Volumn 35, Issue 1, 1997, Pages 2-8

Experimental correlation-based identification of X-ray CT point spread function. Part 1: Method and experimental results

Author keywords

CT scanner; Cupping; Identification; Noise; Non parametric; Point spread function; Pseudo randomly located holes; Wiener Hopf

Indexed keywords

COMPUTERIZED TOMOGRAPHY; CORRELATION METHODS; IMAGING SYSTEMS; MEDICAL IMAGING; NUCLEAR MEDICINE; SPURIOUS SIGNAL NOISE;

EID: 0031053604     PISSN: 01400118     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02510384     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 0017365965 scopus 로고
    • Modulation transfer function of the EMI CT head scanner
    • BISCHOF, C. J., and EHRHARDT, J. C. (1977): 'Modulation transfer function of the EMI CT head scanner,' Med. Phys., 4, pp. 163-167
    • (1977) Med. Phys. , vol.4 , pp. 163-167
    • Bischof, C.J.1    Ehrhardt, J.C.2
  • 4
    • 0023577511 scopus 로고
    • A method for modulation transfer function determination from edge profiles with correction for finite element differentiation
    • CUNNINGHAM, I. A., and FENSTER, A. (1987): 'A method for modulation transfer function determination from edge profiles with correction for finite element differentiation,' Med. Phys., 14, pp. 533-537
    • (1987) Med. Phys. , vol.14 , pp. 533-537
    • Cunningham, I.A.1    Fenster, A.2
  • 6
    • 0031046360 scopus 로고
    • Experimental correlation-based identification of X-ray CT point spread function. Part 2 simulation and design of input signal
    • DORÉ, S., KEARNEY, R. E., and DE GUISE, J. A. (1977): 'Experimental correlation-based identification of X-ray CT point spread function. Part 2 simulation and design of input signal,' Med. Biol. Eng Comput., 35, (1), pp. 9-16
    • (1977) Med. Biol. Eng Comput. , vol.35 , Issue.1 , pp. 9-16
    • Doré, S.1    Kearney, R.E.2    De Guise, J.A.3
  • 7
    • 0019913387 scopus 로고
    • A practical method to measure the MTF of CT scanners
    • DROEGE, R. T., and MORIN, R. L. (1982): 'A practical method to measure the MTF of CT scanners,' Med. Phys., 9, pp. 758-760
    • (1982) Med. Phys. , vol.9 , pp. 758-760
    • Droege, R.T.1    Morin, R.L.2
  • 8
    • 0022337957 scopus 로고
    • An MTF method immune to aliasing
    • DROEGE, R. T., and RZESZOTARSKI, M. S. (1985): 'An MTF method immune to aliasing,' ibid., 12, pp. 721-725
    • (1985) Med. Phys. , vol.12 , pp. 721-725
    • Droege, R.T.1    Rzeszotarski, M.S.2
  • 9
    • 0027590730 scopus 로고
    • Non-parametric 2-D point spread function estimation for biomedical imaging
    • DOUKOGLOU, T. D. HUNTER, I. W., and KEARNEY, R. E. (1993): 'Non-parametric 2-D point spread function estimation for biomedical imaging,' Med. Biol. Eng. Compt., 31, pp. 277-283
    • (1993) Med. Biol. Eng. Compt. , vol.31 , pp. 277-283
    • Doukoglou, T.D.1    Hunter, I.W.2    Kearney, R.E.3
  • 10
    • 0023025865 scopus 로고
    • Reduction of aliasing in modulation transfer function measurements
    • EHRHARDT, J. C. (1986): 'Reduction of aliasing in modulation transfer function measurements,' Med. Phys., 13, pp. 658-662
    • (1986) Med. Phys. , vol.13 , pp. 658-662
    • Ehrhardt, J.C.1
  • 11
    • 84964144866 scopus 로고
    • The theory of the correlation method of dynamic analysis and its application to industrial processes and nuclear power plant
    • GODFREY, K. R. (1969): 'The theory of the correlation method of dynamic analysis and its application to industrial processes and nuclear power plant,' Meas. Control, 2, pp. T65-T72
    • (1969) Meas. Control , vol.2
    • Godfrey, K.R.1
  • 12
    • 0019460905 scopus 로고
    • The exponential edge- Gradient effect in X-ray computed tomography
    • JOSEPH, P. M. and SPITAL, R. D. (1981): 'The exponential edge- gradient effect in X-ray computed tomography,' Phys. Med. Biol., 26, pp. 473-487
    • (1981) Phys. Med. Biol. , vol.26 , pp. 473-487
    • Joseph, P.M.1    Spital, R.D.2
  • 13
    • 0017066097 scopus 로고
    • The line spread function and modulation transfer function of a computed tomography scanner
    • JUDY, P. F. (1976): 'The line spread function and modulation transfer function of a computed tomography scanner,' Med. Phys., 3, pp. 233-236
    • (1976) Med. Phys. , vol.3 , pp. 233-236
    • Judy, P.F.1
  • 14
    • 0020644666 scopus 로고
    • Gamma camera MTFs from edge response function measurements
    • LOGAN, K. W. and HICKEY, K. A. (1983): 'Gamma camera MTFs from edge response function measurements,' ibid, 10, pp. 361-364
    • (1983) Med. Phys. , vol.10 , pp. 361-364
    • Logan, K.W.1    Hickey, K.A.2
  • 15
    • 0017118152 scopus 로고
    • Comparative modulation transfer functions of the EMI and Delta scanners
    • MCINTYRE, W. J., ALFIDI, R. J., HAAGA, J., CHERNAK, E., and MEANY, T. F. (1976): 'Comparative modulation transfer functions of the EMI and Delta scanners,' Radial., 120, pp. 189-191
    • (1976) Radial. , vol.120 , pp. 189-191
    • Mcintyre, W.J.1    Alfidi, R.J.2    Haaga, J.3    Chernak, E.4    Meany, T.F.5
  • 16
    • 0021858245 scopus 로고
    • Simplified approach for modulation transfer function determination in computed tomography
    • NICKOLOFF, E. L., and RILEY, R. (1985): 'Simplified approach for modulation transfer function determination in computed tomography,' Med. Phys., 12, pp. 437-442
    • (1985) Med. Phys. , vol.12 , pp. 437-442
    • Nickoloff, E.L.1    Riley, R.2
  • 17
    • 0023870198 scopus 로고
    • Measurement of the PSF for a CT scanner: Appropriate wire diameter and pixel size
    • NICKOLOFF, E. L. (1988): 'Measurement of the PSF for a CT scanner: appropriate wire diameter and pixel size,' Phys. Med. Biol., 33, pp. 149-155
    • (1988) Phys. Med. Biol. , vol.33 , pp. 149-155
    • Nickoloff, E.L.1
  • 18
    • 0017879337 scopus 로고
    • Single-step calculation of the MTF from the ERFJ
    • SCHNEIDERS, N. J. and BUSHONG, S. C. (1978): 'Single-step calculation of the MTF from the ERFJ,' Med. Phys., 5, pp. 31-33
    • (1978) Med. Phys. , vol.5 , pp. 31-33
    • Schneiders, N.J.1    Bushong, S.C.2
  • 19
    • 0018360872 scopus 로고
    • Blurring in tomograms made with X-ray beams of finite width
    • VERLY, J. G. and BRACEWELL, R. N. (1979): 'Blurring in tomograms made with X-ray beams of finite width,' J. Comput. Ass. Tomography, 3, pp. 662-678
    • (1979) J. Comput. Ass. Tomography , vol.3 , pp. 662-678
    • Verly, J.G.1    Bracewell, R.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.