메뉴 건너뛰기




Volumn 90, Issue 1, 1997, Pages 41-50

Accuracy of the main Doppler methods for the evaluation of the carotid degree of stenosis. CW, PW and color Doppler;Etude comparative des methodes doppler pour l'evaluation du degre des stenoses carotidiennes. Doppler continu, pulse, couleur

Author keywords

[No Author keywords available]

Indexed keywords

ANGIOGRAPHY; ARTICLE; CAROTID ARTERY OBSTRUCTION; DOPPLER ECHOGRAPHY; HUMAN; MAJOR CLINICAL STUDY; STENOSIS; BLOOD FLOW VELOCITY; BRAIN ANGIOGRAPHY; CLASSIFICATION; COLOR ULTRASOUND FLOWMETRY; COMPARATIVE STUDY; DOPPLER FLOWMETRY; ECHOGRAPHY; HEMODYNAMICS; INSTRUMENTATION; INTERNAL CAROTID ARTERY; METHODOLOGY; PATHOLOGY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY;

EID: 0031053686     PISSN: 00039683     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (6)

References (17)
  • 1
    • 0028945018 scopus 로고
    • Quantification and assessment of the carotid lesions : Stenosis degree and plaque volume
    • Arbeille P, Desombre C, Aesch B. Quantification and assessment of the carotid lesions : stenosis degree and plaque volume. J Clin Ultrasound 1995 ; 23 : 113-24.
    • (1995) J Clin Ultrasound , vol.23 , pp. 113-124
    • Arbeille, P.1    Desombre, C.2    Aesch, B.3
  • 2
    • 0021845714 scopus 로고
    • Die Dopplersonographie der extrakraniellen Arteria carotis mit und ohne Doppier-Frequenz-Spektrum-Analyse
    • Fisher M, Alexander K. Die Dopplersonographie der extrakraniellen Arteria carotis mit und ohne Doppier-Frequenz-Spektrum-Analyse. Akt Neurol 1985 ; 12 : 90-3.
    • (1985) Akt Neurol , vol.12 , pp. 90-93
    • Fisher, M.1    Alexander, K.2
  • 3
    • 0019844491 scopus 로고
    • Incidence of symptomatic extracranial arterial disease
    • Hennerki M, Aulich A, Sandmann W, Freund HJ. Incidence of symptomatic extracranial arterial disease. Stroke 1981 ; 12 : 750-8.
    • (1981) Stroke , vol.12 , pp. 750-758
    • Hennerki, M.1    Aulich, A.2    Sandmann, W.3    Freund, H.J.4
  • 4
    • 84879282836 scopus 로고
    • Accuracy of carotid doppier peak frequency analysis : Results determined by receiver operating characteristics curves and likelihood ratios
    • Johnston KW, Haynes RB, Douville Y, Lally ME, Brown PM, Cobbold RSC. Accuracy of carotid doppier peak frequency analysis : results determined by receiver operating characteristics curves and likelihood ratios. J Vase Sura 1985 ; 2 : 515-23.
    • (1985) J Vase Sura , vol.2 , pp. 515-523
    • Johnston, K.W.1    Haynes, R.B.2    Douville, Y.3    Lally, M.E.4    Brown, P.M.5    Cobbold, R.S.C.6
  • 5
    • 0025858388 scopus 로고
    • Does color-flow imaging improve the accuracy of duplex carotid evaluation
    • Londrey G, Spadone D, Hodgson K. Does color-flow imaging improve the accuracy of duplex carotid evaluation. J Vase Surg 1991 ; 13 : 659-8.
    • (1991) J Vase Surg , vol.13 , pp. 659-668
    • Londrey, G.1    Spadone, D.2    Hodgson, K.3
  • 6
    • 0344450102 scopus 로고
    • Technic of Doppler examination
    • Spencer M, Reid J, eds. The Hague : Martinus Nijhoff-Publisher
    • Spencer MP. Technic of Doppler examination. In : Spencer M, Reid J, eds. Cerebrovascular evaluation with Doppler ultrasound. The Hague : Martinus Nijhoff-Publisher 1981 : 73-80.
    • (1981) Cerebrovascular Evaluation with Doppler Ultrasound , pp. 73-80
    • Spencer, M.P.1
  • 8
    • 0021143199 scopus 로고
