메뉴 건너뛰기




Volumn 11, Issue 3, 1997, Pages 485-492

Valve replacement in the small aortic annulus: Prospective randomized trial of st. Jude with Medtronic Hall

Author keywords

Medtronic Hall valves; Prosthetic valve replacement; Randomized trial; SJM valve; Small aortic annulus

Indexed keywords

AORTA VALVE PROSTHESIS; AORTA VALVE REPLACEMENT; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; FEMALE; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL;

EID: 0030983045     PISSN: 10107940     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1010-7940(96)01088-3     Document Type: Article
Times cited : (15)

References (18)
  • 1
    • 0025081208 scopus 로고
    • Clinical performance of St. Jude and Medtronic Hall prostheses: A randomized comparative study
    • Antunes MJ. Clinical performance of St. Jude and Medtronic Hall prostheses: a randomized comparative study. Ann Thorac Surg 1990;50:743-747.
    • (1990) Ann Thorac Surg , vol.50 , pp. 743-747
    • Antunes, M.J.1
  • 2
    • 0028065258 scopus 로고
    • Long term clinical outcome with small size standard St. Jude medical valves implanted in the aortic position
    • Arom KV, Goldenberg IF, Emery RW. Long term clinical outcome with small size standard St. Jude medical valves implanted in the aortic position. J Heart Valve Dis 1994;3:531-536.
    • (1994) J Heart Valve Dis , vol.3 , pp. 531-536
    • Arom, K.V.1    Goldenberg, I.F.2    Emery, R.W.3
  • 4
    • 33845382806 scopus 로고
    • Nonparametric estimation from incomplete observations
    • Kaplan, EL, Meier P. Nonparametric estimation from incomplete observations, J Am Stat Assoc 1958;53:457-481.
    • (1958) J Am Stat Assoc , vol.53 , pp. 457-481
    • Kaplan, E.L.1    Meier, P.2
  • 5
    • 0027954114 scopus 로고
    • Causes of sudden cardiac death in patients with replacement valves: An autopsy study
    • Burke AP, Farb A, Sessums L, Virmani R. Causes of sudden cardiac death in patients with replacement valves: an autopsy study. J Heart Valve Dis 1994;3:10-16.
    • (1994) J Heart Valve Dis , vol.3 , pp. 10-16
    • Burke, A.P.1    Farb, A.2    Sessums, L.3    Virmani, R.4
  • 6
    • 0028314992 scopus 로고
    • The significance of sudden and unwitnessed death after heart valve replacement
    • Butchart EG. The significance of sudden and unwitnessed death after heart valve replacement. J Heart Valve Dis 1994;3:1-4.
    • (1994) J Heart Valve Dis , vol.3 , pp. 1-4
    • Butchart, E.G.1
  • 8
    • 0019954722 scopus 로고
    • Early clinical evaluation after aortic valve replacement with the St. Jude medical valve in patients with a small aortic root
    • Gill CC, King HC, Lytle BW, Cosgrove DM, Golding LAR, Loop FD. Early clinical evaluation after aortic valve replacement with the St. Jude medical valve in patients with a small aortic root. Circulation Supp I 1982;66:147-149.
    • (1982) Circulation Supp I , vol.66 , pp. 147-149
    • Gill, C.C.1    King, H.C.2    Lytle, B.W.3    Cosgrove, D.M.4    Golding, L.A.R.5    Loop, F.D.6
  • 10
    • 0028914551 scopus 로고
    • Up to 30 year survival after aortic valve replacement in the small aortic root
    • He G, Grunkemeier GL, Gately HL, Furnary AP, Starr A. Up to 30 year survival after aortic valve replacement in the small aortic root. Ann Thorac Surg 1995;59:1056-1062.
    • (1995) Ann Thorac Surg , vol.59 , pp. 1056-1062
    • He, G.1    Grunkemeier, G.L.2    Gately, H.L.3    Furnary, A.P.4    Starr, A.5
  • 11
    • 0025173702 scopus 로고
    • Clinical experience with the Medtronic Hall valve prosthesis
    • Keenan RJ, Armitage JM, Trento A. Clinical experience with the Medtronic Hall valve prosthesis. Ann Thorac Surg 1990;50:748-753.
    • (1990) Ann Thorac Surg , vol.50 , pp. 748-753
    • Keenan, R.J.1    Armitage, J.M.2    Trento, A.3
  • 13
    • 0026041982 scopus 로고
    • Doppler echocardiography in 180 normally functioning St. Jude medical aortic valve prostheses. Early and late postoperative assessments
    • Penn EC, Jin BS, DeCastro CM, Ferguson JJ, Hall RJ. Doppler echocardiography in 180 normally functioning St. Jude medical aortic valve prostheses. Early and late postoperative assessments. Chest 1991;100:988-990.
    • (1991) Chest , vol.100 , pp. 988-990
    • Penn, E.C.1    Jin, B.S.2    DeCastro, C.M.3    Ferguson, J.J.4    Hall, R.J.5
  • 15
    • 0028249325 scopus 로고
    • Influence of prosthesis size on change in left ventricular mass following aortic valve replacement
    • Sim EKW, Orszulak TA, Schaff HV, Shub C. Influence of prosthesis size on change in left ventricular mass following aortic valve replacement. Eur J Cardio-thorac Surg 1994;8:293-297.
    • (1994) Eur J Cardio-thorac Surg , vol.8 , pp. 293-297
    • Sim, E.K.W.1    Orszulak, T.A.2    Schaff, H.V.3    Shub, C.4
  • 18
    • 0019460867 scopus 로고
    • Hemodynamic evaluation of the St. Jude medical valve prosthesis in the small aortic annulus
    • Wortham DC, Tri TB, Bowen TE. Hemodynamic evaluation of the St. Jude medical valve prosthesis in the small aortic annulus. J Thorac Cardiovasc Surg 1981;81:615-620.
    • (1981) J Thorac Cardiovasc Surg , vol.81 , pp. 615-620
    • Wortham, D.C.1    Tri, T.B.2    Bowen, T.E.3