메뉴 건너뛰기




Volumn 82, Issue 1, 1997, Pages 172-181

Respiratory transfer impedance between 8 and 384 H z in guinea pigs before and after bronchial challenge

Author keywords

forced oscillation technique; noninvasive; respiratory compliance; respiratory inertance; respiratory resistance

Indexed keywords

METHACHOLINE;

EID: 0031031988     PISSN: 87507587     EISSN: None     Source Type: Journal    
DOI: 10.1152/jappl.1997.82.1.172     Document Type: Article
Times cited : (2)

References (30)
  • 1
    • 84960644136 scopus 로고
    • Mechanics of respiration in unanesthetized guinea pigs
    • Amdur, M. O., and J. Mead. Mechanics of respiration in unanesthetized guinea pigs. Am. J. Physiol. 192: 364-368, 1958.
    • (1958) Am. J. Physiol. , vol.192 , pp. 364-368
    • Amdur, M.O.1    Mead, J.2
  • 3
    • 0001618992 scopus 로고
    • On the propagation of sound waves in cylindrical conduit
    • Benade, A. H. On the propagation of sound waves in cylindrical conduit. J. Acoust. Soc. Am. 22: 563-564, 1990.
    • (1990) J. Acoust. Soc. Am. , vol.22 , pp. 563-564
    • Benade, A.H.1
  • 5
    • 0017588312 scopus 로고
    • Pulmonary mechanics in normal rats
    • Diamond, L., and M. O'Donnell. Pulmonary mechanics in normal rats. J. Appl. Physiol. 43: 942-948, 1977.
    • (1977) J. Appl. Physiol. , vol.43 , pp. 942-948
    • Diamond, L.1    O'Donnell, M.2
  • 7
    • 0023196070 scopus 로고
    • Low-frequency respiratory mechanical impedance in the rat
    • Hantos, Z., B. Daroczy, B. Suki, and S. Nagy. Low-frequency respiratory mechanical impedance in the rat. J. Appl. Physiol. 63: 36-43, 1987.
    • (1987) J. Appl. Physiol. , vol.63 , pp. 36-43
    • Hantos, Z.1    Daroczy, B.2    Suki, B.3    Nagy, S.4
  • 9
    • 0015966556 scopus 로고
    • Tests of ventilatory function for use in long-term animal studies
    • Hiett, D. M. Tests of ventilatory function for use in long-term animal studies. Br. J. Ind. Med. 31: 53-58, 1974.
    • (1974) Br. J. Ind. Med. , vol.31 , pp. 53-58
    • Hiett, D.M.1
  • 11
    • 15144360599 scopus 로고
    • Respiratory impedance by discrete frequency or broadband input signal
    • Jackson, A. C., and R. H. Habib. Respiratory impedance by discrete frequency or broadband input signal. Eur. Respir. Rev. 1: 174-177, 1991.
    • (1991) Eur. Respir. Rev. , vol.1 , pp. 174-177
    • Jackson, A.C.1    Habib, R.H.2
  • 12
    • 0026079311 scopus 로고
    • Physiological basis for resonant frequencies in respiratory system impedances in dogs
    • Jackson, A. C., and K. R. Lutchen. Physiological basis for resonant frequencies in respiratory system impedances in dogs. J. Appl. Physiol. 70: 1051-1058, 1991.
    • (1991) J. Appl. Physiol. , vol.70 , pp. 1051-1058
    • Jackson, A.C.1    Lutchen, K.R.2
  • 13
    • 0018634866 scopus 로고
    • A technique for measuring frequency response of pressure, volume, and flow transducers
    • Jackson, A. C., and A. Vinegar. A technique for measuring frequency response of pressure, volume, and flow transducers. J. Appl. Physiol. 47: 462-467, 1979.
    • (1979) J. Appl. Physiol. , vol.47 , pp. 462-467
    • Jackson, A.C.1    Vinegar, A.2
  • 14
    • 0019953495 scopus 로고
