메뉴 건너뛰기




Volumn 21, Issue 1, 1997, Pages 136-144

Implementation and validation of a fully automatic system for intra- and interindividual registration of PET brain scans

Author keywords

Atlas and atlases; Brain, anatomy; Emission computed tomography; Emission computed tomography, physics; Image registration

Indexed keywords

ATLAS AND ATLAS; AUTOMATIC METHOD; AUTOMATIC SYSTEMS; BRAIN ANATOMY; BRAIN SCAN; COORDINATE SPACE; EMISSION COMPUTED TOMOGRAPHY; EMISSION COMPUTED TOMOGRAPHY, PHYSIC; IMAGES REGISTRATION;

EID: 0031027875     PISSN: 03638715     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004728-199701000-00027     Document Type: Article
Times cited : (57)

References (35)
  • 1
    • 0021930013 scopus 로고
    • A stereotactic method of anatomical localization for positron emission tomography
    • Fox PT, Perlmutter JS, Raichle ME. A stereotactic method of anatomical localization for positron emission tomography. J Comput Assist Tomogr 1985;9:141-53.
    • (1985) J Comput Assist Tomogr , vol.9 , pp. 141-153
    • Fox, P.T.1    Perlmutter, J.S.2    Raichle, M.E.3
  • 2
    • 0028287162 scopus 로고
    • Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space
    • Collins L, Neelin P, Terrence P, Evans A. Automatic 3D intersubject registration of MR volumetric data in standardized Talairach space. J Comput Assist Tomogr 1994;18:192-205.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 192-205
    • Collins, L.1    Neelin, P.2    Terrence, P.3    Evans, A.4
  • 4
    • 0023722018 scopus 로고
    • Enhanced detection of focal brain responses using intersubject averaging and change-distribution analysis of subtracted PET images
    • Fox PT, Raichle ME. Enhanced detection of focal brain responses using intersubject averaging and change-distribution analysis of subtracted PET images. J Cereb Blood Flow Metab 1988;8:642-53.
    • (1988) J Cereb Blood Flow Metab , vol.8 , pp. 642-653
    • Fox, P.T.1    Raichle, M.E.2
  • 5
    • 84947594360 scopus 로고    scopus 로고
    • This-plate splines and the atlas problem for biomedical images
    • Colchester ACF, Hawkes D, eds. Berlin: Springer-Verlag
    • Bookstein FL. This-plate splines and the atlas problem for biomedical images. In: Colchester ACF, Hawkes D, eds. Information processing in medical imaging. Berlin: Springer-Verlag, 1991: 327-42. (Lecture notes in computer science; vol 511).
    • (1991) Information Processing in Medical Imaging , pp. 327-342
    • Bookstein, F.L.1
  • 6
    • 84947594360 scopus 로고    scopus 로고
    • Bookstein FL. This-plate splines and the atlas problem for biomedical images. In: Colchester ACF, Hawkes D, eds. Information processing in medical imaging. Berlin: Springer-Verlag, 1991: 327-42. (Lecture notes in computer science; vol 511).
    • Lecture Notes in Computer Science , vol.511
  • 7
    • 0029186447 scopus 로고
    • A modality-independent approach to spatial normalization of tomographic images of the human brain
    • Lancaster JL, Glass TG, Lankipalli BR, Downs H, Mayberg H, Fox PT. A modality-independent approach to spatial normalization of tomographic images of the human brain. Hum Brain Map 1995; 3:209-23.
    • (1995) Hum Brain Map , vol.3 , pp. 209-223
    • Lancaster, J.L.1    Glass, T.G.2    Lankipalli, B.R.3    Downs, H.4    Mayberg, H.5    Fox, P.T.6
  • 9
    • 0026017296 scopus 로고
    • A computerized brain atlas: Construction, anatomical content and some applications
    • Greitz T, Bohm C, Holte S, Eriksson L. A computerized brain atlas: construction, anatomical content and some applications. J Comput Assist Tomogr 1991;15:26-38.
    • (1991) J Comput Assist Tomogr , vol.15 , pp. 26-38
    • Greitz, T.1    Bohm, C.2    Holte, S.3    Eriksson, L.4
  • 10
    • 0027531938 scopus 로고
    • Elastically deforming 3D atlas to match anatomical brain images
    • Gee J, Reivich M, Bajscy R. Elastically deforming 3D atlas to match anatomical brain images. J Comput Assist Tomogr 1993;17: 225-36.
    • (1993) J Comput Assist Tomogr , vol.17 , pp. 225-236
    • Gee, J.1    Reivich, M.2    Bajscy, R.3
  • 11
    • 0028591361 scopus 로고
    • Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines
    • IEEE Computer Society, Seattle, June
    • Szeliski R, Lavalle S. Matching 3-D anatomical surfaces with non-rigid deformations using octree-splines. IEEE Workshop on Biomedical Image Analysis, IEEE Computer Society, Seattle, June 1994.
    • (1994) IEEE Workshop on Biomedical Image Analysis
    • Szeliski, R.1    Lavalle, S.2
  • 13
    • 84956858831 scopus 로고    scopus 로고
