메뉴 건너뛰기




Volumn 37, Issue 3, 1997, Pages 410-417

Rapid cardiac imaging with turbo BRISK

Author keywords

cardiac imaging; fast imaging; k space manipulation

Indexed keywords

CARDIAC IMAGING; CARDIAC PATIENTS; FAST IMAGING; INTERPOLATION SCHEMES; K SPACE; PROCESSING STRATEGIES; SPARSE SAMPLING; UNIFORM SAMPLING;

EID: 0031019523     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910370319     Document Type: Article
Times cited : (20)

References (14)
  • 4
    • 0028869435 scopus 로고
    • Block regional interpolation scheme for k-space (BRISK): A rapid cardiac imaging technique
    • M. Doyle, E. G. Walsh, G. G. Blackwell, G. M. Pohost, Block regional interpolation scheme for k-space (BRISK): a rapid cardiac imaging technique. Magn. Reson. Med. 33, 163-170 (1995).
    • (1995) Magn. Reson. Med. , vol.33 , pp. 163-170
    • Doyle, M.1    Walsh, E.G.2    Blackwell, G.G.3    Pohost, G.M.4
  • 5
    • 0028936695 scopus 로고
    • Continuous update with random encoding (CURE): A new strategy for dynamic imaging
    • T. Parrish, X. Hu, Continuous update with random encoding (CURE): a new strategy for dynamic imaging. Magn. Reson. Med. 33, 326-336 (1995).
    • (1995) Magn. Reson. Med. , vol.33 , pp. 326-336
    • Parrish, T.1    Hu, X.2
  • 6
    • 0029088782 scopus 로고
    • Magnetic resonance fluoroscopy using spirals with variable sampling densities
    • D. M. Spielman, J. M. Pauly, G. H. Meyer, Magnetic resonance fluoroscopy using spirals with variable sampling densities. Magn. Reson. Med. 34, 388-394 (1995).
    • (1995) Magn. Reson. Med. , vol.34 , pp. 388-394
    • Spielman, D.M.1    Pauly, J.M.2    Meyer, G.H.3
  • 8
    • 0025961482 scopus 로고
    • Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence
    • D. J. Atkinson and R. R. Edelman, Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence. Radiology 178, 357-360 (1991).
    • (1991) Radiology , vol.178 , pp. 357-360
    • Atkinson, D.J.1    Edelman, R.R.2
  • 11
    • 0027070940 scopus 로고
    • Cardiac tagging with breath-hold cine MRI
    • E. R. McVeigh, E. Atalar, Cardiac tagging with breath-hold cine MRI. Magn. Reson. Med. 28, 318-327 (1992).
    • (1992) Magn. Reson. Med. , vol.28 , pp. 318-327
    • McVeigh, E.R.1    Atalar, E.2
  • 12
    • 0028953895 scopus 로고
    • Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques
    • T. K. F. Foo, M. A. Bernstein, A. M. Aisen, R. J. Hernandez, B. D. Collick, T. Burnstein, Improved ejection fraction and flow velocity estimates with use of view sharing and uniform repetition time excitation with fast cardiac techniques. Radiology 195, 471-478 (1995).
    • (1995) Radiology , vol.195 , pp. 471-478
    • Foo, T.K.F.1    Bernstein, M.A.2    Aisen, A.M.3    Hernandez, R.J.4    Collick, B.D.5    Burnstein, T.6
  • 13
    • 0028157383 scopus 로고
    • Is 300 msec too long for cardiac MR imaging? Feasibility study demonstrating changes in left ventricular cross-sectional area with use off single-shot TurboFLASH imaging
    • T. Matsuda, H. Yamada, M. Kida, S. Sasayama, Is 300 msec too long for cardiac MR imaging? Feasibility study demonstrating changes in left ventricular cross-sectional area with use off single-shot TurboFLASH imaging. Radiology 190, 353-362 (1994).
    • (1994) Radiology , vol.190 , pp. 353-362
    • Matsuda, T.1    Yamada, H.2    Kida, M.3    Sasayama, S.4
  • 14
    • 0027216325 scopus 로고
    • Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI
    • G. McGibney, M. R. Smith, S. T. Nichols, A. Crawley, Quantitative evaluation of several partial Fourier reconstruction algorithms used in MRI. Magn. Reson. Med. 30, 51-59 (1993).
    • (1993) Magn. Reson. Med. , vol.30 , pp. 51-59
    • McGibney, G.1    Smith, M.R.2    Nichols, S.T.3    Crawley, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.