    • Oscillatory mechanics of the respiratory system in normal rats
    • Jackson, A. C., and J. W. Watson. Oscillatory mechanics of the respiratory system in normal rats. Respir. Physiol. 48: 309-322, 1982.
    • (1982) Respir. Physiol. , vol.48 , pp. 309-322
    • Jackson, A.C.1    Watson, J.W.2
  • 15
    • 0020469966 scopus 로고
    • Thermal decomposition products of PVC plastics: Effects of guinea pig lung mechanics and pulmonary mixed function oxidase activity
    • Jaeger, R. J., W. A. Skornik, and R. Heimann. Thermal decomposition products of PVC plastics: effects of guinea pig lung mechanics and pulmonary mixed function oxidase activity. Am. Ind. Hyg. Assoc. J. 43: 900-907, 1982.
    • (1982) Am. Ind. Hyg. Assoc. J. , vol.43 , pp. 900-907
    • Jaeger, R.J.1    Skornik, W.A.2    Heimann, R.3
  • 16
    • 0026883702 scopus 로고
    • Confidence bounds on respiratory mechanical properties estimated from transfer impedance versus input impedance in humans versus dogs
    • Lutchen, K. R. Confidence bounds on respiratory mechanical properties estimated from transfer impedance versus input impedance in humans versus dogs. IEEE Trans. Biomed. Eng. 39: 644-651, 1992.
    • (1992) IEEE Trans. Biomed. Eng. , vol.39 , pp. 644-651
    • Lutchen, K.R.1
  • 17
    • 0027417984 scopus 로고
    • Impact of frequency range and input impedance on airway-tissue separation implied from transfer impedance
    • Lutchen, K. R., J. R. Everett, and A. C. Jackson. Impact of frequency range and input impedance on airway-tissue separation implied from transfer impedance. J. Appl. Physiol. 74: 1089-1099, 1993.
    • (1993) J. Appl. Physiol. , vol.74 , pp. 1089-1099
    • Lutchen, K.R.1    Everett, J.R.2    Jackson, A.C.3
  • 18
    • 0023236512 scopus 로고
    • Reliability of parameter estimates from models applied to respiratory impedance data
    • Lutchen, K. R., and A. C. Jackson. Reliability of parameter estimates from models applied to respiratory impedance data. J. Appl. Physiol. 62: 403-410, 1987.
    • (1987) J. Appl. Physiol. , vol.62 , pp. 403-410
    • Lutchen, K.R.1    Jackson, A.C.2
  • 19
    • 0022812784 scopus 로고
    • Statistical measures of parameter estimates from models fit to respiratory impedance data: Emphasis on joint variables
    • Lutchen, K. R., and A. C. Jackson. Statistical measures of parameter estimates from models fit to respiratory impedance data: emphasis on joint variables. IEEE Trans. Biomed. Eng. BME-33: 1000-1010, 1986.
    • (1986) IEEE Trans. Biomed. Eng. , vol.BME-33 , pp. 1000-1010
    • Lutchen, K.R.1    Jackson, A.C.2
  • 20
    • 0000848736 scopus 로고
    • Control of respiratory frequency
    • Mead, J. Control of respiratory frequency. J. Appl. Physiol. 15: 325-336, 1960.
    • (1960) J. Appl. Physiol. , vol.15 , pp. 325-336
    • Mead, J.1
  • 21
    • 0014514840 scopus 로고
    • Contribution of compliance of airways to frequency-dependent behavior of lungs
    • Mead, J. Contribution of compliance of airways to frequency-dependent behavior of lungs. J. Appl. Physiol. 26: 670-673, 1969.
    • (1969) J. Appl. Physiol. , vol.26 , pp. 670-673
    • Mead, J.1
  • 22
    • 0028226808 scopus 로고
