메뉴 건너뛰기




Volumn 10, Issue 4 I, 1997, Pages 419-427

Ambulatory blood pressure monitoring editing criteria. Is standardization needed?

Author keywords

blood pressure monitoring; blood pressure variability; editing criteria; microalbuminuria

Indexed keywords

ADULT; AMBULATORY MONITORING; ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DIASTOLIC BLOOD PRESSURE; FEMALE; HUMAN; HYPERTENSION; INFORMATION PROCESSING; MAJOR CLINICAL STUDY; MALE; MICROALBUMINURIA; PRIORITY JOURNAL; REPRODUCIBILITY; STANDARDIZATION; SYSTOLIC BLOOD PRESSURE; TECHNIQUE;

EID: 0030981349     PISSN: 08957061     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0895-7061(96)00453-0     Document Type: Article
Times cited : (53)

References (41)
  • 1
    • 0026473183 scopus 로고
    • Ambulatory blood pressure monitoring: A critical review of the current methods to handle outliers
    • Berardi L, Chau NP, Chanudet X, et al: Ambulatory blood pressure monitoring: a critical review of the current methods to handle outliers. J Hypertens 1992; 10:1243-1248.
    • (1992) J Hypertens , vol.10 , pp. 1243-1248
    • Berardi, L.1    Chau, N.P.2    Chanudet, X.3
  • 2
    • 0026036331 scopus 로고
    • Reproducibility of non-invasive and intra-arterial blood pressure monitoring: Implications for studies on antihypertensive treatment
    • Trazzi S, Mutti E, Frattola A, et al: Reproducibility of non-invasive and intra-arterial blood pressure monitoring: implications for studies on antihypertensive treatment. J Hypertens 1991;9:115-119.
    • (1991) J Hypertens , vol.9 , pp. 115-119
    • Trazzi, S.1    Mutti, E.2    Frattola, A.3
  • 3
    • 0021281140 scopus 로고
    • The circadian blood pressure pattern in ambulatory normal subjects
    • Weber MA, Drayer JI, Nakamura DK, et al: The circadian blood pressure pattern in ambulatory normal subjects. Am J Cardiol 1984;54:115-119.
    • (1984) Am J Cardiol , vol.54 , pp. 115-119
    • Weber, M.A.1    Drayer, J.I.2    Nakamura, D.K.3
  • 4
    • 0020585552 scopus 로고
    • The prognostic value of ambulatory blood pressure
    • Perleff D, Sokolow M, Cowan R: The prognostic value of ambulatory blood pressure. JAMA 1983;249:2792-2798.
    • (1983) JAMA , vol.249 , pp. 2792-2798
    • Perleff, D.1    Sokolow, M.2    Cowan, R.3
  • 5
    • 0023695845 scopus 로고
    • Relationship between ambulatory and exercise blood pressure and cardiac structure
    • Devereux RB, Pickering TG: Relationship between ambulatory and exercise blood pressure and cardiac structure. Am Heart J 1988;116:1124-1133.
    • (1988) Am Heart J , vol.116 , pp. 1124-1133
    • Devereux, R.B.1    Pickering, T.G.2
  • 6
    • 0028134828 scopus 로고
    • Factors related to the presence of microalbuminuria in essential hypertension
    • Redon J, Liao Y, Lozano JV, et al: Factors related to the presence of microalbuminuria in essential hypertension. Am J Hypertens 1994;7:801-807.
    • (1994) Am J Hypertens , vol.7 , pp. 801-807
    • Redon, J.1    Liao, Y.2    Lozano, J.V.3
  • 7
    • 0023527322 scopus 로고
    • Blood pressure and organ damage
    • Zanchetti A, Mancia G: Blood pressure and organ damage. J Cardiovasc Pharmacology 1987;10(suppl 6):111-118.
    • (1987) J Cardiovasc Pharmacology , vol.10 , Issue.6 SUPPL. , pp. 111-118
    • Zanchetti, A.1    Mancia, G.2
  • 8
    • 0002263549 scopus 로고
    • Proteinuria and hypertension
    • Ritz E, Nowicki M, Fliser D, et al: Proteinuria and hypertension. Kidney Int 1994;47(suppl):76-80.
    • (1994) Kidney Int , vol.47 , Issue.SUPPL. , pp. 76-80
    • Ritz, E.1    Nowicki, M.2    Fliser, D.3
  • 9
    • 0025273923 scopus 로고
    • Ambulatory blood pressure monitoring and echocardiographic left ventricular wall thickness and mass
