메뉴 건너뛰기




Volumn 29, Issue 4, 1997, Pages 553-559

Long-term vascular access for hemodialysis using silicon dual-lumen catheters with guidewire replacement of catheters for technique salvage

Author keywords

dialysis catheter; Hemodialysis vascular access

Indexed keywords

SILICON;

EID: 0031003638     PISSN: 02726386     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0272-6386(97)90337-1     Document Type: Article
Times cited : (41)

References (18)
  • 2
    • 0024242554 scopus 로고
    • Use of a silicon catheter with a Dacron cuff for dialysis short-term vascular access
    • Moss AH, McLaughlin MM, Lempert KD, Holley JL: Use of a silicon catheter with a Dacron cuff for dialysis short-term vascular access. Am J Kidney Dis 12:492-498, 1988
    • (1988) Am J Kidney Dis , vol.12 , pp. 492-498
    • Moss, A.H.1    McLaughlin, M.M.2    Lempert, K.D.3    Holley, J.L.4
  • 3
    • 0025094473 scopus 로고
    • Use of a silicon dual-lumen catheter with a Dacron cuff as a long-term vascular access for hemodialysis patients
    • Moss AH, Vasilakis C, Holley JL, Foulks CJ, Pillai K, McDowell DE: Use of a silicon dual-lumen catheter with a Dacron cuff as a long-term vascular access for hemodialysis patients. Am J Kidney Dis 16:211-215, 1990
    • (1990) Am J Kidney Dis , vol.16 , pp. 211-215
    • Moss, A.H.1    Vasilakis, C.2    Holley, J.L.3    Foulks, C.J.4    Pillai, K.5    McDowell, D.E.6
  • 4
    • 0025871822 scopus 로고
    • Five years experience with the Quinton Permcath for vascular access
    • Gibson SP, Mosquera D: Five years experience with the Quinton Permcath for vascular access. Nephrol Dial Transplant 6:269-274, 1991
    • (1991) Nephrol Dial Transplant , vol.6 , pp. 269-274
    • Gibson, S.P.1    Mosquera, D.2
  • 5
    • 0025240760 scopus 로고
    • The use of dual lumen jugular venous catheters as definitive long term access for haemodialysis
    • Blake PG, Huraib S, Wu G, Uldall PR: The use of dual lumen jugular venous catheters as definitive long term access for haemodialysis. Int J Artif Organs 13:26-31, 1990
    • (1990) Int J Artif Organs , vol.13 , pp. 26-31
    • Blake, P.G.1    Huraib, S.2    Wu, G.3    Uldall, P.R.4
  • 6
    • 0028941027 scopus 로고
    • Catheter-related sepsis complicating long-term, tunnelled central venous dialysis catheters: Management by guidewire exchange
    • Shaffer D: Catheter-related sepsis complicating long-term, tunnelled central venous dialysis catheters: Management by guidewire exchange. Am J Kidney Dis 25:593-596, 1995
    • (1995) Am J Kidney Dis , vol.25 , pp. 593-596
    • Shaffer, D.1
  • 8
    • 0001607443 scopus 로고
    • Haemodialysis by percutaneous catheterisation of the femoral artery and vein with regional heparinisation
    • Shaldon S, Chiandussi L, Higgs B: Haemodialysis by percutaneous catheterisation of the femoral artery and vein with regional heparinisation. Lancet 2:857, 1961
    • (1961) Lancet , vol.2 , pp. 857
    • Shaldon, S.1    Chiandussi, L.2    Higgs, B.3
  • 12
    • 0020635830 scopus 로고
    • Salvage operations for malfunctioning polytetrafluoroethylene hemodialysis access grafts
    • Etheredge EE, Haid SD, Maeser MN, Sicard GA, Anderson CB: Salvage operations for malfunctioning polytetrafluoroethylene hemodialysis access grafts. Surgery 94:464-470, 1983
    • (1983) Surgery , vol.94 , pp. 464-470
    • Etheredge, E.E.1    Haid, S.D.2    Maeser, M.N.3    Sicard, G.A.4    Anderson, C.B.5
  • 14
    • 0023499894 scopus 로고
    • PTFE grafts for hemodialysis access. Techniques for insertion and management of complications
    • Raju S: PTFE grafts for hemodialysis access. Techniques for insertion and management of complications. Ann Surg 206:666-673, 1987
    • (1987) Ann Surg , vol.206 , pp. 666-673
    • Raju, S.1
  • 15
    • 0015379043 scopus 로고
    • Heart failure as a consequence of hemodialysis arteriovenous fistula
    • Ahearn DJ, Maher JF: Heart failure as a consequence of hemodialysis arteriovenous fistula. Ann Intern Med 77:201-204, 1972
    • (1972) Ann Intern Med , vol.77 , pp. 201-204
    • Ahearn, D.J.1    Maher, J.F.2
  • 16
    • 0017283309 scopus 로고
    • High-output congestive failure from femoral arteriovenous shunts for vascular access
    • Fee HJ, Levisman J, Doud RB, Golding AL: High-output congestive failure from femoral arteriovenous shunts for vascular access. Ann Surg 183:321-323, 1976
    • (1976) Ann Surg , vol.183 , pp. 321-323
    • Fee, H.J.1    Levisman, J.2    Doud, R.B.3    Golding, A.L.4
  • 17
    • 0025941317 scopus 로고
    • Post catheterisation vein stenosis in hemodialysis: Comparative angiographic study of 50 subclavian and 50 internal jugular accesses
    • Schillinger F, Schillinger D, Montagnac R, Milcent T: Post catheterisation vein stenosis in hemodialysis: Comparative angiographic study of 50 subclavian and 50 internal jugular accesses. Nephrol Dial Transplant 6:722-724, 1991
    • (1991) Nephrol Dial Transplant , vol.6 , pp. 722-724
    • Schillinger, F.1    Schillinger, D.2    Montagnac, R.3    Milcent, T.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.