메뉴 건너뛰기




Volumn 133, Issue 5, 1997, Pages 596-598

Detection of unsuspected myocardial necrosis by rapid bedside assay for cardiac troponin T

Author keywords

[No Author keywords available]

Indexed keywords

CREATINE KINASE MB; TROPONIN T;

EID: 0031005703     PISSN: 00028703     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-8703(97)70156-X     Document Type: Article
Times cited : (87)

References (9)
  • 1
    • 0026092511 scopus 로고
    • Diagnostic efficiency of troponin T measurements in acute myocardial infarction
    • HA Katus A Remppis FJ Neumann T Scheffold KW Diederich G Vinar Diagnostic efficiency of troponin T measurements in acute myocardial infarction Circulation 83 1991 902 912
    • (1991) Circulation , vol.83 , pp. 902-912
    • Katus, HA1    Remppis, A2    Neumann, FJ3    Scheffold, T4    Diederich, KW5    Vinar, G6
  • 2
    • 0026708834 scopus 로고
    • Cardiac troponin T in the diagnosis of myocardial injury
    • J Mair F Dienstl B. Puschendorf Cardiac troponin T in the diagnosis of myocardial injury Crit Rev Clin Lab Sci 29 1992 31 57
    • (1992) Crit Rev Clin Lab Sci , vol.29 , pp. 31-57
    • Mair, J1    Dienstl, F2    Puschendorf, B.3
  • 3
    • 0028798940 scopus 로고
    • Development and characterization of a rapid assay for bedside determinations of cardiac troponin T
    • M Muller-Bardorff H Freitag T Scheffold A Remppis W Kubler HA. Katus Development and characterization of a rapid assay for bedside determinations of cardiac troponin T Circulation 92 1995 2869 2875
    • (1995) Circulation , vol.92 , pp. 2869-2875
    • Muller-Bardorff, M1    Freitag, H2    Scheffold, T3    Remppis, A4    Kubler, W5    Katus, HA.6
  • 4
    • 0028921658 scopus 로고
    • Independent prognostic value of serum creatine kinase isoenzyme MB mass, cardiac troponin T and myosin light chain levels in suspected acute myocardial infarction. Analysis of 28 months of follow-up in 196 patients
    • J Ravkilde H Nissen M Horder K. Thygesen Independent prognostic value of serum creatine kinase isoenzyme MB mass, cardiac troponin T and myosin light chain levels in suspected acute myocardial infarction. Analysis of 28 months of follow-up in 196 patients J Am Coll Cardiol 25 1995 574 581
    • (1995) J Am Coll Cardiol , vol.25 , pp. 574-581
    • Ravkilde, J1    Nissen, H2    Horder, M3    Thygesen, K.4
  • 6
    • 0028832202 scopus 로고
    • Prognostic value of cardiac troponin T in unstable angina pectoris
    • AHB Wu SA Abbas S Green L Pearsall S Dhakam R Azar Prognostic value of cardiac troponin T in unstable angina pectoris Am J Cardiol 76 1995 970 972
    • (1995) Am J Cardiol , vol.76 , pp. 970-972
    • Wu, AHB1    Abbas, SA2    Green, S3    Pearsall, L4    Dhakam, S5    Azar, R6
  • 7
    • 0028966417 scopus 로고
    • Evaluation of a rapid bedside assay for detection of serum cardiac troponin T
    • EM Antman C Grudzien DB. Sacks Evaluation of a rapid bedside assay for detection of serum cardiac troponin T JAMA 273 1995 1279 1282
    • (1995) JAMA , vol.273 , pp. 1279-1282
    • Antman, EM1    Grudzien, C2    Sacks, DB.3
  • 8
    • 0026648371 scopus 로고
    • Creatine kinase-MB
    • FS. Apple Creatine kinase-MB Lab Med 23 1992 298 302
    • (1992) Lab Med , vol.23 , pp. 298-302
    • Apple, FS.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.