메뉴 건너뛰기




Volumn 23, Issue 3, 1997, Pages 425-436

Deconvolution process in measurement of arterial velocity profiles via an ultrasonic pulsed Doppler velocimeter for evaluation of the wall shear rate

Author keywords

Arteries; Convolution; Deconvolution; Pulsed Doppler ultrasound; Velocity profiles; Wall shear rate

Indexed keywords

BLOOD VESSELS; COMPUTER SIMULATION; FLOW VISUALIZATION; ULTRASONIC DOPPLER VELOCIMETERS; ULTRASONIC VELOCITY MEASUREMENT;

EID: 0031004238     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(96)00200-1     Document Type: Article
Times cited : (16)

References (13)
  • 1
    • 4243858864 scopus 로고
    • Noninvasive ultrasonic flowmetry
    • Hwang NHC, Normann NA, eds. Baltimore: University Park
    • Baker DW, Daigle RE. Noninvasive ultrasonic flowmetry. In: Hwang NHC, Normann NA, eds. Cardiovascular flow dynamics and measurements. Baltimore: University Park, 1977:151-189.
    • (1977) Cardiovascular Flow Dynamics and Measurements , pp. 151-189
    • Baker, D.W.1    Daigle, R.E.2
  • 2
    • 0016012184 scopus 로고
    • The characteristics of the pulsed ultrasonic Doppler flowmeter
    • Dodwell RB, ed ch; Vannah WE, Wayland H, eds. Pittsburgh: Instrument Society of America
    • Baker DW, Jorgensen JE, Campau DN. The characteristics of the pulsed ultrasonic Doppler flowmeter. In: Dodwell RB, ed ch; Vannah WE, Wayland H, eds. Flow, its measurement and control in science and industry; Biological fluid flows, vol. 1, pt. 3. Pittsburgh: Instrument Society of America, 1974:1389-1400.
    • (1974) Flow, Its Measurement and Control in Science and Industry; Biological Fluid Flows , vol.1 , Issue.3 PART , pp. 1389-1400
    • Baker, D.W.1    Jorgensen, J.E.2    Campau, D.N.3
  • 3
    • 0026390815 scopus 로고
    • Non-traumatic study of the arterial system by indirect determination of clinical parameters: A theoretical linear model
    • Brebbia CA, Ouazar D, Bensari D, eds. Southampton: Computational Mechanics Publications
    • Bensalah A, Flaud P. Non-traumatic study of the arterial system by indirect determination of clinical parameters: A theoretical linear model. In: Brebbia CA, Ouazar D, Bensari D, eds. Computer method in water resources II: Computer aided engineering in water resources, vol. 3. Southampton: Computational Mechanics Publications, 1991:241-252.
    • (1991) Computer Method in Water Resources II: Computer Aided Engineering in Water Resources , vol.3 , pp. 241-252
    • Bensalah, A.1    Flaud, P.2
  • 4
    • 25844456020 scopus 로고
    • Ultrasonic indirect arterial wall shear rate measurement. Comparison between a centre-line velocity method and curve fitting of velocity profiles: Effects of the convolution
    • Held KD, Brebbia CA, Ciskowski RD, Power H, eds.
    • Bensalah A, Flaud P. Ultrasonic indirect arterial wall shear rate measurement. Comparison between a centre-line velocity method and curve fitting of velocity profiles: Effects of the convolution. In: Held KD, Brebbia CA, Ciskowski RD, Power H, eds. Computational biomedicine II. Southampton: Computational Mechanics Publications, 1993:292-300.
    • (1993) Computational Biomedicine II. Southampton: Computational Mechanics Publications , pp. 292-300
    • Bensalah, A.1    Flaud, P.2
  • 5
    • 0342763813 scopus 로고
    • Les méthodes de déconvolution et leurs limitations fondamentales
    • Biraud YG. Les méthodes de déconvolution et leurs limitations fondamentales. Rev Phys App 1976;11:203-214.
    • (1976) Rev Phys App , vol.11 , pp. 203-214
    • Biraud, Y.G.1
  • 6
    • 0027240986 scopus 로고
    • High-precision MR velocity mapping by 3D-Fourier phase encoding with a small number of encoding steps
    • Bittoun J, Bourroul E, Jolivet O, et al. High-precision MR velocity mapping by 3D-Fourier phase encoding with a small number of encoding steps. Magn Reson Med 1993;29:674-680.
    • (1993) Magn Reson Med , vol.29 , pp. 674-680
    • Bittoun, J.1    Bourroul, E.2    Jolivet, O.3
  • 7
    • 0016071215 scopus 로고
    • Analytical calibration of pulsed ultrasonic Doppler flowmeter
    • Jorgensen JE, Garbini JL. Analytical calibration of pulsed ultrasonic Doppler flowmeter. ASME Trans J Fluid Mech 1974;73-WA/610-1:158-167.
    • (1974) ASME Trans J Fluid Mech , vol.73 WA-610-1 , pp. 158-167
    • Jorgensen, J.E.1    Garbini, J.L.2
  • 9
    • 0026557260 scopus 로고
    • Mechanical deformation of vessel wall and shear stress determine the basal release of endothelium-derived relaxing factor in the intact rabbit coronary vascular bed
    • Lamontagne D, Pohl U, Busse R. Mechanical deformation of vessel wall and shear stress determine the basal release of endothelium-derived relaxing factor in the intact rabbit coronary vascular bed. Circ Res 1992;70:123-130.
    • (1992) Circ Res , vol.70 , pp. 123-130
    • Lamontagne, D.1    Pohl, U.2    Busse, R.3
  • 10
    • 0027579039 scopus 로고
    • Errors in the estimation of arterial wall shear rates that result from curve fitting of velocity proflies
    • Lou Z, Yang WJ, Stein PD. Errors in the estimation of arterial wall shear rates that result from curve fitting of velocity proflies. J Biomech 1993;26:383-390.
    • (1993) J Biomech , vol.26 , pp. 383-390
    • Lou, Z.1    Yang, W.J.2    Stein, P.D.3
  • 12
    • 0026911059 scopus 로고
    • Vascular fluid mechanics, the arterial wall, and atherosclerosis
    • Nerem RM. Vascular fluid mechanics, the arterial wall, and atherosclerosis. J Biomech Eng 1992;114:274-282.
    • (1992) J Biomech Eng , vol.114 , pp. 274-282
    • Nerem, R.M.1
  • 13
    • 0001850186 scopus 로고
    • Theoretical and practical aspects of pulsed Doppler flowmetry: Realtime application to the measure of instantaneous velocity profiles in vitro and in vivo
    • Reneman RS, ed. Amsterdam: North-Holland Publishing Company
    • Péronneau PA, Bournat JP, Bugnon A, Barbet A, Xhaard MC. Theoretical and practical aspects of pulsed Doppler flowmetry: Realtime application to the measure of instantaneous velocity profiles in vitro and in vivo. In: Reneman RS, ed. Cardiovascular applications of ultrasound. Amsterdam: North-Holland Publishing Company, 1974a:66-84.
    • (1974) Cardiovascular Applications of Ultrasound , pp. 66-84
    • Péronneau, P.A.1    Bournat, J.P.2    Bugnon, A.3    Barbet, A.4    Xhaard, M.C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.