메뉴 건너뛰기




Volumn 9, Issue 1, 1997, Pages 15-20

Computer-assisted high-performance liquid chromatographic method, applied to pyrimidine analysis

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER AIDED ANALYSIS; COMPUTER APPLICATIONS; COMPUTER HARDWARE; COMPUTER SYSTEMS; GAS CHROMATOGRAPHY;

EID: 0031074063     PISSN: 08957533     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1098-2728(1997)9:1<15::AID-LRA4>3.0.CO;2-Y     Document Type: Article
Times cited : (1)

References (5)
  • 1
    • 0001964301 scopus 로고
    • Analysis of Purine and Pyrimidines in Blood, Urine, and Other Physiological Fluids
    • F. A. Hommes (ed), Wiley-Liss, Inc., New York
    • H. A. Simmonds, J. A. Duley, and P. M. Davies, "Analysis of Purine and Pyrimidines in Blood, Urine, and Other Physiological Fluids," in F. A. Hommes (ed) Techniques in Diagnostic Human Biochemical Genetics: Laboratory Manual, Wiley-Liss, Inc., New York, pp. 397-424 (1991).
    • (1991) Techniques in Diagnostic Human Biochemical Genetics: Laboratory Manual , pp. 397-424
    • Simmonds, H.A.1    Duley, J.A.2    Davies, P.M.3
  • 2
    • 0018374409 scopus 로고
    • Urinary Excretion of Orotic Acid, and Orotidine and Other Pyrimidines in a Patient with Purine Nucleoside Phosphorylase Deficiency
    • A. H. van Gennip, J. Grift, P. K. de Bree, et al., "Urinary Excretion of Orotic Acid, and Orotidine and Other Pyrimidines in a Patient with Purine Nucleoside Phosphorylase Deficiency," Clinica Chemica Acta 93, 419-428 (1979).
    • (1979) Clinica Chemica Acta , vol.93 , pp. 419-428
    • Van Gennip, A.H.1    Grift, J.2    De Bree, P.K.3
  • 3
    • 0025734534 scopus 로고
    • Automated Determination of Orotic Acid, Uracil and Pseudouridine in Urine by High-Performance Liquid Chromatography with Column Switching
    • S. Ohba, K. Kidouchi, T. Katoh, et al., "Automated Determination of Orotic Acid, Uracil and Pseudouridine in Urine by High-Performance Liquid Chromatography with Column Switching," J. Chromatogr. B 568, 325-332 (1991).
    • (1991) J. Chromatogr. B , vol.568 , pp. 325-332
    • Ohba, S.1    Kidouchi, K.2    Katoh, T.3
  • 4
    • 0029117065 scopus 로고
    • Automated Determination of Hypoxanthine and Xanthine in Urine by High-Performance Liquid Chromatography with Column Switching
    • S. Sumi, K. Kidouchi, S. Ohba, et al., "Automated Determination of Hypoxanthine and Xanthine in Urine by High-Performance Liquid Chromatography with Column Switching," J. Chromatogr. B 670, 376-378 (1995).
    • (1995) J. Chromatogr. B , vol.670 , pp. 376-378
    • Sumi, S.1    Kidouchi, K.2    Ohba, S.3
  • 5
    • 0028828967 scopus 로고
    • Automated Screening System for Purine and Pyrimidine Metabolism Disorders Using High-Performance Liquid Chromatography
    • S. Sumi, K. Kidouchi, S. Ohba, et al., "Automated Screening System for Purine and Pyrimidine Metabolism Disorders Using High-Performance Liquid Chromatography," J. Chromatogr. B, 672, 233-239 (1995).
    • (1995) J. Chromatogr. B , vol.672 , pp. 233-239
    • Sumi, S.1    Kidouchi, K.2    Ohba, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.