메뉴 건너뛰기




Volumn 23, Issue 4, 1997, Pages 591-596

Rapid measurement of the spatial resolution of colour flow scanners

Author keywords

Colour velocity; Doppler ultrasound; Spatial resolution

Indexed keywords

ATTENUATION; COLOR IMAGE PROCESSING; DOPPLER EFFECT; OPTICAL RESOLVING POWER;

EID: 0031009955     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(97)00035-5     Document Type: Article
Times cited : (5)

References (11)
  • 1
    • 0026157247 scopus 로고
    • Accuracy of colour Doppler ultrasound velocity measurements in small vessels
    • Forsberg F, Thomas N, Roberts VC. Accuracy of colour Doppler ultrasound velocity measurements in small vessels. J Biomed Eng 1991;13:249-254.
    • (1991) J Biomed Eng , vol.13 , pp. 249-254
    • Forsberg, F.1    Thomas, N.2    Roberts, V.C.3
  • 2
    • 0011205846 scopus 로고
    • Basic theory of the imaging process in the context of industrial radiology, part 2: Modulation transfer function, image noise, information theory
    • Moores BM, Parker RP, Pullan BR, eds. Chichester: John Wiley & Sons
    • Halmshaw R. Basic theory of the imaging process in the context of industrial radiology, part 2: Modulation transfer function, image noise, information theory. In: Moores BM, Parker RP, Pullan BR, eds. Physical aspects of medical imaging. Chichester: John Wiley & Sons, 1981:17-37.
    • (1981) Physical Aspects of Medical Imaging , pp. 17-37
    • Halmshaw, R.1
  • 3
    • 0021960233 scopus 로고
    • A set of x-ray test objects for quality control in television fluoroscopy
    • Hay GA, Clarke OF, Coleman NJ, Cowen AR. A set of x-ray test objects for quality control in television fluoroscopy. Brit J Radiol 1985;58:335-344.
    • (1985) Brit J Radiol , vol.58 , pp. 335-344
    • Hay, G.A.1    Clarke, O.F.2    Coleman, N.J.3    Cowen, A.R.4
  • 5
    • 0028080263 scopus 로고
    • Choice of moving target for a string phantom: I. Measurement of filament backscatter characteristics
    • Hoskins PR. Choice of moving target for a string phantom: I. Measurement of filament backscatter characteristics. Ultrasound Med Biol 1994a;20:773-780.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 773-780
    • Hoskins, P.R.1
  • 6
    • 0027944417 scopus 로고
    • Choice of moving target for a string phantom: II. On the testing of Doppler ultrasound systems
    • Hoskins PR. Choice of moving target for a string phantom: II. On the testing of Doppler ultrasound systems. Ultrasound Med Biol 1994b;20:781-789.
    • (1994) Ultrasound Med Biol , vol.20 , pp. 781-789
    • Hoskins, P.R.1
  • 7
    • 0024343930 scopus 로고
    • A computer controlled flow phantom for generation of physiological Doppler waveforms
    • Hoskins PR, Anderson T, McDicken WN. A computer controlled flow phantom for generation of physiological Doppler waveforms. Phys Med Biol 1989;34:1709-1717.
    • (1989) Phys Med Biol , vol.34 , pp. 1709-1717
    • Hoskins, P.R.1    Anderson, T.2    McDicken, W.N.3
  • 9
    • 0022597346 scopus 로고
    • A versatile test-object for the assessment of the performance of Doppler flow instruments
    • McDicken WN. A versatile test-object for the assessment of the performance of Doppler flow instruments. Ultrasound Med Biol 1986;12:245-249.
    • (1986) Ultrasound Med Biol , vol.12 , pp. 245-249
    • McDicken, W.N.1
  • 11
    • 0026734703 scopus 로고
    • A velocity evaluation phantom for colour flow and pulsed Doppler instruments
    • Rickey DW, Rankin R, Fenster A. A velocity evaluation phantom for colour flow and pulsed Doppler instruments. Ultrasound Med Biol 1992;18:479-494.
    • (1992) Ultrasound Med Biol , vol.18 , pp. 479-494
    • Rickey, D.W.1    Rankin, R.2    Fenster, A.3