메뉴 건너뛰기




Volumn 33, Issue 1, 1997, Pages 156-163

Where to place the Doppler sample volume in the human main pulmonary artery: Evaluated from magnetic resonance phase velocity maps

Author keywords

blood velocity profile; Doppler velocity recording; human; NMR; pulmonary artery

Indexed keywords

ADULT; ARTICLE; BLOOD FLOW VELOCITY; CONTROLLED STUDY; DOPPLER FLOWMETRY; FEMALE; HEART FUNCTION; HEART OUTPUT; HUMAN; MALE; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PULMONARY ARTERY;

EID: 0031015136     PISSN: 00086363     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0008-6363(96)00175-7     Document Type: Article
Times cited : (5)

References (33)
  • 1
    • 0025900582 scopus 로고
    • Alternatives to Swan-Ganz cardiac output monitoring
    • Moore FA, Haenel JB, Moore EE. Alternatives to Swan-Ganz cardiac output monitoring. Surg Clin North Am. 71:1991;699-721.
    • (1991) Surg Clin North Am , vol.71 , pp. 699-721
    • Moore, F.A.1    Haenel, J.B.2    Moore, E.E.3
  • 2
    • 0023919731 scopus 로고
    • Is the measurement of cardiac output useful in clinical practice?
    • Taylor SH, Silke B. Is the measurement of cardiac output useful in clinical practice? Br J Anaesth. 60:1988;90S-98S.
    • (1988) Br J Anaesth , vol.60
    • Taylor, S.H.1    Silke, B.2
  • 4
    • 0024992702 scopus 로고
    • Usefulness of left and right oblique subcostal view in the echo-Doppler investigation of pulmonary arterial blood flow in patients with chronic obstructive pulmonary disease. The subxiphoid view in the echo-Doppler evaluation of pulmonary blood flow
    • Ferrazza A, Marino B, Giusti V, Affinito V, Ragonese P. Usefulness of left and right oblique subcostal view in the echo-Doppler investigation of pulmonary arterial blood flow in patients with chronic obstructive pulmonary disease. The subxiphoid view in the echo-Doppler evaluation of pulmonary blood flow. Chest. 98:1990;286-289.
    • (1990) Chest , vol.98 , pp. 286-289
    • Ferrazza, A.1    Marino, B.2    Giusti, V.3    Affinito, V.4    Ragonese, P.5
  • 5
    • 0025804317 scopus 로고
    • Intraoperative estimation of cardiac output by transesophageal pulsed Doppler echocardiography
    • Muhiudeen IA, Kuecherer HF, Lee E, Cahalan MK, Schiller NB. Intraoperative estimation of cardiac output by transesophageal pulsed Doppler echocardiography. Anesthesiology. 74:1991;9-14.
    • (1991) Anesthesiology , vol.74 , pp. 9-14
    • Muhiudeen, I.A.1    Kuecherer, H.F.2    Lee, E.3    Cahalan, M.K.4    Schiller, N.B.5
  • 6
    • 0023434489 scopus 로고
    • Continuous measurement of intracardiac and pulmonary blood flow velocities with transesophageal pulsed Doppler echocardiography: Technique and initial clinical experience
    • Roewer N, Bednarz F, Schulte am Esch J. Continuous measurement of intracardiac and pulmonary blood flow velocities with transesophageal pulsed Doppler echocardiography: technique and initial clinical experience. J Cardiothorac Anesth. 1:1987;418-428.
    • (1987) J Cardiothorac Anesth , vol.1 , pp. 418-428
    • Roewer, N.1    Bednarz, F.2    Schulte Am Esch, J.3
  • 7
    • 0025983726 scopus 로고
    • Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography
    • Savino JS, Troianos CA, Aukburg S, Weiss R, Reichek N. Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography. Anesthesiology. 75:1991;445-451.
    • (1991) Anesthesiology , vol.75 , pp. 445-451
    • Savino, J.S.1    Troianos, C.A.2    Aukburg, S.3    Weiss, R.4    Reichek, N.5
  • 8
    • 0025221561 scopus 로고
    • Instantaneous and continuous cardiac output in humans obtained with a Doppler pulmonary artery catheter
    • Segal J, Nassi M, Ford AJ Jr, Schuenemeyer TD. Instantaneous and continuous cardiac output in humans obtained with a Doppler pulmonary artery catheter. J Am Coll Cardiol. 16:1990;1398-1407.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 1398-1407
    • Segal, J.1    Nassi, M.2    Ford A.J., Jr.3    Schuenemeyer, T.D.4
  • 9
    • 0025914221 scopus 로고
    • Continuous determination of cardiac output using a flow-directed Doppler pulmonary artery catheter [see comments]
    • Sega J, Gaudiani V, Nishimura T. Continuous determination of cardiac output using a flow-directed Doppler pulmonary artery catheter [see comments]. J Cardiothorac Vasc Anesth. 5:1991;309-315.
