메뉴 건너뛰기




Volumn 2, Issue 2, 1997, Pages 106-113

Mechanical strength and bone bonding of a titanium fiber mesh block for intervertebral fusion

Author keywords

biomaterials; intervertebral fusion; titanium fiber mesh block

Indexed keywords

TITANIUM;

EID: 0031007005     PISSN: 09492658     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF02489521     Document Type: Article
Times cited : (11)

References (30)
  • 1
    • 85030295997 scopus 로고
    • Human cancellous bone remodeling rates at the interface of porous coated implants
    • Orthopaedic Research Society Feb 15-18 San Francisco
    • Bloebaum RD, Bachus KN, Momberger NG, et al. Human cancellous bone remodeling rates at the interface of porous coated implants. In: Proceedings of the 39th annual meeting, Orthopaedic Research Society Feb 15-18 1993, San Francisco, 221.
    • (1993) Proceedings of the 39th Annual Meeting , pp. 221
    • Bloebaum, R.D.1    Bachus, K.N.2    Momberger, N.G.3
  • 2
    • 0018970317 scopus 로고
    • The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone
    • Bobyn JD, Pilliar RM, Cameron HU, et al. The optimum pore size for the fixation of porous-surfaced metal implants by the ingrowth of bone. Clin Orthop 1980;150.263-70.
    • (1980) Clin Orthop , vol.150 , pp. 263-270
    • Bobyn, J.D.1    Pilliar, R.M.2    Cameron, H.U.3
  • 3
    • 0342520229 scopus 로고
    • The histology of bone ingrowth at the implant/bone interface under known amounts of micromotion
    • Orthopaedic Research Society Feb 15-18 San Francisco
    • Bragdon CR, Jasty M, Lowenstein JD, et al. The histology of bone ingrowth at the implant/bone interface under known amounts of micromotion. In: Proceedings of the 39th annual meeting, Orthopaedic Research Society Feb 15-18 1993, San Francisco, 468.
    • (1993) Proceedings of the 39th Annual Meeting , pp. 468
    • Bragdon, C.R.1    Jasty, M.2    Lowenstein, J.D.3
  • 4
    • 0025818502 scopus 로고
    • A carbon fiber implant to aid interbody lumbar fusion mechanical testing
    • Brantigan JW, Steffee AD, Geiger JM. A carbon fiber implant to aid interbody lumbar fusion mechanical testing. Spine 1991;16:S277-82.
    • (1991) Spine , vol.16
    • Brantigan, J.W.1    Steffee, A.D.2    Geiger, J.M.3
  • 5
    • 0021013840 scopus 로고
    • Deformation of the vertebral end-plate under axial loading of the spine
    • Brinckmann P, Frobin W, Hierholzer E, et al. Deformation of the vertebral end-plate under axial loading of the spine. Spine 1983;8:851-6.
    • (1983) Spine , vol.8 , pp. 851-856
    • Brinckmann, P.1    Frobin, W.2    Hierholzer, E.3
  • 7
    • 0018111134 scopus 로고
    • The mechanical behavior of porous austenitic stainless steel fibre structures
    • Ducheyne P, Aernoudt E, de Meester P. The mechanical behavior of porous austenitic stainless steel fibre structures. J Materials Science 1978;13:2650-8.
    • (1978) J Materials Science , vol.13 , pp. 2650-2658
    • Ducheyne, P.1    Aernoudt, E.2    De Meester, P.3
  • 8
    • 0014983592 scopus 로고
    • Sintered fiber metal composites as a basis for attachment of implants to bone
    • Galante J, Rostoker W, Lueck R, et al. Sintered fiber metal composites as a basis for attachment of implants to bone. J Bone Joint Surg Am 1971;53:101-14
    • (1971) J Bone Joint Surg Am , vol.53 , pp. 101-114
    • Galante, J.1    Rostoker, W.2    Lueck, R.3
  • 9
    • 0015786401 scopus 로고
    • Fiber metal composites in the fixation of skeletal prosthesis
    • Galante J, Rostoker W. Fiber metal composites in the fixation of skeletal prosthesis. J Biomed Mater Res Symposium 1973;4:43-61