    • Declerck J, Subsol G, Thirion JP, Ayache N. Automatic retrieval of anatomical structures in 3D medical images. In: Ayache N, ed. Information processing, virtual reality and robotics in medicine. Berlin: Springer-Verlag, 1995:153-62. (Lecture notes in computer science; vol 905).
    • Lecture Notes in Computer Science , vol.905
  • 15
    • 0027940111 scopus 로고
    • Anatomic standardization: Linear scaling and nonlinear warping of functional brain images
    • Minoshima S, Koeppe RA, Frey KA, Kuhl DE. Anatomic standardization: linear scaling and nonlinear warping of functional brain images. J Nucl Med 1994;35:1528-37.
    • (1994) J Nucl Med , vol.35 , pp. 1528-1537
    • Minoshima, S.1    Koeppe, R.A.2    Frey, K.A.3    Kuhl, D.E.4
  • 17
  • 20
    • 0029311180 scopus 로고
    • CBA - An atlas based software tool used to facilitate the interpretation of neuroimaging data
    • Thurfjell L, Bohm C, Bengtsson E. CBA - an atlas based software tool used to facilitate the interpretation of neuroimaging data. Comput Methods Prog Biomed 1995;4:51-71.
    • (1995) Comput Methods Prog Biomed , vol.4 , pp. 51-71
    • Thurfjell, L.1    Bohm, C.2    Bengtsson, E.3
  • 21
    • 0020761029 scopus 로고
    • Adjust-able computerized stereotaxic brain atlas for transmission and emission tomography
    • Bohm C, Greitz T, Kingsley D, Berggren BM, Olsson L. Adjust-able computerized stereotaxic brain atlas for transmission and emission tomography. AJNR 1983;4:731-3.
    • (1983) AJNR , vol.4 , pp. 731-733
    • Bohm, C.1    Greitz, T.2    Kingsley, D.3    Berggren, B.M.4    Olsson, L.5
  • 22
    • 0028938469 scopus 로고
    • A rapid and accurate method to realign PET scans utilizing image edge information
    • Andersson JLR. A rapid and accurate method to realign PET scans utilizing image edge information. J Nucl Med 1995;36:657-69.
    • (1995) J Nucl Med , vol.36 , pp. 657-669
    • Andersson, J.L.R.1
  • 23
    • 0001008029 scopus 로고
    • An efficient method for finding the minimum of a function of several variables without calculating derivatives
    • Powell MJD. An efficient method for finding the minimum of a function of several variables without calculating derivatives. Comput J 1964;7:155-63.
    • (1964) Comput J , vol.7 , pp. 155-163
    • Powell, M.J.D.1
  • 25
    • 0025291291 scopus 로고
    • Accuracy and precision of the computerized brain atlas program for localization and quantification in positron emission tomography
    • Seitz RJ, Bohm C, Greitz T, et al. Accuracy and precision of the computerized brain atlas program for localization and quantification in positron emission tomography. J Cereb Blood Flow Metab 1990;10:443-57.
    • (1990) J Cereb Blood Flow Metab , vol.10 , pp. 443-457
    • Seitz, R.J.1    Bohm, C.2    Greitz, T.3
  • 26
    • 0027130953 scopus 로고
    • Human brain atlas: For high resolution functional and anatomical mapping
    • Roland PE, Graufelds CJ, Wählin J, et al. Human brain atlas: for high resolution functional and anatomical mapping. Hum Brain Map 1994;1:173-84.
    • (1994) Hum Brain Map , vol.1 , pp. 173-184
    • Roland, P.E.1    Graufelds, C.J.2    Wählin, J.3
  • 32
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformations of the projections
    • Bergström M, Eriksson L, Bohm C, Blomqvist G, Litton J. Correction for scattered radiation in a ring detector positron camera by integral transformations of the projections. J Comput Assist Tomogr 1983;7:42-50.
    • (1983) J Comput Assist Tomogr , vol.7 , pp. 42-50
    • Bergström, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 33
    • 0028006399 scopus 로고
    • The ECAT Exact HR: Performance of a new high resolution positron scanner
    • Wienhard K, Dahlbom M, Eriksson L, et al. The ECAT Exact HR: performance of a new high resolution positron scanner. J Comput Assist Tomogr 1994;18:110-8.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 110-118
    • Wienhard, K.1    Dahlbom, M.2    Eriksson, L.3
  • 34
    • 0008200306 scopus 로고
    • A European activation study of verbal fluency: Results from a multi centre PET experiment. EU concerted action on functional imaging (Essen, Groeningen, Leuven, Liege, London, Lyon, Milano, Orsay, Stockholm)
    • Frackowiak RSJ. A European activation study of verbal fluency: results from a multi centre PET experiment. EU concerted action on functional imaging (Essen, Groeningen, Leuven, Liege, London, Lyon, Milano, Orsay, Stockholm). J Cereb Blood Flow Metab 1995;S1:52.
    • (1995) J Cereb Blood Flow Metab , vol.S1 , pp. 52
    • Frackowiak, R.S.J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.