    • (1991) J Cardiothorac Vasc Anesth , vol.5 , pp. 309-315
    • Sega, J.1    Gaudiani, V.2    Nishimura, T.3
  • 10
    • 0024566740 scopus 로고
    • Instantaneous and continuous cardiac output obtained with a Doppler pulmonary artery catheter
    • Segal J, Pearl RG, Ford AJJ, Stern RA, Gehlbach SM. Instantaneous and continuous cardiac output obtained with a Doppler pulmonary artery catheter. J Am Coll Cardiol. 13:1989;1382-1392.
    • (1989) J Am Coll Cardiol , vol.13 , pp. 1382-1392
    • Segal, J.1    Pearl, R.G.2    Ford, A.J.J.3    Stern, R.A.4    Gehlbach, S.M.5
  • 11
    • 85047678568 scopus 로고
    • Three dimensional visualisation of velocity profiles in the normal porcine pulmonary trunk
    • Somod L, Hasenkam JM, Kim WY, Nygaard H, Paulsen PK. Three dimensional visualisation of velocity profiles in the normal porcine pulmonary trunk. Cardiovasc Res. 27:1993;291-295.
    • (1993) Cardiovasc Res , vol.27 , pp. 291-295
    • Somod, L.1    Hasenkam, J.M.2    Kim, W.Y.3    Nygaard, H.4    Paulsen, P.K.5
  • 12
    • 0028025114 scopus 로고
    • Two-dimensional mitral velocity profiles in pig models using epicardial Doppler echocardiography
    • Kim WY, Bisgaard T, Nielsen SL, et al. Two-dimensional mitral velocity profiles in pig models using epicardial Doppler echocardiography. J Am Coll Cardiol. 24:1994;532-545.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 532-545
    • Kim, W.Y.1    Bisgaard, T.2    Nielsen, S.L.3
  • 14
    • 0014897466 scopus 로고
    • Velocity profiles in the main pulmonary artery of dogs and man, measured with a thin-film resistance anemometer
    • Reuben SR, Swadling JP, Lee GdeJ. Velocity profiles in the main pulmonary artery of dogs and man, measured with a thin-film resistance anemometer. Circ Res. 27:1970;995-1001.
    • (1970) Circ Res , vol.27 , pp. 995-1001
    • Reuben, S.R.1    Swadling, J.P.2    Lee, Gde.J.3
  • 16
    • 0024374262 scopus 로고
    • Pulmonary artery distensibility and blood flow patterns: A magnetic resonance study of normal subjects and of patients with pulmonary arterial hypertension
    • Bogren HG, Klipstein RH, Mohiaddin RH, et al. Pulmonary artery distensibility and blood flow patterns: a magnetic resonance study of normal subjects and of patients with pulmonary arterial hypertension. Am Heart J. 118:1989;990-999.
    • (1989) Am Heart J , vol.118 , pp. 990-999
    • Bogren, H.G.1    Klipstein, R.H.2    Mohiaddin, R.H.3
  • 17
    • 0026691067 scopus 로고
    • Pulmonary hypertension: Pulmonary flow quantification and flow profile analysis with velocity-encoded cine MR imaging
    • Kondo C, Caputo GR, Masui T, et al. Pulmonary hypertension: pulmonary flow quantification and flow profile analysis with velocity-encoded cine MR imaging. Radiology. 183:1992;751-758.
    • (1992) Radiology , vol.183 , pp. 751-758
    • Kondo, C.1    Caputo, G.R.2    Masui, T.3
  • 18
    • 0027745642 scopus 로고
    • Magnetic resonance assessment of the pulmonary arterial trunk anatomy, flow, pulsatility and distensibility
    • Paz R, Mohiaddin RH, Longmore DB. Magnetic resonance assessment of the pulmonary arterial trunk anatomy, flow, pulsatility and distensibility. Eur Heart J. 14:1993;1524-1530.
    • (1993) Eur Heart J , vol.14 , pp. 1524-1530
    • Paz, R.1    Mohiaddin, R.H.2    Longmore, D.B.3
  • 19
    • 0027948393 scopus 로고
    • Three-dimensional visualization of the velocity profiles in the human main pulmonary artery using magnetic resonance phase velocity mapping
    • Sloth E, Houlind KC, Oyre S, Kim WY, Pedersen EM, Jørgensen HS, Hasenkam JM. Three-dimensional visualization of the velocity profiles in the human main pulmonary artery using magnetic resonance phase velocity mapping. Am Heart J. 128:1994;1130-1138.
    • (1994) Am Heart J , vol.128 , pp. 1130-1138
    • Sloth, E.1    Houlind, K.C.2    Oyre, S.3    Kim, W.Y.4    Pedersen, E.M.5    Jørgensen, H.S.6    Hasenkam, J.M.7
  • 21
    • 0027602212 scopus 로고
    • Semiautomated method for noise reduction and background phase error correction on MR phase velocity data
    • Walker PG, Cranney GB, Scheidegger MB, Waseleski G, Pohost GM, Yoganathan AP. Semiautomated method for noise reduction and background phase error correction on MR phase velocity data. JMRI. 3:1993;521-530.
    • (1993) JMRI , vol.3 , pp. 521-530
