-
3
-
-
1842407016
-
-
Personal communication
-
Dawson D 1995 Personal communication
-
(1995)
-
-
Dawson, D.1
-
4
-
-
0343412547
-
An angle-dependent albedo for fast neutron-reflection calculations
-
French R L and Wells M B 1964 An angle-dependent albedo for fast neutron-reflection calculations Nucl. Sci. Eng. 19 441
-
(1964)
Nucl. Sci. Eng.
, vol.19
, pp. 441
-
-
French, R.L.1
Wells, M.B.2
-
5
-
-
0343869192
-
Estimation of neutron and gamma radiation doses in the entrance mazes of SL75-20 linear accelerator treatment rooms
-
Kersey R W 1979 Estimation of neutron and gamma radiation doses in the entrance mazes of SL75-20 linear accelerator treatment rooms Medicamundi 24 151-5
-
(1979)
Medicamundi
, vol.24
, pp. 151-155
-
-
Kersey, R.W.1
-
8
-
-
0025903594
-
Evaluation of neutron dose equivalent levels at the maze entrance of medical accelerator treatment rooms
-
McGinley P H and Butker E K 1991 Evaluation of neutron dose equivalent levels at the maze entrance of medical accelerator treatment rooms Med. Phys. 18 279-81
-
(1991)
Med. Phys.
, vol.18
, pp. 279-281
-
-
McGinley, P.H.1
Butker, E.K.2
-
9
-
-
0029048218
-
A method for calculating the dose due to capture gamma rays in accelerator mazes
-
McGinley P H, Miner M S and Mitchum M L 1995 A method for calculating the dose due to capture gamma rays in accelerator mazes Phys. Med. Biol. 40 1467-73
-
(1995)
Phys. Med. Biol.
, vol.40
, pp. 1467-1473
-
-
McGinley, P.H.1
Miner, M.S.2
Mitchum, M.L.3
-
10
-
-
0003511916
-
Neutron contamination from medical electron accelerators
-
Bethesda, MD: NCRP
-
NCRP 1984 Neutron contamination from medical electron accelerators NCRP Report 79 (Bethesda, MD: NCRP).
-
(1984)
NCRP Report
, vol.79
-
-
-
11
-
-
0021932208
-
Radation protection aspects of a new high-energy linear accelerator
-
O'Brien P, Michaels H B, Gillies B, Aldrich J E and Andrew J W 1985 Radation protection aspects of a new high-energy linear accelerator Med. Phys. 12 101-7
-
(1985)
Med. Phys.
, vol.12
, pp. 101-107
-
-
O'Brien, P.1
Michaels, H.B.2
Gillies, B.3
Aldrich, J.E.4
Andrew, J.W.5
-
12
-
-
0019476434
-
Use of a neutron remmeter to measure leakage neutrons from medical electron accelerators
-
Rogers D W O and Van Dyk G 1981 Use of a neutron remmeter to measure leakage neutrons from medical electron accelerators Med. Phys. 8 163-6
-
(1981)
Med. Phys.
, vol.8
, pp. 163-166
-
-
Rogers, D.W.O.1
Van Dyk, G.2
-
13
-
-
0022485431
-
Measurement and calculation of neutron leakage from a medical electron accelerator
-
Uwamino Y, Nakamura T, Ohkubo T and Hara A 1986 Measurement and calculation of neutron leakage from a medical electron accelerator Med. Phys. 13 374-84
-
(1986)
Med. Phys.
, vol.13
, pp. 374-384
-
-
Uwamino, Y.1
Nakamura, T.2
Ohkubo, T.3
Hara, A.4
|