메뉴 건너뛰기




Volumn 39, Issue 1-3, 1997, Pages 291-294

An enzyme-modified chemiluminescence detector for hydrogen peroxide and oxidase substrates

Author keywords

Chemiluminescence; Glucose and lactate detection; Graphite and silica pastes; Hydrogen peroxide; Optrodes

Indexed keywords

CHEMILUMINESCENCE; ENZYMES; ESTERS; HYDROGEN PEROXIDE; SILICA;

EID: 0031084456     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)80221-3     Document Type: Article
Times cited : (33)

References (22)
  • 4
    • 0018005229 scopus 로고
    • Chemiluminescence fiber optic probe for hydrogen peroxide based on the luminol reaction
    • T. Freeman and W. Seitz, Chemiluminescence fiber optic probe for hydrogen peroxide based on the luminol reaction, Anal. Chem., 50 (1978) 1242-1246.
    • (1978) Anal. Chem. , vol.50 , pp. 1242-1246
    • Freeman, T.1    Seitz, W.2
  • 6
    • 0001168843 scopus 로고
    • Luminescence fibre-optic biosensor
    • L. Blum, S. Gauthier and P. Coulet, Luminescence fibre-optic biosensor, Anal. Lett., 21 (1988) 717-726.
    • (1988) Anal. Lett. , vol.21 , pp. 717-726
    • Blum, L.1    Gauthier, S.2    Coulet, P.3
  • 8
    • 33845707936 scopus 로고
    • Photovoltaic determination of hydrogen peroxide with a biophotodiode
    • M. Aizawa, Y. Ikariyama and M. Kuno, Photovoltaic determination of hydrogen peroxide with a biophotodiode. Anal. Lett., B7 (1984) 555-565.
    • (1984) Anal. Lett. , vol.B7 , pp. 555-565
    • Aizawa, M.1    Ikariyama, Y.2    Kuno, M.3
  • 9
    • 0027959857 scopus 로고
    • Photodiode-based chemiluminometric biosensors for hydrogen peroxide and L-lysine
    • F. Preuschoff, U. Spohn, D. Janasek and E. Weber, Photodiode-based chemiluminometric biosensors for hydrogen peroxide and L-lysine, Biosensors Bioelectron., 9 (1994) 543-549.
    • (1994) Biosensors Bioelectron. , vol.9 , pp. 543-549
    • Preuschoff, F.1    Spohn, U.2    Janasek, D.3    Weber, E.4
  • 10
    • 0030039191 scopus 로고    scopus 로고
    • An enzymatic chemiluminescence optrode for choline detection under flow injection conditions
    • H. Lapp, U. Spohn and D. Janasek, An enzymatic chemiluminescence optrode for choline detection under flow injection conditions, Anal. Lett., 29 (1996) 1-17.
    • (1996) Anal. Lett. , vol.29 , pp. 1-17
    • Lapp, H.1    Spohn, U.2    Janasek, D.3
  • 11
    • 4243990095 scopus 로고
    • Electrochemical platinization of reticulated vitreous carbon electrodes to increase biosensor response
    • G. Heider, S. Sasso, K. Huang, A. Yacynych and H. Wieck, Electrochemical platinization of reticulated vitreous carbon electrodes to increase biosensor response, Anal. Chem., 62 (1990) 1106-1111.
    • (1990) Anal. Chem. , vol.62 , pp. 1106-1111
    • Heider, G.1    Sasso, S.2    Huang, K.3    Yacynych, A.4    Wieck, H.5
  • 12
    • 0026562811 scopus 로고
    • Electrocatalysis and flow injection analysis of hydrogen peroxide at a chemically modified electrode
    • Z. Gao, A. Ivaska, P. Li, K. Lui and J. Yang, Electrocatalysis and flow injection analysis of hydrogen peroxide at a chemically modified electrode, Anal. Chim. Acta, 259 (1992) 211-218.
    • (1992) Anal. Chim. Acta , vol.259 , pp. 211-218
    • Gao, Z.1    Ivaska, A.2    Li, P.3    Lui, K.4    Yang, J.5
  • 15
    • 0029084138 scopus 로고
    • Poly(carbamoylsulphonate) hydrogel, a new polymer material for cell entrapment
    • A. Muscat, J. Beyersdorf und K. Vorlop, Poly(carbamoylsulphonate) hydrogel, a new polymer material for cell entrapment, Biosensors Bioelectron., 10 (1995) XI-XIV.
    • (1995) Biosensors Bioelectron. , vol.10
    • Muscat, A.1    Beyersdorf, J.2    Vorlop, K.3
  • 18
    • 0000707017 scopus 로고
    • Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors
    • S. Sasso, R. Pierce, R. Walla and A. Yacynych, Electropolymerized 1,2-diaminobenzene as a means to prevent interferences and fouling and to stabilize immobilized enzyme in electrochemical biosensors, Anal. Chem., 62 (1990) 1111-1117.
    • (1990) Anal. Chem. , vol.62 , pp. 1111-1117
    • Sasso, S.1    Pierce, R.2    Walla, R.3    Yacynych, A.4
  • 19
    • 0029209486 scopus 로고
    • Methylphenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols
    • H. Kotte, B. Gründig, K. Vorlop, B. Strehlitz and U. Stottmeister, Methylphenazonium-modified enzyme sensor based on polymer thick films for subnanomolar detection of phenols, Anal. Chem., 67 (1995) 65-70.
    • (1995) Anal. Chem. , vol.67 , pp. 65-70
    • Kotte, H.1    Gründig, B.2    Vorlop, K.3    Strehlitz, B.4    Stottmeister, U.5
  • 20
    • 0027858998 scopus 로고
    • Fumed-silica containing carbon-paste dehydrogenase biosensors
    • J. Wang and J. Liu, Fumed-silica containing carbon-paste dehydrogenase biosensors, Anal. Chim. Acta, 284 (1993) 385-392.
    • (1993) Anal. Chim. Acta , vol.284 , pp. 385-392
    • Wang, J.1    Liu, J.2
  • 22
    • 84987492148 scopus 로고
    • Carbon paste electrodes modified with enzymes, tissues, and cells
    • L. Gorton, Carbon paste electrodes modified with enzymes, tissues, and cells, Electroanalysis, 7 (1995) 23-45.
    • (1995) Electroanalysis , vol.7 , pp. 23-45
    • Gorton, L.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.