메뉴 건너뛰기




Volumn 72, Issue 1 SUPPL., 1997, Pages

Fetal pulse oximetry - A preliminary report on sensor precision determined by dual sensor studies

Author keywords

Fetal pulse; Oximetry

Indexed keywords

CLINICAL ARTICLE; CLINICAL TRIAL; CONFERENCE PAPER; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FETUS; FETUS CONTROL; FETUS MONITORING; HUMAN; OXYGEN SATURATION; PRIORITY JOURNAL; PULSE OXIMETRY;

EID: 0031000747     PISSN: 03012115     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-2115(97)02716-4     Document Type: Conference Paper
Times cited : (13)

References (15)
  • 1
    • 0343605132 scopus 로고    scopus 로고
    • EFM alone vs. intermittent auscultation in labour
    • Autumn Record 3298
    • Grant A. EFM alone vs. intermittent auscultation in labour. In: Oxford Database of Perinatal Trials. Version 1.3, Disk Issue 8, Autumn 1992. Record 3298.
    • Oxford Database of Perinatal Trials. Version 1.3 , Issue.DISK ISSUE 8 , pp. 1992
    • Grant, A.1
  • 2
    • 0029049174 scopus 로고
    • Efficacy and safety of intrapartum electronic fetal monitoring: An update
    • Thacker SB, Stroup DF, Peterson HB. Efficacy and safety of intrapartum electronic fetal monitoring: an update. Obstet Gynecol. 1995; 86(4 Pt 1): 613-620.
    • (1995) Obstet Gynecol. , vol.86 , Issue.4 PT 1 , pp. 613-620
    • Thacker, S.B.1    Stroup, D.F.2    Peterson, H.B.3
  • 3
    • 0026594040 scopus 로고
    • Fetal oxygen saturation measurement by transmission pulse oximetry
    • Buschmann J, Rall G, Knitza R. Fetal oxygen saturation measurement by transmission pulse oximetry. Lancet. 1992; 339: 615.
    • (1992) Lancet , vol.339 , pp. 615
    • Buschmann, J.1    Rall, G.2    Knitza, R.3
  • 4
    • 0023749517 scopus 로고
    • Continuous intrapartum measurement of fetal oxygen saturation
    • Peat S, Booker M, Lanigan C, Ponte J. Continuous intrapartum measurement of fetal oxygen saturation. Lancet. 1988; 2: 213.
    • (1988) Lancet , vol.2 , pp. 213
    • Peat, S.1    Booker, M.2    Lanigan, C.3    Ponte, J.4
  • 5
    • 0023749301 scopus 로고
    • Continuous intrapartum measurement of fetal oxygen saturation
    • Johnson N, Lilford RJ. Continuous intrapartum measurement of fetal oxygen saturation. Lancet. 1988; 2: 517.
    • (1988) Lancet , vol.2 , pp. 517
    • Johnson, N.1    Lilford, R.J.2
  • 6
  • 7
    • 0025969123 scopus 로고
    • The effects of caput succedaneum on oxygen saturation measurements
    • Schram CMH, Gardosi JO. The effects of caput succedaneum on oxygen saturation measurements. Br J Obstet Gynaecol 1991; 98: 113-114.
    • (1991) Br J Obstet Gynaecol , vol.98 , pp. 113-114
    • Schram, C.M.H.1    Gardosi, J.O.2
  • 8
    • 0028341399 scopus 로고
    • Artifacts in fetal pulse oximetry: Incomplete sensor-to-skin contact
    • Gardosi JO, Damianou D, Schram C. Artifacts in fetal pulse oximetry: incomplete sensor-to-skin contact. Am J Obstet Gynecol 1994; 170(4): 1169-73.
    • (1994) Am J Obstet Gynecol , vol.170 , Issue.4 , pp. 1169-1173
    • Gardosi, J.O.1    Damianou, D.2    Schram, C.3
  • 9
    • 0025858240 scopus 로고
    • The accuracy of fetal pulse oximetry in the second stage of labour
    • Johnson N, Johnson V, Bannister J. Lilford R. The accuracy of fetal pulse oximetry in the second stage of labour. J Perinat Med 1991; 19(4): 297-303.
    • (1991) J Perinat Med , vol.19 , Issue.4 , pp. 297-303
    • Johnson, N.1    Johnson, V.2    Bannister, J.3    Lilford, R.4
  • 10
    • 0025646523 scopus 로고
    • The effect of meconium on neonatal and fetal reflectance pulse oximetry
    • Johnson N, Johnson VA, Bannister J, McNamara H. The effect of meconium on neonatal and fetal reflectance pulse oximetry. J Perinat Med 1990; 18(5): 351-355.
    • (1990) J Perinat Med , vol.18 , Issue.5 , pp. 351-355
    • Johnson, N.1    Johnson, V.A.2    Bannister, J.3    McNamara, H.4
  • 11
    • 0029150015 scopus 로고
    • The effect of uterine contractions on fetal oxygen saturation
    • McNamara H, Johnson N. The effect of uterine contractions on fetal oxygen saturation. Br J Obstet Gynaecol 1995; 102(8): 644-647.
    • (1995) Br J Obstet Gynaecol , vol.102 , Issue.8 , pp. 644-647
    • McNamara, H.1    Johnson, N.2
  • 12
    • 0028278292 scopus 로고
    • Artifacts in fetal pulse oximetry: Nonarterial pulsatile signals
    • Schram CM, Gardosi JO. Artifacts in fetal pulse oximetry: nonarterial pulsatile signals. Am J Obstet Gynecol 1994; 170(4): 1174-1177.
    • (1994) Am J Obstet Gynecol , vol.170 , Issue.4 , pp. 1174-1177
    • Schram, C.M.1    Gardosi, J.O.2
  • 13
    • 0002794690 scopus 로고
    • Reflectance Pulse Oximetry (RPOX): Two sensors compared in piglets
    • Nijland R, Jongsma HW, Nijhuis JG. Reflectance Pulse Oximetry (RPOX): two sensors compared in piglets. Am J Obstet Gynecol 1995; 172(1): 365.
    • (1995) Am J Obstet Gynecol , vol.1721 , pp. 365
    • Nijland, R.1    Jongsma, H.W.2    Nijhuis, J.G.3
  • 14
    • 0024414277 scopus 로고
    • The penumbra effect: Vasomotion dependent pulse oximeter artefact due to probe malposition
    • Kelleher JF, Ruff RH. The penumbra effect: vasomotion dependent pulse oximeter artefact due to probe malposition. Anesthesiology 1989; 71: 787-791.
    • (1989) Anesthesiology , vol.71 , pp. 787-791
    • Kelleher, J.F.1    Ruff, R.H.2
  • 15
    • 0029935778 scopus 로고    scopus 로고
    • Human fetal intrapartum oxygen saturation monitoring. Agreement between readings from two sensors on the same fetus
    • East CE, Colditz PB, Dunster KR, Khoo SK. Human fetal intrapartum oxygen saturation monitoring. Agreement between readings from two sensors on the same fetus. Am J Obstet Gynecol 1996; 174(5): 1594-1598.
    • (1996) Am J Obstet Gynecol , vol.174 , Issue.5 , pp. 1594-1598
    • East, C.E.1    Colditz, P.B.2    Dunster, K.R.3    Khoo, S.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.