    • Evaluation du degré des sténoses carotidiennes par l'analyse spectrale du signal doppler. Confrontation des résultats de l'angiographie et de l'anatomopathologie
    • Arbeille P, Lapierre F, Benhamou AC. Evaluation du degré des sténoses carotidiennes par l'analyse spectrale du signal doppler. Confrontation des résultats de l'angiographie et de l'anatomopathologie. Arch Mal Cœur 1984 ; 10 : 1097-107.
    • (1984) Arch Mal Cœur , vol.10 , pp. 1097-1107
    • Arbeille, P.1    Lapierre, F.2    Benhamou, A.C.3
  • 9
    • 0005503560 scopus 로고
    • Quantification of carotid stenosis using a CW doppler and spectral analysis
    • Spencer M (ed). Martinus Nijhoff Publisher
    • Arbeille P, Lapierre F, Patat F. Quantification of carotid stenosis using a CW doppler and spectral analysis. In : Spencer M (ed). Ultrasonic diagnosis of cerebral disease. Martinus Nijhoff Publisher 1987 : 178-82.
    • (1987) Ultrasonic Diagnosis of Cerebral Disease , pp. 178-182
    • Arbeille, P.1    Lapierre, F.2    Patat, F.3
  • 10
    • 0344018839 scopus 로고
    • Real-time doppler spectrum analysis : Predictive value of defining operable carotid artery disease
    • Barnes RW, Rittgers SE, Putney WW. Real-time doppler spectrum analysis : predictive value of defining operable carotid artery disease. Arch Surg 1981 ; 57 : 172-7.
    • (1981) Arch Surg , vol.57 , pp. 172-177
    • Barnes, R.W.1    Rittgers, S.E.2    Putney, W.W.3
  • 11
    • 0022998615 scopus 로고
    • Quantitative analysis of continuous-wave doppler spectral broadening for the diagnosis of carotid disease : Results of a multicenter study
    • Johnston KW, Baker WH, Burnham SJ, Hayes AC, Kupper CA, Pool MA. Quantitative analysis of continuous-wave doppler spectral broadening for the diagnosis of carotid disease : results of a multicenter study. J Vase Sura 1986 ; 4 : 493-504.
    • (1986) J Vase Sura , vol.4 , pp. 493-504
    • Johnston, K.W.1    Baker, W.H.2    Burnham, S.J.3    Hayes, A.C.4    Kupper, C.A.5    Pool, M.A.6
  • 12
    • 0024306287 scopus 로고
    • Internal carotid artery stenosis : Accuracy and reproducibility of color-Doppler assisted duplex imaging
    • Polak JF, Dobkin GR, O'Leary DH. Internal carotid artery stenosis : accuracy and reproducibility of color-Doppler assisted duplex imaging. Radiology 1989 ; 173 : 793-800.
    • (1989) Radiology , vol.173 , pp. 793-800
    • Polak, J.F.1    Dobkin, G.R.2    O'Leary, D.H.3
  • 14
    • 0027410697 scopus 로고
    • Correlation of North America symptomatic carotid endarterectomy trial (NASCET) angiographic definition of 70 to 99% internal carotid artery stenosis with duplex scanning
    • Moneta GL, Edwards JM, Chitwood RW et al. Correlation of North America symptomatic carotid endarterectomy trial (NASCET) angiographic definition of 70 to 99% internal carotid artery stenosis with duplex scanning. J Vase Surg 1993 ; 17 : 152-9.
    • (1993) J Vase Surg , vol.17 , pp. 152-159
    • Moneta, G.L.1    Edwards, J.M.2    Chitwood, R.W.3
  • 16
    • 0024338142 scopus 로고
    • Stenosis of the internal carotid artery : Assessment using color Doppler imaging compared with angiography
    • Erickson SJ, Mewissen MW, Foley WD. Stenosis of the internal carotid artery : assessment using color Doppler imaging compared with angiography. AJR 1988 ; 152 : 1299-305
    • (1988) AJR , vol.152 , pp. 1299-1305
    • Erickson, S.J.1    Mewissen, M.W.2    Foley, W.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.