메뉴 건너뛰기




Volumn 202, Issue 3, 1997, Pages 725-729

Carotid artery volume flow: In vivo measurement with time-domain- processing US

Author keywords

Carotid arteries, flow dynamics; Carotid arteries, US; comparative studies; Ultrasound (US); Ultrasound (US), Doppler studies; Ultrasound (US), technology

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTERIOVENOUS SHUNT; ARTICLE; BLOOD FLOW VELOCITY; CAROTID ARTERY FLOW; COMMON CAROTID ARTERY; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DOPPLER FLOWMETRY; IMAGE PROCESSING; INTERNAL JUGULAR VEIN; NONHUMAN; PRIORITY JOURNAL; SWINE; TIME;

EID: 0031050225     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.202.3.9051025     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 0022692830 scopus 로고
    • Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation
    • Bonnefous O, Pesqué P. Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation. Ultrason Imaging 1986; 8:73-85.
    • (1986) Ultrason Imaging , vol.8 , pp. 73-85
    • Bonnefous, O.1    Pesqué, P.2
  • 2
    • 0028439354 scopus 로고
    • Quantitative volume flow estimation using velocity profiles
    • Picot PA, Embree PM. Quantitative volume flow estimation using velocity profiles. IEEE Trans 1994; 41:340-345.
    • (1994) IEEE Trans , vol.41 , pp. 340-345
    • Picot, P.A.1    Embree, P.M.2
  • 3
    • 0024323505 scopus 로고
    • Color-flow US imaging through the analysis of speckle motion
    • Gardiner WM, Fox MD. Color-flow US imaging through the analysis of speckle motion. Radiology 1989; 172:866-868.
    • (1989) Radiology , vol.172 , pp. 866-868
    • Gardiner, W.M.1    Fox, M.D.2
  • 5
    • 0028892050 scopus 로고
    • In vitro and in vivo validation of time domain velocity and flow measurement technique
    • Maulik D, Kadaho T, Downing G, Philips C. In vitro and in vivo validation of time domain velocity and flow measurement technique. J Ultrasound Med 1995; 14:939-947.
    • (1995) J Ultrasound Med , vol.14 , pp. 939-947
    • Maulik, D.1    Kadaho, T.2    Downing, G.3    Philips, C.4
  • 7
    • 0030137796 scopus 로고    scopus 로고
    • Validation of volume flow measurements in blood vessels with quantitative color velocity imaging using a physiological model of the circulation
    • Levy DJ, Westra SJ, Sayre J, Williams R, Chang MP, Boechat MI. Validation of volume flow measurements in blood vessels with quantitative color velocity imaging using a physiological model of the circulation. Acad Radiol 1996; 3:383-388.
    • (1996) Acad Radiol , vol.3 , pp. 383-388
    • Levy, D.J.1    Westra, S.J.2    Sayre, J.3    Williams, R.4    Chang, M.P.5    Boechat, M.I.6
  • 8
    • 0028354183 scopus 로고
    • Use of a Doppler microguidewire for intravascular blood flow measurements: A validation study for potential neurological endovascular applications
    • Chaloupka JC, Viñuela F, Kimme-Smith C, Robert J, Duckwiler GR. Use of a Doppler microguidewire for intravascular blood flow measurements: a validation study for potential neurological endovascular applications. AJNR 1994; 15:509-517.
    • (1994) AJNR , vol.15 , pp. 509-517
    • Chaloupka, J.C.1    Viñuela, F.2    Kimme-Smith, C.3    Robert, J.4    Duckwiler, G.R.5
  • 9
    • 0027282729 scopus 로고
    • Volume flow measurements with a transit time flowmeter: An in vivo and in vitro variability and validation study
    • Lundell A, Bergqvist D, Mattson E, Nilsson B. Volume flow measurements with a transit time flowmeter: an in vivo and in vitro variability and validation study. Clin Physiol 1993; 13:547-557.
    • (1993) Clin Physiol , vol.13 , pp. 547-557
    • Lundell, A.1    Bergqvist, D.2    Mattson, E.3    Nilsson, B.4
  • 10
    • 0028852573 scopus 로고
    • The ultrasonic transit-time flowmeter: An accurate method for measuring renal blood flow in the rat
    • Welch WJ, Deng X, Snellen H, Wilcox CS. The ultrasonic transit-time flowmeter: an accurate method for measuring renal blood flow in the rat. Am J Physiol 1995; 268:175-178.
    • (1995) Am J Physiol , vol.268 , pp. 175-178
    • Welch, W.J.1    Deng, X.2    Snellen, H.3    Wilcox, C.S.4
  • 13
    • 0021322915 scopus 로고
    • Cerebral blood flow in the newborn infant: Comparison of Doppler ultrasound and 133xenon clearance
    • Greisen G, Johansen K, Ellison PH, Frederiksen PS, Mali J, Friis-Hansen B. Cerebral blood flow in the newborn infant: comparison of Doppler ultrasound and 133xenon clearance. J Pediatr 1984; 104:411-418.
    • (1984) J Pediatr , vol.104 , pp. 411-418
    • Greisen, G.1    Johansen, K.2    Ellison, P.H.3    Frederiksen, P.S.4    Mali, J.5    Friis-Hansen, B.6
  • 14
    • 0026512065 scopus 로고
    • Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: Evaluation of normal subjects and patients with arteriovenous malformations
    • Marks MP, Pelc NJ, Ross MR, Enzman DR. Determination of cerebral blood flow with a phase-contrast cine MR imaging technique: evaluation of normal subjects and patients with arteriovenous malformations. Radiology 1992; 182:467-476.
    • (1992) Radiology , vol.182 , pp. 467-476
    • Marks, M.P.1    Pelc, N.J.2    Ross, M.R.3    Enzman, D.R.4
  • 15
    • 0028008854 scopus 로고
    • Relationship between brain blood flow and carotid arterial flow in the sheep fetus
    • Van Bel F, Roman C, Klautz RJ, Teitel DF, Rudolph AM. Relationship between brain blood flow and carotid arterial flow in the sheep fetus. Pediatr Res 1994; 35:329-333.
    • (1994) Pediatr Res , vol.35 , pp. 329-333
    • Van Bel, F.1    Roman, C.2    Klautz, R.J.3    Teitel, D.F.4    Rudolph, A.M.5
  • 16
    • 0027404236 scopus 로고
    • Pediatric intracranial vascular malformations: Evaluation of treatment results with color Doppler US - Work in progress
    • Westra SJ, Curran JG, Duckwiler GR, et al. Pediatric intracranial vascular malformations: evaluation of treatment results with color Doppler US - work in progress. Radiology 1993; 186:775-783.
    • (1993) Radiology , vol.186 , pp. 775-783
    • Westra, S.J.1    Curran, J.G.2    Duckwiler, G.R.3
  • 17
    • 0022272101 scopus 로고
    • Quantitative flow measurements with Doppler ultrasound: Techniques, accuracy, and limitations
    • Burns PN, Jaffe CC. Quantitative flow measurements with Doppler ultrasound: techniques, accuracy, and limitations. Radiol Clin North Am 1985; 23:641-657.
    • (1985) Radiol Clin North Am , vol.23 , pp. 641-657
    • Burns, P.N.1    Jaffe, C.C.2
  • 18
    • 0022591487 scopus 로고
    • Absolute flow measurements using pulsed Doppler US
    • Walter JP, McGahan JP, Lantz BMT. Absolute flow measurements using pulsed Doppler US. Radiology 1986; 159:545-548.
    • (1986) Radiology , vol.159 , pp. 545-548
    • Walter, J.P.1    McGahan, J.P.2    Lantz, B.M.T.3
  • 19
    • 0025058754 scopus 로고
    • Doppler US. I. Basic principles, instrumentation, and pitfalls
    • Taylor KJW, Holland S. Doppler US. I. Basic principles, instrumentation, and pitfalls. Radiology 1990; 174:297-307.
    • (1990) Radiology , vol.174 , pp. 297-307
    • Taylor, K.J.W.1    Holland, S.2
  • 20
    • 0025334062 scopus 로고
    • Intracranial blood flow quantification with duplex Doppler and color Doppler flow US
    • Taylor GA, Short BL, Walker LK, Traytsman RJ. Intracranial blood flow quantification with duplex Doppler and color Doppler flow US. Radiology 1990; 176: 231-236.
    • (1990) Radiology , vol.176 , pp. 231-236
    • Taylor, G.A.1    Short, B.L.2    Walker, L.K.3    Traytsman, R.J.4
  • 21
    • 0025356924 scopus 로고
    • Major pitfalls in Doppler investigations with particular reference to the cerebral vascular system
    • Winkler P, Helmke K. Major pitfalls in Doppler investigations with particular reference to the cerebral vascular system. Pediatr Radiol 1990; 20:219-228.
    • (1990) Pediatr Radiol , vol.20 , pp. 219-228
    • Winkler, P.1    Helmke, K.2
  • 23
    • 0026572869 scopus 로고
    • Effect on pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound
    • Eriksen M. Effect on pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound. Med Biol Eng Comput 1992; 30:46-50.
    • (1992) Med Biol Eng Comput , vol.30 , pp. 46-50
    • Eriksen, M.1
  • 24
    • 0026150561 scopus 로고
    • Color velocity imaging: Introduction to a new ultrasound technology
    • Tegeler CH, Kremkau FW, Hitchings LP. Color velocity imaging: introduction to a new ultrasound technology. J Neuroimaging 1991; 1:85-90.
    • (1991) J Neuroimaging , vol.1 , pp. 85-90
    • Tegeler, C.H.1    Kremkau, F.W.2    Hitchings, L.P.3
  • 25
    • 0030029215 scopus 로고    scopus 로고
    • Clinical cerebrovascular applications of arterial ultrasound volume flow rate estimates
    • Knappertz VA, Tegeler CH, Myers LG. Clinical cerebrovascular applications of arterial ultrasound volume flow rate estimates. J Neuroimaging 1996; 6:1-7.
    • (1996) J Neuroimaging , vol.6 , pp. 1-7
    • Knappertz, V.A.1    Tegeler, C.H.2    Myers, L.G.3
  • 26
    • 0001719855 scopus 로고
    • Ultrasonographic quantitative flow volumetry of the carotid arteries: Initial experience with a color flow M-mode system
    • Eicke BM, Tegeler CH. Ultrasonographic quantitative flow volumetry of the carotid arteries: initial experience with a color flow M-mode system. Cerebrovasc Dis 1995; 5:145-149.
    • (1995) Cerebrovasc Dis , vol.5 , pp. 145-149
    • Eicke, B.M.1    Tegeler, C.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.