메뉴 건너뛰기




Volumn 72, Issue 1, 1997, Pages 141-146

Automatic filter placement device for Region of Interest (ROI) Fluoroscopy

Author keywords

dose; fluoroscopy; operational topic; x rays

Indexed keywords

ARTICLE; FLUOROSCOPY; PRIORITY JOURNAL; RADIATION EXPOSURE; RADIATION HAZARD; RADIATION INJURY; RADIATION PROTECTION;

EID: 0031030371     PISSN: 00179078     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004032-199701000-00020     Document Type: Article
Times cited : (8)

References (7)
  • 1
    • 0020603628 scopus 로고
    • Assessment of patient exposure for barium enema examinations
    • Bednarek, D. R.; Rudin, S.; Wong, R. Assessment of patient exposure for barium enema examinations. Investigative Radiol.18:453-458; 1983.
    • (1983) Investigative Radiol. , vol.18 , pp. 453-458
    • Bednarek, D.R.1    Rudin, S.2    Wong, R.3
  • 2
    • 1842297206 scopus 로고
    • Method for measuring the total dose area product during region of interest (ROI) fluoroscopy
    • Kezerashvili, M.; Rudin, S.; Bednarek, D. R. Method for measuring the total dose area product during region of interest (ROI) fluoroscopy (abstract). Med. Phys. 22:947; 1995.
    • (1995) Med. Phys. , vol.22 , pp. 947
    • Kezerashvili, M.1    Rudin, S.2    Bednarek, D.R.3
  • 3
    • 0344159596 scopus 로고
    • Contrast improvement of iodine using a gadolinium filter for application to region of interest (ROI) fluoroscopy
    • Massoumzadeh, P.; Rudin, S.; Bednarek, D. R. Contrast improvement of iodine using a gadolinium filter for application to region of interest (ROI) fluoroscopy (abstract). Med. Phys. 22:972; 1995.
    • (1995) Med. Phys. , vol.22 , pp. 972
    • Massoumzadeh, P.1    Rudin, S.2    Bednarek, D.R.3
  • 4
    • 0026806132 scopus 로고
    • Region of interest fluoroscopy
    • Rudin, S.; Bednarek, D. R. Region of interest fluoroscopy. Med. Phys. 19:1183-1189; 1992.
    • (1992) Med. Phys. , vol.19 , pp. 1183-1189
    • Rudin, S.1    Bednarek, D.R.2
  • 5
    • 0027839574 scopus 로고
    • Comparison of filter material and design for use in ROI angiography. Medical Imaging 1993
    • Rudin, S.; Bednarek, D. R. Comparison of filter material and design for use in ROI angiography. Medical Imaging 1993: Phys. Med. Imaging, SPIE 1896:354-364; 1993.
    • (1993) Phys. Med. Imaging, SPIE , vol.1896 , pp. 354-364
    • Rudin, S.1    Bednarek, D.R.2
  • 7
    • 26844463997 scopus 로고
    • Response to J. Walmsley's comments on "The x-ray fovea, a device for reducing x-ray dose in fluoroscopy."
    • Wilson, D.; Rzeszotarski, M. S. Response to J. Walmsley's comments on "The x-ray fovea, a device for reducing x-ray dose in fluoroscopy." Med. Phys. 21:1887; 1994.
    • (1994) Med. Phys. , vol.21 , pp. 1887
    • Wilson, D.1    Rzeszotarski, M.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.