메뉴 건너뛰기




Volumn 37, Issue 2, 1997, Pages 285-291

Improved 2D time-of-flight angiography using a radial-line k-space acquisition

Author keywords

flow imaging; magnetic resonance imaging; radial lines; time of flight angiography

Indexed keywords

ANGIOGRAPHY; MAGNETIC RESONANCE IMAGING;

EID: 0031013495     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.1910370224     Document Type: Article
Times cited : (16)

References (21)
  • 1
    • 0024325998 scopus 로고
    • MR angiography with two-dimensional acquisition and three-dimensional display: Work in progress
    • P. J.Keller, B. P. Drayer, E. K. Fram, K. D. Williams, C. L. Dumoulin, S. P. Souza, MR angiography with two-dimensional acquisition and three-dimensional display: work in progress. Radiology 173, 527-532 (1989).
    • (1989) Radiology , vol.173 , pp. 527-532
    • Keller, P.J.1    Drayer, B.P.2    Fram, E.K.3    Williams, K.D.4    Dumoulin, C.L.5    Souza, S.P.6
  • 2
  • 4
    • 0027633134 scopus 로고
    • Pulsatile flow artifacts in two-dimensional time-of-flight MR angiography: Initial studies in elastic models of human carotid arteries
    • R. B. Buxton, C. W. Kerber, L. R. Frank, Pulsatile flow artifacts in two-dimensional time-of-flight MR angiography: initial studies in elastic models of human carotid arteries. J. Magn. Reson. Imaging 3, 625-636 (1993).
    • (1993) J. Magn. Reson. Imaging , vol.3 , pp. 625-636
    • Buxton, R.B.1    Kerber, C.W.2    Frank, L.R.3
  • 5
    • 0026885407 scopus 로고
    • Mechanisms of flow-induced signal loss in MR angiography
    • S. N. Urchuk, D. B. Plewes, Mechanisms of flow-induced signal loss in MR angiography. J. Magn. Reson. Imaging 2, 453-462 (1992).
    • (1992) J. Magn. Reson. Imaging , vol.2 , pp. 453-462
    • Urchuk, S.N.1    Plewes, D.B.2
  • 7
  • 9
    • 0028904705 scopus 로고
    • A velocity k-space analysis of flow effects in echo-planar and spiral imaging
    • D. G. Nishimura, P. Irarrazabal, C. H. Meyer, A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn. Reson. Med. 33, 549-556 (1995).
    • (1995) Magn. Reson. Med. , vol.33 , pp. 549-556
    • Nishimura, D.G.1    Irarrazabal, P.2    Meyer, C.H.3
  • 10
    • 0026696668 scopus 로고
    • Twisting radial lines with application to robust magnetic resonance imaging of irregular flow
    • J. I. Jackson, D. G. Nishimura, A. Macovski, Twisting radial lines with application to robust magnetic resonance imaging of irregular flow. Magn. Reson. Med. 25, 128-139 (1992).
    • (1992) Magn. Reson. Med. , vol.25 , pp. 128-139
    • Jackson, J.I.1    Nishimura, D.G.2    Macovski, A.3
  • 11
    • 0026344889 scopus 로고
    • On the nature and reduction of the displacement artifact in flow images
    • D. G. Nishimura, J. I. Jackson, J. M. Pauly, On the nature and reduction of the displacement artifact in flow images. Magn. Reson. Med. 22, 481-492 (1991).
    • (1991) Magn. Reson. Med. , vol.22 , pp. 481-492
    • Nishimura, D.G.1    Jackson, J.I.2    Pauly, J.M.3
  • 12
    • 0023735112 scopus 로고
    • Magnetic resonance angiography by selective inversion recovery using a compact gradient echo sequence
    • D. G. Nishimura, A. Macovski, J. I. Jackson, R. S. Hu, C. A. Stevick, L. Axel, magnetic resonance angiography by selective inversion recovery using a compact gradient echo sequence. Magn. Reson. Med. 8, 96-103 (1988).
    • (1988) Magn. Reson. Med. , vol.8 , pp. 96-103
    • Nishimura, D.G.1    Macovski, A.2    Jackson, J.I.3    Hu, R.S.4    Stevick, C.A.5    Axel, L.6
  • 13
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for Fourier inversion in computed tomography
    • J. D. O'Sullivan, A fast sinc function gridding algorithm for Fourier inversion in computed tomography. IEEE Trans. Med. Imaging 4, 200-207 (1985).
    • (1985) IEEE Trans. Med. Imaging , vol.4 , pp. 200-207
    • O'Sullivan, J.D.1
  • 16
    • 0027193344 scopus 로고
    • Atherosclerotic occlusive disease of the lower extremity: Prospective evaluation with two-dimensional time-of- flight MR angiography
    • E. K. Yucel, J. A. Kaufman, S. C. Geller, and A. C. Waltman, Atherosclerotic occlusive disease of the lower extremity: prospective evaluation with two-dimensional time-of- flight MR angiography. Radiology 187, 637-641 (1993).
    • (1993) Radiology , vol.187 , pp. 637-641
    • Yucel, E.K.1    Kaufman, J.A.2    Geller, S.C.3    Waltman, A.C.4
  • 17
    • 0026584054 scopus 로고
    • Popliteal and tibioperoneal arteries: Feasibility of two-dimensional time-of-flight MR angiography and phase velocity mapping
    • G. R. Caputo, T. Masui, G. A. W. Gooding, J. Chang, C. B. Higgins, Popliteal and tibioperoneal arteries: feasibility of two-dimensional time-of-flight MR angiography and phase velocity mapping. Radiology 182, 387-392 (1992).
    • (1992) Radiology , vol.182 , pp. 387-392
    • Caputo, G.R.1    Masui, T.2    Gooding, G.A.W.3    Chang, J.4    Higgins, C.B.5
  • 21
    • 0026399654 scopus 로고
    • A homogeneity correction method for magnetic resonance imaging with time-varying gradients
    • D. C. Noll, C. H. Meyer, J. M. Pauly, D. G. Nishimura, A. Macovski, A homogeneity correction method for magnetic resonance imaging with time-varying gradients. IEEE Trans. Med. Imaging 10, 629-637 (1991).
    • (1991) IEEE Trans. Med. Imaging , vol.10 , pp. 629-637
    • Noll, D.C.1    Meyer, C.H.2    Pauly, J.M.3    Nishimura, D.G.4    Macovski, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.