Volumn 25, Issue 2, 1997, Pages 98-102

Radiation safety considerations for PET centers

Author keywords

Facility design; PET; Radiation monitoring; Radiation safety

Indexed keywords

RADIOISOTOPE;

EID: 0031008996     PISSN: 00914916     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (12)

References (16)
  • 1
    • 0029065732 scopus 로고
    • Personnel monitoring observations
    • Bloe F, Williams A. Personnel monitoring observations. J Nucl Med Technol 1995;23:82-86.
    • (1995) J Nucl Med Technol , vol.23 , pp. 82-86
    • Bloe, F.1    Williams, A.2
  • 2
    • 0004171860 scopus 로고
    • Washington, D.C.: Government Printing Office
    • U.S. Department of Health, Education and Welfare. Public Health Service. Radiological health handbook. Washington, D.C.: Government Printing Office; 1970.
    • (1970) Radiological Health Handbook
  • 3
    • 6544256239 scopus 로고
    • Radiation safety considerations in a positron tomography center
    • Browa TF, Yasillo NJ, Kronmal SL, et al. Radiation safety considerations in a positron tomography center [Abstract]. J Nucl Med Technol 1994;22:115.
    • (1994) J Nucl Med Technol , vol.22 , pp. 115
    • Browa, T.F.1    Yasillo, N.J.2    Kronmal, S.L.3
  • 4
    • 0024453845 scopus 로고
    • Automated quantitation of three-dimensional cardiac positron emission tomography for routine clinical use
    • Hicks K, Ganti G, Mullani N, et al. Automated quantitation of three-dimensional cardiac positron emission tomography for routine clinical use. J Nucl Med 1989;30:1787-1797.
    • (1989) J Nucl Med , vol.30 , pp. 1787-1797
    • Hicks, K.1    Ganti, G.2    Mullani, N.3
  • 5
    • 0026673178 scopus 로고
    • Radiation protection design for a clinical positron emission tomography imaging suite
    • Kearfott KJ, Carey JE, Clemenshaw MN, et al. Radiation protection design for a clinical positron emission tomography imaging suite. Health Phys 1992;63:581-589.
    • (1992) Health Phys , vol.63 , pp. 581-589
    • Kearfott, K.J.1    Carey, J.E.2    Clemenshaw, M.N.3
  • 6
    • 0011079485 scopus 로고
    • Regional cerebral blood flow during acquisition of a procedural memory
    • Metz J, Singh J, Gabrieli JDE, et al. Regional cerebral blood flow during acquisition of a procedural memory [Abstract]: Society for Neuroscience Abstracts 1993;19:1001.
    • (1993) Society for Neuroscience Abstracts , vol.19 , pp. 1001
    • Metz, J.1    Singh, J.2    Gabrieli, J.D.E.3
  • 8
    • 0027325049 scopus 로고
    • Radiation dose to positron emission tomography technologists during quantitative versus quantitative studies
    • McCormick VA, Mildos JA. Radiation dose to positron emission tomography technologists during quantitative versus quantitative studies. J Nucl Med 1993;34:769-772.
    • (1993) J Nucl Med , vol.34 , pp. 769-772
    • McCormick, V.A.1    Mildos, J.A.2
  • 9
    • 0024236133 scopus 로고
    • Cataracts induced by microwave and ionizing radiation
    • Lipman RM, Tripathi BJ, Tripathi RC. Cataracts induced by microwave and ionizing radiation [Review]. Surv Ophthalmol 1988;33:200-210.
    • (1988) Surv Ophthalmol , vol.33 , pp. 200-210
    • Lipman, R.M.1    Tripathi, B.J.2    Tripathi, R.C.3
  • 14
    • 0343222919 scopus 로고    scopus 로고
    • 15O] water synthesis and administration unit for multiple intravenous injection
    • 15O] water synthesis and administration unit for multiple intravenous injection [Abstract]. J Nucl Med Technol 1996;24:163.
    • (1996) J Nucl Med Technol , vol.24 , pp. 163
    • Ruszkiewicz, J.A.1    Simpson, N.R.2    Milko, D.L.3
  • 15
    • 0343222918 scopus 로고
    • Hand exposures from PET radiopharmaceuticals can be reduced easily and economically
    • Richmond JCW, Hichwa BD, Watkins GL. Hand exposures from PET radiopharmaceuticals can be reduced easily and economically [Abstract]. J Nucl Med Technol 1992;20:105.
    • (1992) J Nucl Med Technol , vol.20 , pp. 105
    • Richmond, J.C.W.1    Hichwa, B.D.2    Watkins, G.L.3
  • 16
    • 0343222923 scopus 로고
    • Reducing radiation exposure by utilizing a new injection device
    • Gaskill M, McCormick V, Kondas D, et al. Reducing radiation exposure by utilizing a new injection device. J Nucl Med Technol 1995;23:122-123.
    • (1995) J Nucl Med Technol , vol.23 , pp. 122-123
    • Gaskill, M.1    McCormick, V.2    Kondas, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.