    • Prisant LM, Carr AA: Ambulatory blood pressure monitoring and echocardiographic left ventricular wall thickness and mass. Am J Hypertens 1990;3:81-89.
    • (1990) Am J Hypertens , vol.3 , pp. 81-89
    • Prisant, L.M.1    Carr, A.A.2
  • 10
    • 0028238745 scopus 로고
    • Microalbuminuria in 411 untreated individuals with established hypertension, white coat hypertension, and normotension
    • Hoegholm A, Bang LE, Kristensen KS, et al: Microalbuminuria in 411 untreated individuals with established hypertension, white coat hypertension, and normotension. Hypertension 1994;24:101-105.
    • (1994) Hypertension , vol.24 , pp. 101-105
    • Hoegholm, A.1    Bang, L.E.2    Kristensen, K.S.3
  • 11
    • 0026710368 scopus 로고
    • The role of ambulatory monitoring of the blood pressure for the assessment of antihypertensive agents
    • White WB: The role of ambulatory monitoring of the blood pressure for the assessment of antihypertensive agents. J Clin Pharmacol 1992;32:524-528.
    • (1992) J Clin Pharmacol , vol.32 , pp. 524-528
    • White, W.B.1
  • 12
    • 0002297047 scopus 로고
    • The Hypertension and Ambulatory Recording Venetia Study (HAR-VEST): A trial on the predictive value of ambulatory blood pressure monitoring for the development of fixed hypertension in patients with borderline hypertension
    • Palatini P, Pessina AC, Dal Palù C: The Hypertension and Ambulatory Recording Venetia Study (HAR-VEST): a trial on the predictive value of ambulatory blood pressure monitoring for the development of fixed hypertension in patients with borderline hypertension. High Blood Press 1993;2:11-18.
    • (1993) High Blood Press , vol.2 , pp. 11-18
    • Palatini, P.1    Pessina, A.C.2    Dal Palù, C.3
  • 13
    • 0026340805 scopus 로고
    • A multicenter evaluation of the A&D TM-2420 ambulatory blood pressure recorder
    • White WB, Pickering TG, Morganroth J, et al: A multicenter evaluation of the A&D TM-2420 ambulatory blood pressure recorder. Am J Hypertens 1991; 4:890-896.
    • (1991) Am J Hypertens , vol.4 , pp. 890-896
    • White, W.B.1    Pickering, T.G.2    Morganroth, J.3
  • 14
    • 0000065032 scopus 로고
    • Validation of the accuracy of the a & D TM-2420 model 7 for ambulatory blood pressure monitoring and effect of microphone replacement on its performance
    • Palatini P, Penzo M, Canali C, et al: Validation of the accuracy of the A & D TM-2420 model 7 for ambulatory blood pressure monitoring and effect of microphone replacement on its performance. J Amb Monitor 1991; 4:281-288.
    • (1991) J Amb Monitor , vol.4 , pp. 281-288
    • Palatini, P.1    Penzo, M.2    Canali, C.3
  • 15
    • 0026806250 scopus 로고
    • Clinical relevance of night-time blood pressure and of daytime blood pressure variability
    • Palatini P, Penzo M, Racioppa A, et al: Clinical relevance of night-time blood pressure and of daytime blood pressure variability. Arch Intern Med 1992; 152:1855-1860.
    • (1992) Arch Intern Med , vol.152 , pp. 1855-1860
    • Palatini, P.1    Penzo, M.2    Racioppa, A.3
  • 16
    • 0029587754 scopus 로고
    • Relationship between albumin excretion rate, ambulatory blood pressure and left ventricular hypertrophy in mild hypertension
    • Palatini P, Graniero GR, Canali C, et al: Relationship between albumin excretion rate, ambulatory blood pressure and left ventricular hypertrophy in mild hypertension. J Hypertens 1995;13:1796-1800.
    • (1995) J Hypertens , vol.13 , pp. 1796-1800
    • Palatini, P.1    Graniero, G.R.2    Canali, C.3
  • 17
    • 0001816125 scopus 로고
    • Performance reliability of the del Mar Avionics non-invasive ambulatory blood pressure instrument in clinical use
