Validation of reflectance pulse oximetry: An evaluation of a new sensor in piglets

Author keywords

arterial oxygen saturation; pig; reflectance pulse oximetry; validation

Indexed keywords

BLOOD; BLOOD VESSELS; CATHETERS; LIGHT EMITTING DIODES; OXIMETERS; OXYGEN; PHOTODETECTORS;

EID: 0031042937     PISSN: 07481977     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1007332105965     Document Type: Article
Times cited : (13)

References (23)
  • 6
    • 0027199992 scopus 로고
    • Validation of arterial oxygen saturation measurements in utero using pulse oximetry
    • Harris AP, Sendak MJ, Chung DC, Richardson CA. Validation of arterial oxygen saturation measurements in utero using pulse oximetry. Am J Perinat 1993; 10: 250-254
    • (1993) Am J Perinat , vol.10 , pp. 250-254
    • Harris, A.P.1    Sendak, M.J.2    Chung, D.C.3    Richardson, C.A.4
  • 8
    • 0342735101 scopus 로고
    • Arterial oxygen saturation in the fetus: An experimental animal study with pulse oximetry
    • Nijland R. Arterial oxygen saturation in the fetus: an experimental animal study with pulse oximetry. Thesis 1995, Nijmegen,The Netherlands
    • (1995) Thesis
    • Nijland, R.1
  • 9
    • 0030152126 scopus 로고    scopus 로고
    • Reflectance pulse oximetry in fetal lambs: Subcutaneous vessels and vasoconstriction affect its reliability
    • Nijland R, Jongsma HW, Verbruggen IM, Nijhuis JG. Reflectance pulse oximetry in fetal lambs: subcutaneous vessels and vasoconstriction affect its reliability. J Clin Momt 1996; 12: 225-230
    • (1996) J Clin Momt , vol.12 , pp. 225-230
    • Nijland, R.1    Jongsma, H.W.2    Verbruggen, I.M.3    Nijhuis, J.G.4
  • 11
    • 0026335383 scopus 로고
    • Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry
    • Schmitt JM. Simple photon diffusion analysis of the effects of multiple scattering on pulse oximetry. IEEE Trans Biomed Eng 1991; 38: 1194-1203
    • (1991) IEEE Trans Biomed Eng , vol.38 , pp. 1194-1203
    • Schmitt, J.M.1
  • 13
    • 0028938140 scopus 로고
    • Reflectance pulse oximetry (RPOX): Two sensors compared
    • part 2, 365
    • Nijland R, Jongsma HW, Nijhuis JG. Reflectance pulse oximetry (RPOX): two sensors compared. Am J Obstet Gynecol 1995; 172, part 2, 365
    • (1995) Am J Obstet Gynecol , vol.172
    • Nijland, R.1    Jongsma, H.W.2    Nijhuis, J.G.3
  • 14
    • 0018228183 scopus 로고
    • The skin of domestic mammals as a model for the human skin, with special reference to the domestic pig
    • Meyer W, Schwarz, Neurad K. The skin of domestic mammals as a model for the human skin, with special reference to the domestic pig. Curr Probl Dermatol 1978; 7: 39-52
    • (1978) Curr Probl Dermatol , vol.7 , pp. 39-52
    • Meyer, W.1    Schwarz2    Neurad, K.3
  • 15
    • 84995192433 scopus 로고
    • The accuracy of a fiberoptic oximeter over a wide range of arterial oxygen saturation values in piglets
    • Nijland R, Jongsma HW, Nijhuis JG, Oeseburg B. The accuracy of a fiberoptic oximeter over a wide range of arterial oxygen saturation values in piglets. Acta Anaesth Scand 1995; 39: suppl 107: 71-76
    • (1995) Acta Anaesth Scand , vol.39 , Issue.107 SUPPL. , pp. 71-76
    • Nijland, R.1    Jongsma, H.W.2    Nijhuis, J.G.3    Oeseburg, B.4
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i: 307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 17
    • 0023622954 scopus 로고
    • Gottesfeld I, Smgh S, LaCorte MA, Parnell A Jr, Walker P. Noninvasive pulse oximetry in children with cyanotic congenital heart disease
    • Boxer RA, Gottesfeld I, Smgh S, LaCorte MA, Parnell A Jr, Walker P. Noninvasive pulse oximetry in children with cyanotic congenital heart disease. Crit Care Med 1987; 15: 1062-1064
    • (1987) Crit Care Med , vol.15 , pp. 1062-1064
    • Boxer, R.A.1
  • 19
    • 0028341399 scopus 로고
    • Artifacts in fetal pulse oximetry: Incomplete sensor-to-skin contact
    • GardosiJO, Damianou D, Schräm CMH. Artifacts in fetal pulse oximetry: Incomplete sensor-to-skin contact. Am J Obstet Gynecol 1994; 170: 1169-1173
    • (1994) Am J Obstet Gynecol , vol.170 , pp. 1169-1173
    • Gardosi, J.O.1    Damianou, D.2    Schräm, C.M.H.3
  • 20
    • 0028278292 scopus 로고
    • Artifacts in fetal pulse oximetry: Nonarterial pulsatile signals
    • Schräm CMH, GardosiJO. Artifacts in fetal pulse oximetry: Nonarterial pulsatile signals. Am J Obstet Gynecol 1994; 170: 1174-1177
    • (1994) Am J Obstet Gynecol , vol.170 , pp. 1174-1177
    • Schräm, C.M.H.1    Gardosi, J.O.2
  • 22
    • 0026059529 scopus 로고
    • In vitro investigation of factors affecting pulse oximetry
    • De Kock JP, Tarassenko L. In vitro investigation of factors affecting pulse oximetry. J Biomed Eng 1991; 13: 61-66
    • (1991) J Biomed Eng , vol.13 , pp. 61-66
    • De Kock, J.P.1    Tarassenko, L.2
  • 23
    • 33749715981 scopus 로고    scopus 로고
    • Technical issues of noninvasive fetal oxygen saturation monitoring using the Nellcor N-400. Nellcor Puritan Bennett Inc. 1995, Pleasanton, CA 94588, USA
    • Technical issues of noninvasive fetal oxygen saturation monitoring using the Nellcor N-400. Nellcor Puritan Bennett Inc. 1995, Pleasanton, CA 94588, USA


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.