메뉴 건너뛰기




Volumn 70, Issue 1-4, 1997, Pages 139-142

Analysis of acceptance testing data for more than 800 sheets of CR-39 plastic assessed for the DRPS approved neutron dosimetry service

Author keywords

[No Author keywords available]

Indexed keywords

PLASTIC;

EID: 0030994778     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a031929     Document Type: Conference Paper
Times cited : (7)

References (7)
  • 1
    • 8244248437 scopus 로고    scopus 로고
    • An Assessment of Two Types of Personal Neutron Dosemeter which Utilize the AUTOSCAN 60 Automatic Etch-Track Reading System
    • Weeks, A. R., Ford, T. D. and Harvey, J. R. An Assessment of Two Types of Personal Neutron Dosemeter which Utilize the AUTOSCAN 60 Automatic Etch-Track Reading System. Nuclear Electric Report TEPZ/REP/0084/93.
    • Nuclear Electric Report TEPZ/REP/0084/93
    • Weeks, A.R.1    Ford, T.D.2    Harvey, J.R.3
  • 2
    • 7344251930 scopus 로고
    • An Assessment of Thermal Neutron Sensitivity Dosemeters Based on a Commercial Etched Track Reading System
    • W. Koelzer and R. Maushart
    • Wilson, M., French, A., Harvey, J. R. and Wernli, C. An Assessment of Thermal Neutron Sensitivity Dosemeters Based on a Commercial Etched Track Reading System. In: Strahlenschutz: Physik und Messtechnik (W. Koelzer and R. Maushart) 2, 529-534 (1994).
    • (1994) Strahlenschutz: Physik und Messtechnik , vol.2 , pp. 529-534
    • Wilson, M.1    French, A.2    Harvey, J.R.3    Wernli, C.4
  • 3
    • 0030937631 scopus 로고    scopus 로고
    • An Automated Neutron Dosimetry System Based on the Chemical Etch of CR39
    • Harvey, J. R., French, A. P., Jackson, M., Renouf, M. C. and Weeks, A. R. An Automated Neutron Dosimetry System Based on the Chemical Etch of CR39. Radiat. Prot. Dosim. 70(1-4), 149-152 (This issue) (1997).
    • (1997) Radiat. Prot. Dosim. , vol.70 , Issue.1-4 THIS ISSUE , pp. 149-152
    • Harvey, J.R.1    French, A.P.2    Jackson, M.3    Renouf, M.C.4    Weeks, A.R.5
  • 4
    • 0029233586 scopus 로고
    • Some Environmental Trial Results for a Planar and Isotropic Neutron Dosemeter
    • Jackson, M., French, A., Harvey, J. R. and Weeks, A. R. Some Environmental Trial Results for a Planar and Isotropic Neutron Dosemeter. Radiat. Meas. 25(1-4), 461-462 (1995).
    • (1995) Radiat. Meas. , vol.25 , Issue.1-4 , pp. 461-462
    • Jackson, M.1    French, A.2    Harvey, J.R.3    Weeks, A.R.4
  • 5
    • 0023635140 scopus 로고
    • The Bristol University Neutron Dosimetry System
    • Worley, A., Fews, A. P. and Henshaw, D. L. The Bristol University Neutron Dosimetry System. Radiat. Prot. Dosim. 20(1-2), 95-98 (1987).
    • (1987) Radiat. Prot. Dosim. , vol.20 , Issue.1-2 , pp. 95-98
    • Worley, A.1    Fews, A.P.2    Henshaw, D.L.3
  • 6
    • 0025930020 scopus 로고
    • 1990 Recommendations of the International Commission on Radiological Protection
    • Publication 60. Oxford: Pergamon
    • ICRP. 1990 Recommendations of the International Commission on Radiological Protection. Publication 60. Ann ICRP 21(1-3) (Oxford: Pergamon) (1990).
    • (1990) Ann ICRP , vol.21 , Issue.1-3
  • 7
    • 0023618445 scopus 로고
    • The NRPB PADC Neutron Personal Dosimetry Service
    • Gilvin, P. J., Bartlett, D. T. and Steele, J. D. The NRPB PADC Neutron Personal Dosimetry Service Radiat. Prot. Dosim. 20(1-2), 99-102 (1987).
    • (1987) Radiat. Prot. Dosim. , vol.20 , Issue.1-2 , pp. 99-102
    • Gilvin, P.J.1    Bartlett, D.T.2    Steele, J.D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.