    • Walker, P.G.1    Cranney, G.B.2    Scheidegger, M.B.3    Waseleski, G.4    Pohost, G.M.5    Yoganathan, A.P.6
  • 22
    • 0028218466 scopus 로고
    • Visualization of flow by vector analysis of multidirectional cine MR velocity mapping
    • Mohiaddin RH, Yang GZ, Kilner PJ. Visualization of flow by vector analysis of multidirectional cine MR velocity mapping. J Comput Assist Tomogr. 18:1994;383-392.
    • (1994) J Comput Assist Tomogr , vol.18 , pp. 383-392
    • Mohiaddin, R.H.1    Yang, G.Z.2    Kilner, P.J.3
  • 23
    • 0028394387 scopus 로고
    • Multiplane transesophageal Doppler-echocardiographic measurements of the velocity profile in the human pulmonary artery
    • Sloth E, Pedersen EM, Nygaard H, Hasenkam JM, Juhl B. Multiplane transesophageal Doppler-echocardiographic measurements of the velocity profile in the human pulmonary artery. J Am Soc Echocardiogr. 7:1994;132-140.
    • (1994) J Am Soc Echocardiogr , vol.7 , pp. 132-140
    • Sloth, E.1    Pedersen, E.M.2    Nygaard, H.3    Hasenkam, J.M.4    Juhl, B.5
  • 24
    • 0021351565 scopus 로고
    • Analysis of blood flow in pulmonary hypertension with the pulsed Doppler flowmeter combined with cross sectional echocardiography
    • Okamoto M, Miyatake K, Kinoshita N, Sakakibara H, Nimura Y. Analysis of blood flow in pulmonary hypertension with the pulsed Doppler flowmeter combined with cross sectional echocardiography. Br Heart J. 51:1984;407-415.
    • (1984) Br Heart J , vol.51 , pp. 407-415
    • Okamoto, M.1    Miyatake, K.2    Kinoshita, N.3    Sakakibara, H.4    Nimura, Y.5
  • 25
    • 0022578337 scopus 로고
    • Characteristics of blood flow velocity in the hypertensive canine pulmonary artery
    • Frantz EG, Henry GW, Lucas CL, et al. Characteristics of blood flow velocity in the hypertensive canine pulmonary artery. Ultrasound Med Biol. 12:1986;379-385.
    • (1986) Ultrasound Med Biol , vol.12 , pp. 379-385
    • Frantz, E.G.1    Henry, G.W.2    Lucas, C.L.3
  • 26
    • 0026560844 scopus 로고
    • Three-dimensional visualization of pulmonary blood flow velocity profiles in lambs
    • Katayama H, Henry GW, Lucas CL, et al. Three-dimensional visualization of pulmonary blood flow velocity profiles in lambs. Jpn Heart J. 33:1992;95-111.
    • (1992) Jpn Heart J , vol.33 , pp. 95-111
    • Katayama, H.1    Henry, G.W.2    Lucas, C.L.3
  • 27
    • 0024208457 scopus 로고
    • Pulmonary blood velocity profile variability in open-chest dogs: Influence of acutely altered hemodynamic states on profiles, and influence of profiles on the accuracy of techniques for cardiac output determination
    • Lucas CL, Henry GW, Ferreiro JI, Ha B, Keagy BA, Wilcox BR. Pulmonary blood velocity profile variability in open-chest dogs: influence of acutely altered hemodynamic states on profiles, and influence of profiles on the accuracy of techniques for cardiac output determination. Heart Vessels. 4:1988;65-78.
    • (1988) Heart Vessels , vol.4 , pp. 65-78
    • Lucas, C.L.1    Henry, G.W.2    Ferreiro, J.I.3    Ha, B.4    Keagy, B.A.5    Wilcox, B.R.6
  • 28
    • 0027551982 scopus 로고
    • The effects of curvature on fluid flow fields in pulmonary artery models: Flow visualization studies
    • Lynch PG, Saylor A, Ha B, et al. The effects of curvature on fluid flow fields in pulmonary artery models: flow visualization studies. J Biomech Eng. 115:1993;97-103.
    • (1993) J Biomech Eng , vol.115 , pp. 97-103
    • Lynch, P.G.1    Saylor, A.2    Ha, B.3
  • 30
    • 0024551349 scopus 로고
    • Human abdominal aorta: Comparative measurements of blood flow with MR imaging and multigated Doppler US
    • Maier SE, Meier D, Boesiger P, Moser UT, Vieli A. Human abdominal aorta: comparative measurements of blood flow with MR imaging and multigated Doppler US. Radiology. 171:1989;487-492.
    • (1989) Radiology , vol.171 , pp. 487-492
    • Maier, S.E.1    Meier, D.2    Boesiger, P.3    Moser, U.T.4    Vieli, A.5
  • 32
    • 0000004140 scopus 로고
    • Measurement in medicine: The analysis of method comparison studies
    • Altman DG, Bland JM. Measurement in medicine: the analysis of method comparison studies. Statist. 32:1983;307-317.
    • (1983) Statist , vol.32 , pp. 307-317
    • Altman, D.G.1    Bland, J.M.2
  • 33
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1:1986;307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.