메뉴 건너뛰기




Volumn 44, Issue 1, 1997, Pages 77-89

Development of a microcontroller-based automatic control system for the electrohydraulic total artificial heart

Author keywords

Artificial biological organs; biological control systems; blood pumps; implantable biomedical devices; microprocessor applications

Indexed keywords

ANIMAL EXPERIMENT; ARTICLE; ARTIFICIAL HEART; ASSISTED CIRCULATION; BLOOD PUMP; CATTLE; DEVICE; HEART OUTPUT; IMPLANTATION; NONHUMAN; RELIABILITY;

EID: 0031012313     PISSN: 00189294     EISSN: None     Source Type: Journal    
DOI: 10.1109/10.553715     Document Type: Article
Times cited : (8)

References (23)
  • 1
    • 0027454375 scopus 로고
    • "An atrial hydraulic shunt in a total artificial heart-A balance mechanism for the bronchial shunt,"
    • R. T. V. Rung, L. S. Yu, B. Ochs, S. Parnis, and O. H. Frazier, "An atrial hydraulic shunt in a total artificial heart-A balance mechanism for the bronchial shunt," Amer. Soc. Artif. Intern. Organs. J., vol. 39, pp. M213-M217, 1993.
    • (1993) Amer. Soc. Artif. Intern. Organs. J. , vol.39
    • Rung, R.T.V.1    Yu, L.S.2    Ochs, B.3    Parnis, S.4    Frazier, O.H.5
  • 5
    • 0025737879 scopus 로고
    • "Right-left ventricular output balance in the totally implantable artificial heart,"
    • D. B. Olsen, R. K. White, J. W. Long,.-and P. S. Khanwilkar, "Right-left ventricular output balance in the totally implantable artificial heart," Int. J. Artif. Organs, vol. 14, pp. 359-364, 1991.
    • (1991) Int. J. Artif. Organs , vol.14 , pp. 359-364
    • Olsen, D.B.1    White, R.K.2    Long, J.W.3    Khanwilkar, P.S.4
  • 6
    • 0006926154 scopus 로고
    • "Relative importance of venous and arterial resistances in controlling venous return and cardiac output,"
    • A. C. Guyton, J. B. Abemathy, J. B. Längsten, B. N. Kaufmann, and H. M. Fairchild, "Relative importance of venous and arterial resistances in controlling venous return and cardiac output," Amer. J. Physiol, vol. 196, pp. 1008-1012, 1959.
    • (1959) Amer. J. Physiol , vol.196 , pp. 1008-1012
    • Guyton, A.C.1    Abemathy, J.B.2    Längsten, J.B.3    Kaufmann, B.N.4    Fairchild, H.M.5
  • 7
    • 8544255049 scopus 로고    scopus 로고
    • "Blood pumps as a bridge to cardiac trans-plantation: Characteristics and development," in
    • R. De Paulis and D. B. Olsen, "Blood pumps as a bridge to cardiac trans-plantation: Characteristics and development," in Assisted Circulation 3, F. Unger, Ed. Berlin Heidelberg: Springer-Verlag, 1989, pp. 313-325.
    • Assisted Circulation , vol.3 , pp. 313-325
    • De Paulis, R.1    Olsen, D.B.2
  • 8
    • 0027134907 scopus 로고
    • "Adaptive full-ejection point detection for automatic control of the electrohydraulic total artificial heart,"
    • H. C. Kim, P. S. Khanwilkar, J. W. Long, and D. B. Olsen, "Adaptive full-ejection point detection for automatic control of the electrohydraulic total artificial heart," Amer. Soc. Artif. Intern. Organs. J., vol. 39, pp. 899-903, 1993.
    • (1993) Amer. Soc. Artif. Intern. Organs. J. , vol.39 , pp. 899-903
    • Kim, H.C.1    Khanwilkar, P.S.2    Long, J.W.3    Olsen, D.B.4
  • 11
    • 0025455926 scopus 로고
    • "In vitro analysis of an atrial shunt in balancing an electrohydraulic total artificial heart,"
    • P. S. Khanwilkar, L W. Long, J. W: Holfert, and D. B. Olsen
    • K. R. Crump, P. S. Khanwilkar, L W. Long, J. W: Holfert, and D. B. Olsen, "In vitro analysis of an atrial shunt in balancing an electrohydraulic total artificial heart," Trans. Amer. Soc. Artif. Intern. Organs, vol. 36, pp. M254-M257, 1990.
    • (1990) Trans. Amer. Soc. Artif. Intern. Organs , vol.36
    • Crump, K.R.1
  • 17
    • 0022197703 scopus 로고
    • "Development of hemoglobin oxygen optical sensors for automatic control- Of artificial- heart output,"
    • S. Takatani, T. Tanaka, and T. Nakatani, "Development of hemoglobin oxygen optical sensors for automatic control- of artificial- heart output," Trans. Amer. Soc. Artif. Intern. Organs, vol. 31, pp. 45-49, 1985.
    • (1985) Trans. Amer. Soc. Artif. Intern. Organs, Vol. , vol.31 , pp. 45-49
    • Takatani, S.1    Tanaka, T.2    Nakatani, T.3
  • 20
    • 0024704628 scopus 로고
    • "A unique left-right flow imbalance compensation scheme for an implantable total artificial heart,"
    • R. T. V. Kung, B. Ochs, and P. I. Singh, "A unique left-right flow imbalance compensation scheme for an implantable total artificial heart," Trans. Amer. Soc. Artif: Intern. Organs, vol. 35, pp. 468-470, 1989.
    • (1989) Trans. Amer. Soc. Artif: Intern. Organs , vol.35 , pp. 468-470
    • Kung, R.T.V.1    Ochs, B.2    Singh, P.I.3
  • 21
    • 0026732176 scopus 로고
    • "Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber,"
    • H. C. Kim and B. G. Min, "Cardiac output regulation in the moving actuator total artificial heart without a compliance chamber," Amer. Soc. Artif. Intern. Organs J., vol. 38, pp. 846-850, 1992.
    • (1992) Amer. Soc. Artif. Intern. Organs J. , vol.38 , pp. 846-850
    • Kim, H.C.1    Min, B.G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.