메뉴 건너뛰기




Volumn 48, Issue 1, 1997, Pages 133-134

Measurements with Chinese LiF:Mg,Cu,P (GR 200) TL detectors using a volume-type oven

Author keywords

[No Author keywords available]

Indexed keywords

ANNEALING; OVENS; RADIATION DETECTORS; RADIATION PROTECTION; RADIOACTIVITY MEASUREMENT; READOUT SYSTEMS; THERMOLUMINESCENCE;

EID: 0031024973     PISSN: 09698043     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-8043(96)00175-3     Document Type: Article
Times cited : (3)

References (10)
  • 1
    • 0011290280 scopus 로고
    • Solid Dosimetric Detector and Method Laboratory, P.O. Box 1033, Ext. 204, Beijing, P.R. China
    • Cai G. G. (1987) Material description. Solid Dosimetric Detector and Method Laboratory, P.O. Box 1033, Ext. 204, Beijing, P.R. China.
    • (1987) Material Description
    • Cai, G.G.1
  • 2
    • 0000813512 scopus 로고    scopus 로고
    • PC assisted dose assessment in clinical TL dosimetry and QA
    • Fill U. A., Regulla D. and Sprunck M. (1996) PC assisted dose assessment in clinical TL dosimetry and QA. Radiat. Prof. Dosim. 66, 249-253.
    • (1996) Radiat. Prof. Dosim. , vol.66 , pp. 249-253
    • Fill, U.A.1    Regulla, D.2    Sprunck, M.3
  • 4
    • 0004026243 scopus 로고
    • The GSF secondary standard dosimetry laboratory for photon and beta radiation
    • Nahrstedt U. (1995) The GSF secondary standard dosimetry laboratory for photon and beta radiation. GSF-Bericht 9/95
    • (1995) GSF-Bericht 9/95
    • Nahrstedt, U.1
  • 5
    • 0029842048 scopus 로고
    • Further studies of the stability of LiF:Mg,Cu,P (GR-200) at maximum readout temperatures between 240°C and 280°C
    • Oster L., Horowitz Y. S. and Horowitz A. (1995) Further studies of the stability of LiF:Mg,Cu,P (GR-200) at maximum readout temperatures between 240°C and 280°C. Radiat. Prot. Dosim. 65, 159-162.
    • (1995) Radiat. Prot. Dosim. , vol.65 , pp. 159-162
    • Oster, L.1    Horowitz, Y.S.2    Horowitz, A.3
  • 6
  • 10
    • 0022586754 scopus 로고
    • Newly developed highly sensitive LiF (Mg,Cu,P) TL chips with high signal-to-noise ratio
    • Wang Soushan, Chen Guolong, Wu Fang, Li Yuanfang, Zha Ziying and Zhu Jianhuan (1986) Newly developed highly sensitive LiF (Mg,Cu,P) TL chips with high signal-to-noise ratio. Radiat. Prot. Dosim. 14, 223-227.
    • (1986) Radiat. Prot. Dosim. , vol.14 , pp. 223-227
    • Soushan, W.1    Guolong, C.2    Fang, W.3    Yuanfang, L.4    Ziying, Z.5    Jianhuan, Z.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.