    • (1973) J Biomed Mater Res Symposium , vol.4 , pp. 43-61
    • Galante, J.1    Rostoker, W.2
  • 10
    • 0344454567 scopus 로고
    • Anterior lumbar spinal body fusion with the addition of A-O screwing and wiring
    • Hirabayashi K, Wakano K, Suzuki N, et al. Anterior lumbar spinal body fusion with the addition of A-O screwing and wiring. Neuro-Orthopedics 1986;2:15-20.
    • (1986) Neuro-Orthopedics , vol.2 , pp. 15-20
    • Hirabayashi, K.1    Wakano, K.2    Suzuki, N.3
  • 11
    • 0023989591 scopus 로고
    • Experimental studies on titanium fiber metal implant for spine fusion
    • in Japanese
    • Hoshijima K, Yamamoto H, Yamashita H. Experimental studies on titanium fiber metal implant for spine fusion. J Jpn Orthop Assoc 1988;62:399-413 (in Japanese).
    • (1988) J Jpn Orthop Assoc , vol.62 , pp. 399-413
    • Hoshijima, K.1    Yamamoto, H.2    Yamashita, H.3
  • 12
    • 85030298024 scopus 로고
    • Mechanical properties of pre-compressed titanium fiber metal implant
    • in Japanese
    • Hoshijima K, Yamamoto H, Kamioka Y, et al. Mechanical properties of pre-compressed titanium fiber metal implant. J Jpn Soc Clin Biomechanics Related Res 1992;14:429-35 (in Japanese).
    • (1992) J Jpn Soc Clin Biomechanics Related Res , vol.14 , pp. 429-435
    • Hoshijima, K.1    Yamamoto, H.2    Kamioka, Y.3
  • 14
    • 0028299389 scopus 로고
    • Titanium-mesh block replacement of the intervertebral disk
    • Leong CY, Chow SP, Yau ACMC. Titanium-mesh block replacement of the intervertebral disk. Clin Orthop 1994;300:52-63.
    • (1994) Clin Orthop , vol.300 , pp. 52-63
    • Leong, C.Y.1    Chow, S.P.2    Yau, A.C.M.C.3
  • 15
    • 0027170485 scopus 로고
    • Age-related changes in the tensile properties of cortical bone
    • McCalden RW, McGeough JA, Barker MB, et al. Age-related changes in the tensile properties of cortical bone. J Bone Joint Surg Am 1993;75:1193-205.
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 1193-1205
    • McCalden, R.W.1    McGeough, J.A.2    Barker, M.B.3
  • 16
    • 0022093658 scopus 로고
    • A new glass-ceramic for bone replacement: Evaluation of its bonding to bone tissue
    • Nakamura T, Yamamuro T, Higashi S, et al. A new glass-ceramic for bone replacement: evaluation of its bonding to bone tissue. J Biomed Mater Res 1985;19:685-98.
    • (1985) J Biomed Mater Res , vol.19 , pp. 685-698
    • Nakamura, T.1    Yamamuro, T.2    Higashi, S.3
  • 17
    • 0343389856 scopus 로고
    • An experimental study on titanium fiber metal implant for spine fusion
    • in Japanese
    • Nakauchi M, Yamamoto H, Kamioka Y, et al. An experimental study on titanium fiber metal implant for spine fusion. Cent Jpn J Orthop Traumat 1991;34:1773-83. (in Japanese).
    • (1991) Cent Jpn J Orthop Traumat , vol.34 , pp. 1773-1783
    • Nakauchi, M.1    Yamamoto, H.2    Kamioka, Y.3
  • 18
    • 0016502834 scopus 로고
    • Metal prosthesis of the cervical vertebra
    • Ono K, Tada K. Metal prosthesis of the cervical vertebra. J Neurosurg 1975;42:562-6.
    • (1975) J Neurosurg , vol.42 , pp. 562-566
    • Ono, K.1    Tada, K.2
  • 19
    • 0021948556 scopus 로고
    • Biomechanical study of cervical spine stabilization with methylmethacrylate
    • Panjabi MM, Goel VK, Clark CR, et al Biomechanical study of cervical spine stabilization with methylmethacrylate. Spine 1985;10:198-203.
    • (1985) Spine , vol.10 , pp. 198-203
    • Panjabi, M.M.1    Goel, V.K.2    Clark, C.R.3
  • 20
    • 0343391079 scopus 로고