    • Kennedy HL, Padgett NE, Horan MJ. Performance reliability of the Del Mar Avionics non-invasive ambulatory blood pressure instrument in clinical use. Ambulatory Electrocardiology 1979;4:13-17.
    • (1979) Ambulatory Electrocardiology , vol.4 , pp. 13-17
    • Kennedy, H.L.1    Padgett, N.E.2    Horan, M.J.3
  • 18
    • 0024455331 scopus 로고
    • Non invasive ambulatory blood pressure monitoring in patients with recently detected systemic hypertension
    • Phillips RA, Goldman ME, Eison HB, et al: Non invasive ambulatory blood pressure monitoring in patients with recently detected systemic hypertension. Am J Cardiol 1989;64:62-64.
    • (1989) Am J Cardiol , vol.64 , pp. 62-64
    • Phillips, R.A.1    Goldman, M.E.2    Eison, H.B.3
  • 19
    • 0022254023 scopus 로고
    • Definition of normalcy in whole day ambulatory blood pressure monitoring
    • Drayer JM, Weber MA: Definition of normalcy in whole day ambulatory blood pressure monitoring. Clin Exp Hypertens [a] 1985;7:195-204.
    • (1985) Clin Exp Hypertens [A] , vol.7 , pp. 195-204
    • Drayer, J.M.1    Weber, M.A.2
  • 20
    • 0022380509 scopus 로고
    • The dilemma of mild hypertension
    • Drayer JM: The dilemma of mild hypertension. Chest 1985;88(suppl 3):1835-1865.
    • (1985) Chest , vol.88 , Issue.3 SUPPL. , pp. 1835-1865
    • Drayer, J.M.1
  • 21
    • 0023914111 scopus 로고
    • Effects of weight loss on clinic and ambulatory blood pressure in normotensive men
    • Fortmann SP, Haskell WL, Wood PD: Effects of weight loss on clinic and ambulatory blood pressure in normotensive men. Am J Cardiol 1988;62:89-93.
    • (1988) Am J Cardiol , vol.62 , pp. 89-93
    • Fortmann, S.P.1    Haskell, W.L.2    Wood, P.D.3
  • 22
    • 0024830684 scopus 로고
    • Race and gender influence ambulatory blood pressure patterns of adolescents
    • Harshfield GA, Alpert BS, Wiley ES, et al: Race and gender influence ambulatory blood pressure patterns of adolescents. Hypertension 1989;14:598-603.
    • (1989) Hypertension , vol.14 , pp. 598-603
    • Harshfield, G.A.1    Alpert, B.S.2    Wiley, E.S.3
  • 23
    • 0022592796 scopus 로고
    • Loss of nocturnal decline in blood pressure after cardiac transplantation
    • Reeves RA, Shapiro AP, Thompson ME, et al: Loss of nocturnal decline in blood pressure after cardiac transplantation. Circulation 1986;73:401-408.
    • (1986) Circulation , vol.73 , pp. 401-408
    • Reeves, R.A.1    Shapiro, A.P.2    Thompson, M.E.3
  • 24
    • 0021151583 scopus 로고
    • Detection of diurnal rhythm in arterial blood pressure in the evaluation of 24-hour antihypertensive therapy
    • Germanò G, Damiani S, Ciavarella M, et al: Detection of diurnal rhythm in arterial blood pressure in the evaluation of 24-hour antihypertensive therapy. Clin Cardiol 1984;7:525-535.
    • (1984) Clin Cardiol , vol.7 , pp. 525-535
    • Germanò, G.1    Damiani, S.2    Ciavarella, M.3
  • 25
    • 0021812125 scopus 로고
    • The amount of monitoring time required in determining a blood pressure profile
    • Germanò C, Ferrucci A, Damiani S, et al: The amount of monitoring time required in determining a blood pressure profile. Clin Exp Hypertens [A] 1985;7:361-364.
    • (1985) Clin Exp Hypertens [A] , vol.7 , pp. 361-364
    • Germanò, C.1    Ferrucci, A.2    Damiani, S.3
  • 26
    • 12644295670 scopus 로고
    • Non-invasive ambulatory arterial pressure measurement: Preliminary results
    • Herpin D, Benoist F, Amiel A, et al: Non-invasive ambulatory arterial pressure measurement: preliminary results. Sem Hop Paris 1987;22:199-205.
    • (1987) Sem Hop Paris , vol.22 , pp. 199-205
    • Herpin, D.1    Benoist, F.2    Amiel, A.3
