메뉴 건너뛰기




Volumn 11, Issue 1, 1997, Pages

Serial peak expiratory flow measurement in the diagnosis of occupational asthma

Author keywords

Diagnosis occupational asthma peak expiratory flow

Indexed keywords

ASTHMA; CIRCADIAN RHYTHM; EPIDEMIOLOGY; HUMAN; INSTRUMENTATION; LUNG FUNCTION TEST; METHODOLOGY; OCCUPATIONAL DISEASE; PEAK EXPIRATORY FLOW; PHYSIOLOGY; REVIEW; SENSITIVITY AND SPECIFICITY; CONFERENCE PAPER; ENVIRONMENTAL EXPOSURE; MEASUREMENT; OCCUPATIONAL ASTHMA; PRIORITY JOURNAL; RESPIRATORY TRACT INFECTION;

EID: 0031063824     PISSN: 09041850     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (36)

References (32)
  • 1
    • 0018758717 scopus 로고
    • Peak flow rate records in the diagnosis of occupational asthma due to colophony
    • Burge PS, O'Brien IM, Harries MG. Peak flow rate records in the diagnosis of occupational asthma due to colophony. Thorax 1979; 34: 308-316.
    • (1979) Thorax , vol.34 , pp. 308-316
    • Burge, P.S.1    O'Brien, I.M.2    Harries, M.G.3
  • 2
    • 0018757078 scopus 로고
    • Peak flow rate records in the diagnosis of occupational asthma due to isocyanates
    • Burge PS, O'Brien IM, Harries MG. Peak flow rate records in the diagnosis of occupational asthma due to isocyanates. Thorax 1979; 34: 317-323.
    • (1979) Thorax , vol.34 , pp. 317-323
    • Burge, P.S.1    O'Brien, I.M.2    Harries, M.G.3
  • 3
    • 0020409123 scopus 로고
    • Single and serial measurement of lung function in the diagnosis of occupational asthma
    • Burge PS. Single and serial measurement of lung function in the diagnosis of occupational asthma. Eur J Respir Dis 1982; 63 (Suppl.): 47-59.
    • (1982) Eur J Respir Dis , vol.63 , Issue.SUPPL. , pp. 47-59
    • Burge, P.S.1
  • 4
    • 2542444741 scopus 로고
    • Bronchial provocation tests in the aetiology, diagnosis and analysis of asthma
    • Pepys J, Hutchcroft BJ. Bronchial provocation tests in the aetiology, diagnosis and analysis of asthma. Am Rev Respir Dis 1979; 119: 505-510.
    • (1979) Am Rev Respir Dis , vol.119 , pp. 505-510
    • Pepys, J.1    Hutchcroft, B.J.2
  • 9
    • 2542465300 scopus 로고
    • Accuracy of measurement of peak flow with different peak flow meters
    • Dickinson SA, Hitchins DJ, Miller MR. Accuracy of measurement of peak flow with different peak flow meters. Thorax 1991; 46: 289P.
    • (1991) Thorax , vol.46
    • Dickinson, S.A.1    Hitchins, D.J.2    Miller, M.R.3
  • 10
    • 0017578306 scopus 로고
    • On observing patterns of airflow obstruction in chronic asthma
    • Turner-Warwick M. On observing patterns of airflow obstruction in chronic asthma. Br J Dis Chest 1977; 71: 73-86.
    • (1977) Br J Dis Chest , vol.71 , pp. 73-86
    • Turner-Warwick, M.1
  • 12
    • 0019142850 scopus 로고
    • Comparison of normal and asthmatic circadian rhythms in peak expiratory flow rate
    • Hetzel MR, Clark TJH. Comparison of normal and asthmatic circadian rhythms in peak expiratory flow rate. Thorax 1980; 35: 732-738.
    • (1980) Thorax , vol.35 , pp. 732-738
    • Hetzel, M.R.1    Clark, T.J.H.2
  • 13
    • 0023558162 scopus 로고
    • Field survey of circadian rhythm in PEF of electronics workers suffering from colophony-induced asthma
    • Randem B, Smolensky MH, Hsi B, Albright D, Burge PS. Field survey of circadian rhythm in PEF of electronics workers suffering from colophony-induced asthma. Chronobiol Int 1987; 4: 263-271.