    • Posterior lumbar interbody fusions by implanted threaded titanium cages
    • White AH, Schofferman JA, editors. St. Louis: Mosby
    • Ray CD Posterior lumbar interbody fusions by implanted threaded titanium cages. In: White AH, Schofferman JA, editors. Spine care, vol. 2. St. Louis: Mosby, 1995:1223-32.
    • (1995) Spine Care , vol.2 , pp. 1223-1232
    • Ray, C.D.1
  • 21
    • 0027294027 scopus 로고
    • Load-bearing capacity of corticocancellous bone grafts in the spine
    • Smith MD, Cody DD. Load-bearing capacity of corticocancellous bone grafts in the spine. J Bone Joint Surg Am 1993;75:1206-13.
    • (1993) J Bone Joint Surg Am , vol.75 , pp. 1206-1213
    • Smith, M.D.1    Cody, D.D.2
  • 22
    • 0026832935 scopus 로고
    • Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions
    • Søballe K, Hansen ES, Rasmussen HB, et al Tissue ingrowth into titanium and hydroxyapatite-coated implants during stable and unstable mechanical conditions. J Orthop Res 1992;10:285-99.
    • (1992) J Orthop Res , vol.10 , pp. 285-299
    • Søballe, K.1    Hansen, E.S.2    Rasmussen, H.B.3
  • 24
    • 0025305563 scopus 로고
    • Ventral interbody spondylodesis using a new plug-shaped implant
    • Stender W, Meißner HJ, Thomas W. Ventral interbody spondylodesis using a new plug-shaped implant. Neurosurg Rev 1990;13:25-34.
    • (1990) Neurosurg Rev , vol.13 , pp. 25-34
    • Stender, W.1    Meißner, H.J.2    Thomas, W.3
  • 25
    • 0023912594 scopus 로고
    • Treatment of metastatic disease of the spine with anterior resection and stabilization by means of a new cancellous metal construct
    • Waisbrod H. Treatment of metastatic disease of the spine with anterior resection and stabilization by means of a new cancellous metal construct. Arch Orthop Trauma Surg 1988;107:222-5.
    • (1988) Arch Orthop Trauma Surg , vol.107 , pp. 222-225
    • Waisbrod, H.1
  • 26
    • 0025010087 scopus 로고
    • Compressive strength of autologous and allogenous bone grafts for thoracolumbar and cervical spine fusion
    • Wittenberg RH, Moeller J, Shea M, et al. Compressive strength of autologous and allogenous bone grafts for thoracolumbar and cervical spine fusion. Spine 1990;15:1073-8.
    • (1990) Spine , vol.15 , pp. 1073-1078
    • Wittenberg, R.H.1    Moeller, J.2    Shea, M.3
  • 27
    • 85030299586 scopus 로고
    • Development of titanium fiber metal implant for anterior spine fusion and clinical use for the lumbar spine
    • in Japanese
    • Yamamoto H, Kamioka Y, Hoshijima K, et al. Development of titanium fiber metal implant for anterior spine fusion and clinical use for the lumbar spine. Rinshou Seikei Geka (Clin Orthop) 1992;27:521-7 (in Japanese).
    • (1992) Rinshou Seikei Geka (Clin Orthop) , vol.27 , pp. 521-527
    • Yamamoto, H.1    Kamioka, Y.2    Hoshijima, K.3
  • 28
    • 0025835752 scopus 로고
    • Lumbar spine interbody fusion with reinforced hydroxyapatite implants
    • Ylinen P, Kinnunen J, Laasonen EM, et al. Lumbar spine interbody fusion with reinforced hydroxyapatite implants. Arch Orthop Trauma Surg 1991;110:250-6
    • (1991) Arch Orthop Trauma Surg , vol.110 , pp. 250-256
    • Ylinen, P.1    Kinnunen, J.2    Laasonen, E.M.3
  • 29
    • 0023758434 scopus 로고
    • Microtrauma in the lumbar spine: A cause of low back pain
    • Yoganandan N, Maiman DJ, Pintar F, et al. Microtrauma in the lumbar spine: A cause of low back pain. Neurosurgery 1988;23:162-7.
    • (1988) Neurosurgery , vol.23 , pp. 162-167
    • Yoganandan, N.1    Maiman, D.J.2    Pintar, F.3
  • 30


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.