메뉴 건너뛰기




Volumn 44, Issue 2, 1997, Pages 417-424

Clutter rejection filters in color flow imaging: A theoretical approach

Author keywords

[No Author keywords available]

Indexed keywords

ALGORITHMS; CORRELATION METHODS; CURVE FITTING; FREQUENCY DOMAIN ANALYSIS; FREQUENCY RESPONSE; LEAST SQUARES APPROXIMATIONS; MATHEMATICAL MODELS; MATRIX ALGEBRA; RADAR CLUTTER; RADAR IMAGING; SIGNAL FILTERING AND PREDICTION; TRANSFER FUNCTIONS;

EID: 0031102176     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.585126     Document Type: Article
Times cited : (118)

References (13)
  • 2
    • 0027658707 scopus 로고    scopus 로고
    • Stationary echo cancelling in velocity estimation by time-domain cross-correlation
    • vol. 12, no. , pp. 471-477, 1993
    • J. A. Jensen, "Stationary echo cancelling in velocity estimation by time-domain cross-correlation," IEEE Trans. Med. Imag., vol. 12, no. , pp. 471-477, 1993
    • IEEE Trans. Med. Imag.
    • Jensen, J.A.1
  • 3
    • 0029378406 scopus 로고    scopus 로고
    • On the performance of Regression and step-initialized IIR Clutter filters for color Doppler systems in diagnosing medical ultrasound
    • vol. 42, no. 5, pp. 927-937, 1995
    • A. Kadi and T. Loupas, "On the performance of Regression and step-initialized IIR Clutter filters for color Doppler systems in diagnosing medical ultrasound," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 42, no. 5, pp. 927-937, 1995
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Kadi, A.1    Loupas, T.2
  • 4
    • 0025736942 scopus 로고    scopus 로고
    • An efficient algorithm to remove low frequency Doppler signals in digital Doppler systems
    • vol. 13, no. 2, pp. 135-44, 1991
    • A. P. Hoeks, J. J. van-de-Vorst, A. Dabekaussen, P. J. Brands, and R. S. Reneman, "An efficient algorithm to remove low frequency Doppler signals in digital Doppler systems," Ultrason. Imag., vol. 13, no. 2, pp. 135-44, 1991
    • Ultrason. Imag.
    • Hoeks, A.P.1    Van-de-Vorst, J.J.2    Dabekaussen, A.3    Brands, P.J.4    Reneman, R.S.5
  • 5
    • 0022692830 scopus 로고    scopus 로고
    • Time domain formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross-Correlation
    • vol. 8, pp. 73-85, 1986
    • O. Bonnefous and P. Pesqué, "Time domain formulation of Pulse-Doppler Ultrasound and Blood Velocity Estimation by Cross-Correlation," Ultrason. Imag., vol. 8, pp. 73-85, 1986
    • Ultrason. Imag.
    • Bonnefous, O.1    Pesqué, P.2
  • 6
    • 0026077013 scopus 로고    scopus 로고
    • A new wideband spread target maximum likelihood estimator for blood velocity estimation-Part I: Theory
    • vol. UFFC- 38, no. 1., pp. 1-26, 1991
    • Ferrara and Algazi, "A new wideband spread target maximum likelihood estimator for blood velocity estimation-Part I: Theory," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. UFFC-38, no. 1., pp. 1-26, 1991
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Ferrara1    Algazi2
  • 7
    • 0018910679 scopus 로고    scopus 로고
    • A theoretical study of the scattering of ultrasound from blood
    • vol. BME- 27, no. 2, pp. 61-67, 1980
    • B. A. J. Angelsen, "A theoretical study of the scattering of ultrasound from blood," IEEE Trans. Biomed. Eng., vol. BME- 27, no. 2, pp. 61-67, 1980
    • IEEE Trans. Biomed. Eng.
    • Angelsen, B.A.J.1
  • 8
    • 0026870052 scopus 로고    scopus 로고
    • A unified approach to modeling the backscattered Doppler ultrasound from blood
    • vol. 39, no. 5, pp. 450-61, 1992
    • L. Y. Mo and R. S. Cobbold, "A unified approach to modeling the backscattered Doppler ultrasound from blood," IEEE Trans. Biomed. Eng., vol. 39, no. 5, pp. 450-61, 1992
    • IEEE Trans. Biomed. Eng.
    • Mo, L.Y.1    Cobbold, R.S.2
  • 9
    • 0026315216 scopus 로고    scopus 로고
    • Description of Broadband Pulsed Doppler Ultrasonic Processing using the Two-Dimensional Fourier Transform
    • vol. 13, pp. 301-315, 1991.
    • L. S. Wilson, "Description of Broadband Pulsed Doppler Ultrasonic Processing using the Two-Dimensional Fourier Transform," Ultrason. Imag., vol. 13, pp. 301-315, 1991.
    • Ultrason. Imag.
    • Wilson, L.S.1
  • 10
    • 0028500791 scopus 로고    scopus 로고
    • Autocorrelation Techniques in Color Flow Imaging. Signal model and statistical properties of the Autocorrelation estimates
    • vol. 41, no. 5, pp. 604-612, September 1994
    • H. Torp, K. Kristoffersen, and B. Angelsen, "Autocorrelation Techniques in Color Flow Imaging. Signal model and statistical properties of the Autocorrelation estimates," IEEE Trans. Ultrason., Ferroelect., Freq. Contr., vol. 41, no. 5, pp. 604-612, September 1994
    • IEEE Trans. Ultrason., Ferroelect., Freq. Contr.
    • Torp, H.1    Kristoffersen, K.2    Angelsen, B.3
  • 11
    • 0029162476 scopus 로고    scopus 로고
    • Velocity Matched Spectrum Analysis: A new Method for suppressing Velocity Ambiguity in Doppler Sonogram
    • vol. 21, no. 7, pp. 937-944, 1995
    • H. Torp and K. Kristoffersen, "Velocity Matched Spectrum Analysis: A new Method for suppressing Velocity Ambiguity in Doppler Sonogram," Ultrasound in Medicine and Biology, vol. 21, no. 7, pp. 937-944, 1995
    • Ultrasound in Medicine and Biology
    • Torp, H.1    Kristoffersen, K.2
  • 12
    • 84939739865 scopus 로고    scopus 로고
    • Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique
    • vol. SU- 32, no. 3, pp. 458-464, May 1985
    • C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, "Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique," IEEE Trans. Sonics Ultras., vol. SU-32, no. 3, pp. 458-464, May 1985
    • IEEE Trans. Sonics Ultras.
    • Kasai, C.1    Namekawa, K.2    Koyano, A.3    Omoto, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.