    • (1987) Chronobiol Int , vol.4 , pp. 263-271
    • Randem, B.1    Smolensky, M.H.2    Hsi, B.3    Albright, D.4    Burge, P.S.5
  • 14
    • 0021207706 scopus 로고
    • Circadian rhythms in peak expiratory flow rate in workers exposed to cotton dust
    • Cinkotai FF, Sharpe TC, Gibbs ACC. Circadian rhythms in peak expiratory flow rate in workers exposed to cotton dust. Thorax 1984; 39: 759-765.
    • (1984) Thorax , vol.39 , pp. 759-765
    • Cinkotai, F.F.1    Sharpe, T.C.2    Gibbs, A.C.C.3
  • 15
    • 0014625715 scopus 로고
    • Circadian acrophase in peak expiratory flow rate and urinary electrolyte excretion of asthmatic children: Phase-shifting of rhythms by prednisolone given in different circadian rhythm phases
    • Reindl R, Falliers C, Chai H, Hillman D, Nelson W. Circadian acrophase in peak expiratory flow rate and urinary electrolyte excretion of asthmatic children: phase-shifting of rhythms by prednisolone given in different circadian rhythm phases. Rass Neurol Vegetat 1970; 23: 5-26.
    • (1970) Rass Neurol Vegetat , vol.23 , pp. 5-26
    • Reindl, R.1    Falliers, C.2    Chai, H.3    Hillman, D.4    Nelson, W.5
  • 17
    • 9444236335 scopus 로고
    • Spectral analysis of peak expiratory flow (PEF) records from workers with suspected occupational asthma
    • Belcher J, Gannon PFG, Pantin CFA, Burge PS. Spectral analysis of peak expiratory flow (PEF) records from workers with suspected occupational asthma. Eur Respir J 1992; 5: Suppl. 15, 403s.
    • (1992) Eur Respir J , vol.5 , Issue.15 SUPPL.
    • Belcher, J.1    Gannon, P.F.G.2    Pantin, C.F.A.3    Burge, P.S.4
  • 18
    • 0023243790 scopus 로고
    • Time series analysis of respiratory responses to indoor and outdoor environmental phenomena
    • Lebowitz MD, Collins L, Holberg CJ. Time series analysis of respiratory responses to indoor and outdoor environmental phenomena. Environ Res 1987; 43: 332-341.
    • (1987) Environ Res , vol.43 , pp. 332-341
    • Lebowitz, M.D.1    Collins, L.2    Holberg, C.J.3
  • 19
    • 1042273557 scopus 로고
    • A study of provocation tests in patients with bronchial asthma
    • Colldahl H. A study of provocation tests in patients with bronchial asthma. Acta Allergol (Kbh) 1952; 5: 133.
    • (1952) Acta Allergol (Kbh) , vol.5 , pp. 133
    • Colldahl, H.1
  • 20
    • 0000780782 scopus 로고
    • The late bronchial reaction in induced asthma
    • Herxheimer H. The late bronchial reaction in induced asthma. Int Arch Allergy 1959; 3: 323-328.
    • (1959) Int Arch Allergy , vol.3 , pp. 323-328
    • Herxheimer, H.1
  • 21
    • 0017694173 scopus 로고
    • Physiological patterns of early morning asthma
    • Hetzel MR, Clark TJH, Houston R. Physiological patterns of early morning asthma. Thorax 1977; 32: 418-423.
    • (1977) Thorax , vol.32 , pp. 418-423
    • Hetzel, M.R.1    Clark, T.J.H.2    Houston, R.3
  • 22
    • 0002342320 scopus 로고
    • A clinical and environmental study of byssinosis in the Lancashire cotton industry
    • Roach SA, Schilling RSF. A clinical and environmental study of byssinosis in the Lancashire cotton industry. Br J Ind Med 1960; 17: 1-9.
    • (1960) Br J Ind Med , vol.17 , pp. 1-9
    • Roach, S.A.1    Schilling, R.S.F.2
  • 23
    • 0021991872 scopus 로고
    • Occupational asthma in a factory with a contaminated humidifier
    • Burge PS, Finnegan M, Horsfield N, et al. Occupational asthma in a factory with a contaminated humidifier. Thorax 1985; 40: 248-254.
