메뉴 건너뛰기




Volumn 24, Issue 6, 1997, Pages 925-928

Theoretical analysis of error propagation in triple-energy absorptiometry: Application to measurement of lead in bone in vivo

Author keywords

Absorptiometry; Bone mass; Tissue decomposition; Triple energy

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; BONE; ERROR STATISTICS; JACOBIAN MATRICES; LIGHT ABSORPTION; STATISTICAL MECHANICS; TISSUE;

EID: 0031004520     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.597986     Document Type: Article
Times cited : (3)

References (11)
  • 1
    • 0026080670 scopus 로고
    • Theoretical and experimental limits of triple photon energy absorptiometry in the measurement of bone mineral
    • P. O. Kotzki, D. Mariano-Goulart, and M. Rossi, "Theoretical and experimental limits of triple photon energy absorptiometry in the measurement of bone mineral," Phys. Med. Biol. 36, 429-37 (1991)
    • (1991) Phys. Med. Biol. , vol.36 , pp. 429-437
    • Kotzki, P.O.1    Mariano-Goulart, D.2    Rossi, M.3
  • 2
    • 0025388760 scopus 로고
    • Triple photon absorptiometry cannot correct for fat inhomogeneities in lumbar spine bone mineral measurements
    • T. J. Farrell and C. E. Webber, "Triple photon absorptiometry cannot correct for fat inhomogeneities in lumbar spine bone mineral measurements" Clin. Phys. Physiol. Meas. 11, 77-84 (1990).
    • (1990) Clin. Phys. Physiol. Meas. , vol.11 , pp. 77-84
    • Farrell, T.J.1    Webber, C.E.2
  • 4
    • 0019515645 scopus 로고
    • Three-beam K-edge imaging of iodine using differences between fluoroscopic video images: Theoretical considerations
    • S. J. Riederer, R. A. Kruger and C. A. Mistretta, "Three-beam K-edge imaging of iodine using differences between fluoroscopic video images: Theoretical considerations," Med. Phys. 8, 471-479 (1981).
    • (1981) Med. Phys. , vol.8 , pp. 471-479
    • Riederer, S.J.1    Kruger, R.A.2    Mistretta, C.A.3
  • 5
    • 33744589024 scopus 로고    scopus 로고
    • An absorptiometric approach for measurement of lead in bone
    • F. Mourtada, T. Beck, and J. Links, "An absorptiometric approach for measurement of lead in bone," Med. Phys. 23, 1065 (1996).
    • (1996) Med. Phys. , vol.23 , pp. 1065
    • Mourtada, F.1    Beck, T.2    Links, J.3
  • 6
    • 0026091293 scopus 로고
    • Bone mineral densitometry with x-ray and radionuclide sources: A theoretical comparison
    • D. P. Chakraborty and G. T. Barnes, "Bone mineral densitometry with x-ray and radionuclide sources: A theoretical comparison," Med. Phys 18, 978-984 (1991).
    • (1991) Med. Phys , vol.18 , pp. 978-984
    • Chakraborty, D.P.1    Barnes, G.T.2
  • 7
    • 0023621941 scopus 로고
    • Performance characteristics of a dualenergy detector for digital scan projection radiography
    • D. R. Morgan and R. A. Sones, "Performance characteristics of a dualenergy detector for digital scan projection radiography," Med. Phys. 14, 728-735 (1987).
    • (1987) Med. Phys. , vol.14 , pp. 728-735
    • Morgan, D.R.1    Sones, R.A.2
  • 8
    • 0017108614 scopus 로고
    • Energy-selective reconstructions in x-ray computerized tomography
    • A. Alverz and A. Macovski, "Energy-selective reconstructions in x-ray computerized tomography," Phys. Med. Biol. 21, 733-744 (1976).
    • (1976) Phys. Med. Biol. , vol.21 , pp. 733-744
    • Alverz, A.1    Macovski, A.2
  • 10
    • 85027240855 scopus 로고    scopus 로고
    • Hospital of University of Pennsylvania (private communication)
    • D. P Chakraborty, Hospital of University of Pennsylvania (private communication)
    • Chakraborty, D.P.1
  • 11
    • 0027712249 scopus 로고
    • In vivo measurements of lead in bone using a 109Cd 'spot' source
    • A. Todd and F. McNeill, "In vivo measurements of lead in bone using a 109Cd 'spot' source," Basic Life Sci. 60, 299-302 (1993)
    • (1993) Basic Life Sci. , vol.60 , pp. 299-302
    • Todd, A.1    McNeill, F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.