Volumn 68, Issue 2, 1997, Pages 1233-1237
|
A fast charge coupled device detector for charge exchange recombination spectroscopy on the DIII-D Tokamak
a a a a a a a |
Author keywords
[No Author keywords available]
|
Indexed keywords
DATABASE SYSTEMS;
ELECTRON SPECTROSCOPY;
IMAGE INTENSIFIERS (ELECTRON TUBE);
PHOTODIODES;
PHOTONS;
RADIATION SHIELDING;
SIGNAL TO NOISE RATIO;
SPECTROMETERS;
TOKAMAK DEVICES;
CHARGE COUPLED DEVICE DETECTOR;
CHARGE EXCHANGE RECOMBINATION SPECTROSCOPY;
MICROCHANNEL PLATES;
NEUTRON SHIELDING;
CHARGE COUPLED DEVICES;
|
EID: 0031075554
PISSN: 00346748
EISSN: None
Source Type: Journal
DOI: 10.1063/1.1147895 Document Type: Article |
Times cited : (13)
|
References (22)
|