메뉴 건너뛰기




Volumn 44, Issue 1, 1997, Pages 70-76

The inaccuracy of eubicek's one-cylinder model in thoracic impedance cardiography

Author keywords

Electrical impedance cardiography; Index terms Cylinder; Modeling; Stroke volume

Indexed keywords

ADULT; ARTICLE; HEART STROKE VOLUME; HUMAN; HUMAN EXPERIMENT; IMPEDANCE CARDIOGRAPHY; MALE; MODEL; NORMAL HUMAN; STATISTICAL ANALYSIS; THORAX;

EID: 0031032233     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.553714     Document Type: Article
Times cited : (14)

References (24)
  • 2
    • 33748171785 scopus 로고
    • "Noninvasive technique for measurement of cardiac output by means of electrical impedance," in
    • B. B. Sramek, "Noninvasive technique for measurement of cardiac output by means of electrical impedance," in Proc. 5th Int. Conf. Electrical Bioimpedance, Tokyo, Japan, 1981, p. 3942.
    • (1981) Proc. , vol.5 , pp. 3942
    • Sramek, B.B.1
  • 3
    • 0022980897 scopus 로고
    • "A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale,"
    • D. P Bernstein, "A new stroke volume equation for thoracic electrical bioimpedance: Theory and rationale," Crit. Care Med., vol. 14, pp. 904-909, 1986.
    • (1986) Crit. Care Med. , vol.14 , pp. 904-909
    • Bernstein, D.P.1
  • 4
    • 0019956944 scopus 로고
    • "Stroke volume measurement by impedance cardiography using a formula based on the Az waveform,"
    • G. Granerus and R. Elg, "Stroke volume measurement by impedance cardiography using a formula based on the Az waveform," Clin. Phys. Physiol. Meas., vol. 3, pp. 131-139, 1982.
    • (1982) Clin. Phys. Physiol. Meas. , vol.3 , pp. 131-139
    • Granerus, G.1    Elg, R.2
  • 5
    • 0025017250 scopus 로고
    • "Impedance cardiography fails to measure accurately left ventricular ejection fraction,"
    • D. S. Miles, R. W. Gotshall, J. D. Quinones, D. W. Wulfeck, and R. D. Kreitzer, "Impedance cardiography fails to measure accurately left ventricular ejection fraction," Crit. Care Med., vol. 18, pp. 221-228, 1990.
    • (1990) Crit. Care Med. , vol.18 , pp. 221-228
    • Miles, D.S.1    Gotshall, R.W.2    Quinones, J.D.3    Wulfeck, D.W.4    Kreitzer, R.D.5
  • 6
    • 0017813351 scopus 로고
    • "Impedance cardiography,"
    • J. C. Miller and S. M. Horvath, "Impedance cardiography," Psychophysiol, vol. 5, pp. 80-90, 1978.
    • (1978) Psychophysiol , vol.5 , pp. 80-90
    • Miller, J.C.1    Horvath, S.M.2
  • 7
    • 0027303986 scopus 로고
    • "Impedance cardiography for cardiac output estimation in pacemaker patients: Review of the literature,"
    • I. Ovsyshcher and S. Furman, "Impedance cardiography for cardiac output estimation in pacemaker patients: Review of the literature," Pace, vol. 16, pp. 1412-1420, 1993.
    • (1993) Pace , vol.16 , pp. 1412-1420
    • Ovsyshcher, I.1    Furman, S.2
  • 9
    • 0029239605 scopus 로고
    • "Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models,"
    • L. Wang and R. P. Patterson, "Multiple sources of the impedance cardiogram based on 3-D finite difference human thorax models," IEEE Trans. Biomed. Eng., vol. 42, no. 2, pp. 141-148, 1995.
    • (1995) IEEE Trans. Biomed. Eng. , vol.42 , Issue.2 , pp. 141-148
    • Wang, L.1    Patterson, R.P.2
  • 19
    • 0028876909 scopus 로고
    • "The influence of alternating current frequency on flow related admittance changes of blood: A concept for improvement of impedance cardiography,"
    • P. M. J. M. de Vries, J. W. G. Langendijk, and P. M. Kouw, "The influence of alternating current frequency on flow related admittance changes of blood: a concept for improvement of impedance cardiography," Physiol Meas., vol. 16, pp. 1-7, 1995.
    • (1995) Physiol Meas. , vol.16 , pp. 1-7
    • De Vries, P.M.J.M.1    Langendijk, J.W.G.2    Kouw, P.M.3
  • 21
    • 0022026327 scopus 로고    scopus 로고
    • "The contribution of vessel volume change and blood resistivity change to the electrical impedance pulse,"
    • T. M. R. Shankar, J. O. Webster, and S.-Y. Shao, "The contribution of vessel volume change and blood resistivity change to the electrical impedance pulse," IEEE Trans. Biomed. Eng., vol. BME32, pp. 192-198, 19S5.
    • IEEE Trans. Biomed. Eng., Vol. BME , vol.32 , pp. 192-198
    • Shankar, T.M.R.1    Webster, J.O.2    Shao, S.-Y.3
  • 22
    • 0022130871 scopus 로고
    • "Sources of the thoracic cardiogenic electrical impedance signal as determined by a model,"
    • 'R. P. Patterson, "Sources of the thoracic cardiogenic electrical impedance signal as determined by a model," Med., Biol. Eng., Comput., vol. 23, pp. 411-417, 1985.
    • (1985) Med., Biol. Eng., Comput. , vol.23 , pp. 411-417
    • Patterson, R.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.