    • Effects of pentobarbital and halothane anesthesia on the respiratory transfer impedance of
    • Oostveen, E., and A. Zwart. Effects of pentobarbital and halothane anesthesia on the respiratory transfer impedance of rats. Eur. Respir. Rev. 4: 172-177, 1994.
    • (1994) Rats. Eur. Respir. Rev. , vol.4 , pp. 172-177
    • Oostveen, E.1    Zwart, A.2
  • 23
    • 0026733486 scopus 로고
    • Respiratory transfer impedance and derived mechanical properties of conscious rats
    • Oostveen, E., A. Zwart, R. Peslin, and C. Duvivier. Respiratory transfer impedance and derived mechanical properties of conscious rats. J. Appl. Physiol. 73: 1598-1607, 1992.
    • (1992) J. Appl. Physiol. , vol.73 , pp. 1598-1607
    • Oostveen, E.1    Zwart, A.2    Peslin, R.3    Duvivier, C.4
  • 25
    • 0018354187 scopus 로고
    • Pulmonary effect of acute and chronic antigen exposure of immunized guinea pigs
    • Pare, P. D., M. C. Michoud, R. C. Boucher, and J. C. Hogg. Pulmonary effect of acute and chronic antigen exposure of immunized guinea pigs. J. Appl. Physiol. 46: 346-353, 1979.
    • (1979) J. Appl. Physiol. , vol.46 , pp. 346-353
    • Pare, P.D.1    Michoud, M.C.2    Boucher, R.C.3    Hogg, J.C.4
  • 26
    • 0022493460 scopus 로고
    • Respiratory transfer impedances with pressure input at the mouth and chest
    • Peslin, R., C. Gallina, and C. Duvivier. Respiratory transfer impedances with pressure input at the mouth and chest. J. Appl. Physiol. 61: 81-86, 1986.
    • (1986) J. Appl. Physiol. , vol.61 , pp. 81-86
    • Peslin, R.1    Gallina, C.2    Duvivier, C.3
  • 27
    • 0025135479 scopus 로고
    • Improved frequency response of pneumotachometers by digital compensation
    • Renzi, P. E., C. A. Giurdanella, and A. C. Jackson. Improved frequency response of pneumotachometers by digital compensation. J. Appl. Physiol. 68: 382-386, 1990.
    • (1990) J. Appl. Physiol. , vol.68 , pp. 382-386
    • Renzi, P.E.1    Giurdanella, C.A.2    Jackson, A.C.3
  • 28
    • 0025372830 scopus 로고
    • Breathing and lung mechanics in hamsters: Effect of pentobarbital anesthesia
    • Skornik, W. A., and J. D. Brain. Breathing and lung mechanics in hamsters: effect of pentobarbital anesthesia. J. Appl. Physiol. 68: 2536-2541, 1990.
    • (1990) J. Appl. Physiol. , vol.68 , pp. 2536-2541
    • Skornik, W.A.1    Brain, J.D.2
  • 29
    • 0019416055 scopus 로고
    • Pulmonary mechanics in guinea pigs: Repeated measurements using a nonsurgical computerized method
    • Skornik, W. A., R. Heimann, and R. J. Jaeger. Pulmonary mechanics in guinea pigs: repeated measurements using a nonsurgical computerized method. Toxicol. Appl. Pharmacol. 59: 314-323, 1981.
    • (1981) Toxicol. Appl. Pharmacol. , vol.59 , pp. 314-323
    • Skornik, W.A.1    Heimann, R.2    Jaeger, R.J.3
  • 30
    • 0022452296 scopus 로고
    • Effect of lung volume on pulmonary mechanics in guinea pigs
    • Watson, J. W., A. C. Jackson, and J. M. Drazen. Effect of lung volume on pulmonary mechanics in guinea pigs. J. Appl. Physiol. 61: 304-311, 1986.
    • (1986) J. Appl. Physiol. , vol.61 , pp. 304-311
    • Watson, J.W.1    Jackson, A.C.2    Drazen, J.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.