메뉴 건너뛰기




Volumn 39, Issue 1-3, 1997, Pages 277-282

Integrated optical Mach-Zehnder interferometers as simazine immunoprobes

Author keywords

3 3 couplers; Integrated optical immunoprobes; Mach Zehnder interferometers

Indexed keywords

INTEGRATED OPTICS; INTERFEROMETERS; OPTICAL WAVEGUIDES; WAVEGUIDE COUPLERS;

EID: 0031084339     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0925-4005(97)80218-3     Document Type: Article
Times cited : (49)

References (22)
  • 2
    • 0028347313 scopus 로고
    • Real time analysis of competitive binding using grating coupler immunosensor for pesticide detection
    • F.F. Bier and R.D. Schmid, Real time analysis of competitive binding using grating coupler immunosensor for pesticide detection, Biosensors Bioelectron., 9 (1994) 125-130.
    • (1994) Biosensors Bioelectron. , vol.9 , pp. 125-130
    • Bier, F.F.1    Schmid, R.D.2
  • 3
    • 84958310303 scopus 로고
    • Detection of pesticide in drinking water using real-time biospecific interaction analysis (BIA)
    • M. Minnuni and M. Mascini, Detection of pesticide in drinking water using real-time biospecific interaction analysis (BIA), Anal. Lett., 26 (1993) 1441-1460.
    • (1993) Anal. Lett. , vol.26 , pp. 1441-1460
    • Minnuni, M.1    Mascini, M.2
  • 4
    • 0029111431 scopus 로고
    • A direct optical immunosensor for atrazine detection
    • A. Brecht, J. Piehler, G. Lang and G. Gauglitz, A direct optical immunosensor for atrazine detection, Anal. Chim. Acta, 311 (1995) 289-299.
    • (1995) Anal. Chim. Acta , vol.311 , pp. 289-299
    • Brecht, A.1    Piehler, J.2    Lang, G.3    Gauglitz, G.4
  • 5
    • 0029275530 scopus 로고
    • Feasibility of optical waveguide immunosensors for pesticide detection: Physical aspects
    • E.F. Schipper, R.P.H. Kooyman, R.G. Heideman and J. Greve, Feasibility of optical waveguide immunosensors for pesticide detection: physical aspects, Sensors and Actuators B, 24 (1995) 90-93.
    • (1995) Sensors and Actuators B , vol.24 , pp. 90-93
    • Schipper, E.F.1    Kooyman, R.P.H.2    Heideman, R.G.3    Greve, J.4
  • 6
    • 0001085237 scopus 로고
    • Atrazin measurement using surface transverse wave devices
    • M. Tom-Moy, R.L. Baer, D. Spira-Solomon and T.P. Doherty, Atrazin measurement using surface transverse wave devices, Anal. Chem., 67 (1995) 1510-1514.
    • (1995) Anal. Chem. , vol.67 , pp. 1510-1514
    • Tom-Moy, M.1    Baer, R.L.2    Spira-Solomon, D.3    Doherty, T.P.4
  • 8
    • 0020832582 scopus 로고
    • Surface plasmon resonance for gas detection and biosensing
    • B. Liedberg, C. Nylander and I. Lundström, Surface plasmon resonance for gas detection and biosensing, Sensors and Actuators, 4 (1983) 299-304.
    • (1983) Sensors and Actuators , vol.4 , pp. 299-304
    • Liedberg, B.1    Nylander, C.2    Lundström, I.3
  • 9
    • 0025782533 scopus 로고
    • Principles and sensitivities of integrated optical and surface plasmon sensors for direct affinity sensing and immunosensing
    • W. Lukosz, Principles and sensitivities of integrated optical and surface plasmon sensors for direct affinity sensing and immunosensing, Biosensors Bioelectron., 6 (1991) 215-225.
    • (1991) Biosensors Bioelectron. , vol.6 , pp. 215-225
    • Lukosz, W.1
  • 10
    • 0027366806 scopus 로고
    • The resonant mirror: A novel optical biosensor for direct sensing of biomolecular interactions. Part I: principle of operation and associated instrumentation
    • R. Cush, J.M. Cronin, W.J. Stewart, C.H. Maule, J. Molloy and N.J. Goddard, The resonant mirror: a novel optical biosensor for direct sensing of biomolecular interactions. Part I: principle of operation and associated instrumentation, Biosensors Bioelectron., 8 (1993) 347-353.
    • (1993) Biosensors Bioelectron. , vol.8 , pp. 347-353
    • Cush, R.1    Cronin, J.M.2    Stewart, W.J.3    Maule, C.H.4    Molloy, J.5    Goddard, N.J.6
  • 11
    • 0027540637 scopus 로고
    • Performance of a highly sensitive optical waveguide Mach-Zehnder interferometer immunosensor
    • R.G. Heideman, R.P.H. Kooyman and J. Greve, Performance of a highly sensitive optical waveguide Mach-Zehnder interferometer immunosensor, Sensors and Actuators B, 10 (1993) 209-217.
    • (1993) Sensors and Actuators B , vol.10 , pp. 209-217
    • Heideman, R.G.1    Kooyman, R.P.H.2    Greve, J.3
  • 12
    • 0027553258 scopus 로고
    • Integrated optical difference interferometer as refractometer and chemical sensor
    • Ch. Stamm and W. Lukosz, Integrated optical difference interferometer as refractometer and chemical sensor, Sensors and Actuators B, 11 (1993) 177-181.
    • (1993) Sensors and Actuators B , vol.11 , pp. 177-181
    • Stamm, Ch.1    Lukosz, W.2
  • 14
    • 0017858702 scopus 로고
    • Ellipsometry as a tool to study the adsorption behaviour of synthetic and biopolymers at the air-water interface
    • J.A. De Feijter, J. Benjamins and F.A. Veer, Ellipsometry as a tool to study the adsorption behaviour of synthetic and biopolymers at the air-water interface, Biopolymers, 17 (1978) 1759-1772.
    • (1978) Biopolymers , vol.17 , pp. 1759-1772
    • De Feijter, J.A.1    Benjamins, J.2    Veer, F.A.3
  • 15
    • 0031573877 scopus 로고    scopus 로고
    • Studies on the biotin-avidin multilayer adsorption by spectroscopic ellipsometry
    • submitted for publication
    • K. Spaeth, A. Brecht and G. Gauglitz, Studies on the biotin-avidin multilayer adsorption by spectroscopic ellipsometry, J. Colloid Interface Sci., submitted for publication.
    • J. Colloid Interface Sci.
    • Spaeth, K.1    Brecht, A.2    Gauglitz, G.3
  • 18
  • 21
    • 0030371506 scopus 로고    scopus 로고
    • Characterisation and optimisation of an immunoprobe for triazines
    • G. Lang, A. Brecht and G. Gauglitz, Characterisation and optimisation of an immunoprobe for triazines, Fresenius' Z. Anal. Chem., 354 (1996) 857-860.
    • (1996) Fresenius' Z. Anal. Chem. , vol.354 , pp. 857-860
    • Lang, G.1    Brecht, A.2    Gauglitz, G.3
  • 22
    • 0027198367 scopus 로고
    • Antigen-antibody binding and mass transport by convention and diffusion to a surface: A two-dimensional computer model of binding and dissociation kinetics
    • R.W. Glaser, Antigen-antibody binding and mass transport by convention and diffusion to a surface: a two-dimensional computer model of binding and dissociation kinetics, Anal Biochem., 213 (1993) 153-161.
    • (1993) Anal Biochem. , vol.213 , pp. 153-161
    • Glaser, R.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.