Volumn 38, Issue 2, 1997, Pages 334-340

Weighted summation of oxygen-15-water PET data to increase signal-to- noise ratio for activation studies

Author keywords

activation study; PET; signal to noise ratio

Indexed keywords

OXYGEN 15;

EID: 0031053258     PISSN: 01615505     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (13)

References (31)
  • 1
    • 0021240859 scopus 로고
    • Stimulus rate dependence of regional cerebral blood flow in human striate cortex demonstrated by positron emission tomography
    • Fox PT, Raichle ME. Stimulus rate dependence of regional cerebral blood flow in human striate cortex demonstrated by positron emission tomography. J Neurophysiol 1984;51:1109-1121.
    • (1984) J Neurophysiol , vol.51 , pp. 1109-1121
    • Fox, P.T.1    Raichle, M.E.2
  • 2
    • 0026271774 scopus 로고
    • The neurotransmitter basis of cognition: Psychopharmacological activation studies using positron emission tomography
    • Chadwick D, Whelan J, eds. West Sussex: John Wiley and Sons
    • Friston KJ, Grasby PM, Frith CD, et al. The neurotransmitter basis of cognition: psychopharmacological activation studies using positron emission tomography. In: Chadwick D, Whelan J, eds. Ciba foundation symposium 163: exploring brain functional anatomy with positron tomography. West Sussex: John Wiley and Sons; 1991:76-87.
    • (1991) Ciba Foundation Symposium 163: Exploring Brain Functional Anatomy with Positron Tomography , pp. 76-87
    • Friston, K.J.1    Grasby, P.M.2    Frith, C.D.3
  • 7
    • 0343065380 scopus 로고
    • Length of PET data acquisition inversly affects ability to detect focal areas of brain activation
    • Mintun MA, Raichle ME, Quarles RP. Length of PET data acquisition inversly affects ability to detect focal areas of brain activation. J Cereb Blood Flow Metab 1989; 9(suppl 1):349.
    • (1989) J Cereb Blood Flow Metab , vol.9 , Issue.1 SUPPL. , pp. 349
    • Mintun, M.A.1    Raichle, M.E.2    Quarles, R.P.3
  • 9
    • 0026098691 scopus 로고
    • Sensitivity of measurements of regional brain activation with oxygen-15-water and PET to time of stimulation and period of image reconstruction
    • Volkow ND, Mullani NA, Gould LK, Adler SS, Galley SJ. Sensitivity of measurements of regional brain activation with oxygen-15-water and PET to time of stimulation and period of image reconstruction. J Nucl Med 1991;32:58-61.
    • (1991) J Nucl Med , vol.32 , pp. 58-61
    • Volkow, N.D.1    Mullani, N.A.2    Gould, L.K.3    Adler, S.S.4    Galley, S.J.5
  • 11
    • 0029012866 scopus 로고
    • Brain stem activation in spontaneous human migraine attacks
    • Weiller C, May A, Limmroth V, et al. Brain stem activation in spontaneous human migraine attacks. Nature Medicine 1995;1:658-660.
    • (1995) Nature Medicine , vol.1 , pp. 658-660
    • Weiller, C.1    May, A.2    Limmroth, V.3
  • 12
    • 0026776405 scopus 로고
    • Rapid automated algorithm for aligning and reslicing PET images
    • Woods RP, Cherry SR, Mazziotta JC. Rapid automated algorithm for aligning and reslicing PET images. J Comput Assist Tomogr 1992;16:620-633.
    • (1992) J Comput Assist Tomogr , vol.16 , pp. 620-633
    • Woods, R.P.1    Cherry, S.R.2    Mazziotta, J.C.3
  • 13
    • 0028938469 scopus 로고
    • A rapid and accurate method to realign PET scans utilizing image edge information
    • Andersson JLR. A rapid and accurate method to realign PET scans utilizing image edge information. J Nucl Med 1995;36:657-669.
    • (1995) J Nucl Med , vol.36 , pp. 657-669
    • Andersson, J.L.R.1
  • 14
    • 0002948822 scopus 로고
    • Statistical parametric mapping
    • Thatcher RW, Hallet M, Zeffiro T, John ER, Huerta M, eds. San Diego: Academic Press
    • Friston KJ. Statistical parametric mapping. In: Thatcher RW, Hallet M, Zeffiro T, John ER, Huerta M, eds. Functional neuroimaging: technical foundations. San Diego: Academic Press; 1994:79-93.
    • (1994) Functional Neuroimaging: Technical Foundations , pp. 79-93
    • Friston, K.J.1
  • 15
    • 0026781154 scopus 로고
    • A three-dimensional statistical analysis for CBF activation studies in human brain
    • Worsley KJ, Evans AC, Marret S, Neelin P. A three-dimensional statistical analysis for CBF activation studies in human brain. J Cereb Blood Flow Metab 1992;12:900-918.
    • (1992) J Cereb Blood Flow Metab , vol.12 , pp. 900-918
    • Worsley, K.J.1    Evans, A.C.2    Marret, S.3    Neelin, P.4
  • 16
    • 44349129408 scopus 로고
    • The theory and applications of the exchange of inert gas at the lungs and tissues
    • Kety S. The theory and applications of the exchange of inert gas at the lungs and tissues. Pharmacol Rev 1951;3:1-41.
    • (1951) Pharmacol Rev , vol.3 , pp. 1-41
    • Kety, S.1
  • 17
    • 0024360873 scopus 로고
    • 15O autoradiographic method and dynamic PET
    • 15O autoradiographic method and dynamic PET. J Nucl Med 1989;30:1069-1078.