    • (1985) Thorax , vol.40 , pp. 248-254
    • Burge, P.S.1    Finnegan, M.2    Horsfield, N.3
  • 24
    • 0023836206 scopus 로고
    • Occupational asthma due to oil mists
    • Robertson AS, Weir DC, Burge PS. Occupational asthma due to oil mists. Thorax 1988; 43: 200-205.
    • (1988) Thorax , vol.43 , pp. 200-205
    • Robertson, A.S.1    Weir, D.C.2    Burge, P.S.3
  • 25
    • 2442538188 scopus 로고
    • Further observations on induced asthma and bronchial hypersensitisation
    • Herxheimer N, Prior FN. Further observations on induced asthma and bronchial hypersensitisation. Int Arch Allergy 1952; 3: 189-207.
    • (1952) Int Arch Allergy , vol.3 , pp. 189-207
    • Herxheimer, N.1    Prior, F.N.2
  • 26
    • 0025193963 scopus 로고
    • Sensitivity and specificity of PO20 and peak expiratory flow rate in cedar asthma
    • Côté J, Kennedy S, Chan-Yeung M. Sensitivity and specificity of PO20 and peak expiratory flow rate in cedar asthma. J Allergy Clin Immunol 1990; 85: 592-598.
    • (1990) J Allergy Clin Immunol , vol.85 , pp. 592-598
    • Côté, J.1    Kennedy, S.2    Chan-Yeung, M.3
  • 27
    • 0021211377 scopus 로고
    • Peak flow rate records in surveys: Reproducibility of observers reports
    • Venables RM, Burge PS, Davidson AG, Newman Taylor AJ. Peak flow rate records in surveys: reproducibility of observers reports. Thorax 1984; 39: 828-832.
    • (1984) Thorax , vol.39 , pp. 828-832
    • Venables, R.M.1    Burge, P.S.2    Davidson, A.G.3    Newman Taylor, A.J.4
  • 28
    • 0026601719 scopus 로고
    • Occupational asthma: Validity of monitoring peak expiratory flow rates and non-allergic bronchial responsiveness as compared to specific inhalational challenge
    • Perrin B, Lagier F, L'Archeveque J, Cartier A, Boulet LP, Côté J, Malo J-L. Occupational asthma: validity of monitoring peak expiratory flow rates and non-allergic bronchial responsiveness as compared to specific inhalational challenge. Eur Respir J 1992; 5: 40-48.
    • (1992) Eur Respir J , vol.5 , pp. 40-48
    • Perrin, B.1    Lagier, F.2    L'Archeveque, J.3    Cartier, A.4    Boulet, L.P.5    Côté, J.6    Malo, J.-L.7
  • 29
    • 85045803535 scopus 로고
    • Objective versus qualitative analysis of PEF in the diagnosis of occupational asthma
    • Côté J, Kennedy SM, Chan-Yeung M. Objective versus qualitative analysis of PEF in the diagnosis of occupational asthma (abstract). Am Rev Respir Dis 1990; 141: A82.
    • (1990) Am Rev Respir Dis , vol.141
    • Côté, J.1    Kennedy, S.M.2    Chan-Yeung, M.3
  • 31
    • 0023090532 scopus 로고
    • Problems in the diagnosis of occupational asthma
    • Burge PS. Problems in the diagnosis of occupational asthma. Br J Dis Chest 1987; 81: 105-115.
    • (1987) Br J Dis Chest , vol.81 , pp. 105-115
    • Burge, P.S.1
  • 32
    • 0025794154 scopus 로고
    • Comparison of peak expiratory flow rate and FEV1 in assessing bronchomotor tone after challenges to occupational sensitisers
    • Berube D, Cartier A, L'Archeveque RT, Ghezzo H, Malo JL. Comparison of peak expiratory flow rate and FEV1 in assessing bronchomotor tone after challenges to occupational sensitisers. Chest 1991; 99: 831-836.
    • (1991) Chest , vol.99 , pp. 831-836
    • Berube, D.1    Cartier, A.2    L'Archeveque, R.T.3    Ghezzo, H.4    Malo, J.L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.