IEEE Trans. Biomed. Eng. 41:397-400, 1994.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , pp. 397-400
    • Suppappola, S.1    Sun, Y.2
  • 14
    • 0022270421 scopus 로고
    • Removal of baseline wander and power-line interference from the ECG by an efficient FIR filter with a reduced number of taps
    • Van Alsté, J. A., and T. S. Schilder. Removal of baseline wander and power-line interference from the ECG by an efficient FIR filter with a reduced number of taps. IEEE Trans. Biomed. Eng. 32:1052-1060, 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.32 , pp. 1052-1060
    • Van Alsté, J.A.1    Schilder, T.S.2