    • (1989) J Nucl Med , vol.30 , pp. 1069-1078
    • Meyer, E.1
  • 18
    • 0022601993 scopus 로고
    • Weighted integration method for local cerebral blood flow measurements with positron emission tomography
    • Carson RE, Huang SC, Green MV. Weighted integration method for local cerebral blood flow measurements with positron emission tomography. J Cereb Blood Flow Metab 1986;6:245-258.
    • (1986) J Cereb Blood Flow Metab , vol.6 , pp. 245-258
    • Carson, R.E.1    Huang, S.C.2    Green, M.V.3
  • 20
    • 0021991039 scopus 로고
    • What is the correct value for the brain-blood partition coefficient for water?
    • Herscovitch P, Raichle M. What is the correct value for the brain-blood partition coefficient for water? J Cereb Blood Flow Metab 1985;5:65-69.
    • (1985) J Cereb Blood Flow Metab , vol.5 , pp. 65-69
    • Herscovitch, P.1    Raichle, M.2
  • 21
    • 0024376394 scopus 로고
    • A preliminary evaluation of the Scanditronix PC 2048-15B brain scanner
    • Holte S, Eriksson L, Dahlbom M. A preliminary evaluation of the Scanditronix PC 2048-15B brain scanner. Eur J Nucl Med 1989;15:719-721.
    • (1989) Eur J Nucl Med , vol.15 , pp. 719-721
    • Holte, S.1    Eriksson, L.2    Dahlbom, M.3
  • 22
    • 1842361376 scopus 로고
    • Measurement of cerebral blood flow in man
    • Mathie RT, ed. Castle House Publications Ltd., Kent
    • Rowan JO, Harper AM. Measurement of cerebral blood flow in man. In: Mathie RT, ed. Blood flow measurement in man. Castle House Publications Ltd., Kent 1982;109-119.
    • (1982) Blood Flow Measurement in Man , pp. 109-119
    • Rowan, J.O.1    Harper, A.M.2
  • 23
    • 0023272297 scopus 로고
    • 15O autoradiographic method and positron emission tomography
    • 15O autoradiographic method and positron emission tomography. J Cereb Blood Flow Metab 1987;7:143-153.
    • (1987) J Cereb Blood Flow Metab , vol.7 , pp. 143-153
    • Kanno, I.1    Iida, H.2    Miura, S.3
  • 24
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformations of the projections
    • Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformations of the projections. J Comput Assist Tomogr 1983;7:42-50.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 42-50
    • Bergström, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 25
    • 0028947673 scopus 로고
    • Accurate attenuation correction despite movement during PET imaging
    • Andersson JLR, Vagnhammar BE, Schneider H. Accurate attenuation correction despite movement during PET imaging. J Nucl Med 1995;36:670-678.
    • (1995) J Nucl Med , vol.36 , pp. 670-678
    • Andersson, J.L.R.1    Vagnhammar, B.E.2    Schneider, H.3
  • 26
    • 0023220183 scopus 로고
    • Mapping human somatosensory cortex with positron emission tomography
    • Fox PT, Burton H, Raichle ME. Mapping human somatosensory cortex with positron emission tomography. J Neurosurg 1987;67:34-43.
    • (1987) J Neurosurg , vol.67 , pp. 34-43
    • Fox, P.T.1    Burton, H.2    Raichle, M.E.3
  • 28
    • 0028025096 scopus 로고
    • Imaging transient, randomly occurring neurophysiological events in single subjects with positron emission tomography: An event related count rate correlational analysis
    • Silbersweig DA, Stern E, Schnorr L, et al. Imaging transient, randomly occurring neurophysiological events in single subjects with positron emission tomography: an event related count rate correlational analysis. J Cereb Blood Flow Metab 1994;14: 771-782.
    • (1994) J Cereb Blood Flow Metab , vol.14 , pp. 771-782
    • Silbersweig, D.A.1    Stern, E.2    Schnorr, L.3
  • 29
    • 0027936315 scopus 로고
    • Dosimetry of intravenously administered oxygen-15-labeled water in man: A model based on experimental human data from 21 subjects
    • Smith T, Tong C, Lammertsma A, et al. Dosimetry of intravenously administered oxygen-15-labeled water in man: a model based on experimental human data from 21 subjects. Eur J Nucl Med 1994;21:1126-1134.
    • (1994) Eur J Nucl Med , vol.21 , pp. 1126-1134
    • Smith, T.1    Tong, C.2    Lammertsma, A.3
  • 30
    • 0028287356 scopus 로고
    • Do we really care about absorbed radiation dose?
    • Ham HR. Do we really care about absorbed radiation dose? [Letter]. Eur J Nucl Med 1994;21:696-697.
    • (1994) Eur J Nucl Med , vol.21 , pp. 696-697
    • Ham, H.R.1
  • 31
    • 0027196257 scopus 로고
    • Improved detection of focal cerebral blood flow changes using three-dimensional positron emission tomography
    • Cherry SR, Woods RP, Hoffman EJ, Mazziotta JC. Improved detection of focal cerebral blood flow changes using three-dimensional positron emission tomography. J Cereb Blood Flow Metab 1993;13:630-638.
    • (1993) J Cereb Blood Flow Metab , vol.13 , pp. 630-638
    • Cherry, S.R.1    Woods, R.P.2    Hoffman, E.J.3    Mazziotta, J.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.