  • 27
    • 0023720621 scopus 로고
    • Effects of ambulatory blood pressure monitoring on diagnosis and cost of treatment for mild hypertension
    • Krakoff LR, Eison H, Phillips RH, et al: Effects of ambulatory blood pressure monitoring on diagnosis and cost of treatment for mild hypertension. Am Heart J 1988; 116:1152-1154.
    • (1988) Am Heart J , vol.116 , pp. 1152-1154
    • Krakoff, L.R.1    Eison, H.2    Phillips, R.H.3
  • 28
    • 0024330890 scopus 로고
    • Effects of altitude exposure on 24 hour blood pressure and adrenergic activity
    • Palatini P, Businaro R, Berton G, et al: Effects of altitude exposure on 24 hour blood pressure and adrenergic activity. Am J Cardiol 1989;64:1379-1382.
    • (1989) Am J Cardiol , vol.64 , pp. 1379-1382
    • Palatini, P.1    Businaro, R.2    Berton, G.3
  • 29
    • 84944374730 scopus 로고
    • Blood pressure during normal daily activities, sleep and exercise
    • Pickering TG, Harshfield GA, Kleinert HD, et al: Blood pressure during normal daily activities, sleep and exercise. JAMA 1982;247:992-996.
    • (1982) JAMA , vol.247 , pp. 992-996
    • Pickering, T.G.1    Harshfield, G.A.2    Kleinert, H.D.3
  • 30
    • 0023132932 scopus 로고
    • A data-based method for bivariate outlier detection: Application to automatic blood pressure recording devices
    • Clark LA, Denby L, Pregibon D, et al: A data-based method for bivariate outlier detection: application to automatic blood pressure recording devices. Psychophysiology 1987;24(1):119-125.
    • (1987) Psychophysiology , vol.24 , Issue.1 , pp. 119-125
    • Clark, L.A.1    Denby, L.2    Pregibon, D.3
  • 31
    • 0024379373 scopus 로고
    • Twentyfour hour ambulatory blood pressure in shift workers
    • Chau NP, Mallion JM, De Gaudemaris R, et al: Twentyfour hour ambulatory blood pressure in shift workers. Circulation 1989;80:341-347.
    • (1989) Circulation , vol.80 , pp. 341-347
    • Chau, N.P.1    Mallion, J.M.2    De Gaudemaris, R.3
  • 32
    • 0021984373 scopus 로고
    • Monitoring 24-hour blood pressure in a drug trial. Evaluation of a non-invasive device
    • Berglund G, De Faire U, Castendorf J, et al: Monitoring 24-hour blood pressure in a drug trial. Evaluation of a non-invasive device. Hypertension 1985;7:688-694.
    • (1985) Hypertension , vol.7 , pp. 688-694
    • Berglund, G.1    De Faire, U.2    Castendorf, J.3
  • 33
    • 12644287210 scopus 로고
    • Ambulatory measurement of arterial pressure. Evaluation of a new SpaceLabs automatic device
    • Mallion JM, Safar M (eds): Squibb Medical Systems, Grenoble, France
    • De Gaudemaris R, Battistella P, Siché J-P, et al: Ambulatory measurement of arterial pressure. Evaluation of a new SpaceLabs automatic device, in Mallion JM, Safar M (eds): Ambulatory Measurement of Arterial Pressure - SpaceLabs Procedure. Squibb Medical Systems, Grenoble, France, 1985, pp 21-28.
    • (1985) Ambulatory Measurement of Arterial Pressure - SpaceLabs Procedure , pp. 21-28
    • De Gaudemaris, R.1    Battistella, P.2    Siché, J.-P.3
  • 34
    • 0024213847 scopus 로고
    • A method to define reference profiles for ambulatory blood pressure, with application to blood pressure profiles in 158 young normal subjects
    • Chau NP, Chanudet X, Larroque P: A method to define reference profiles for ambulatory blood pressure, with application to blood pressure profiles in 158 young normal subjects. Clin Exp Hypertens [A] 1988;10:951-969.
    • (1988) Clin Exp Hypertens [A] , vol.10 , pp. 951-969
    • Chau, N.P.1    Chanudet, X.2    Larroque, P.3
  • 35
    • 0027944889 scopus 로고
    • Differential effects of doxazosin on clinic and ambulatory pressure according to age, gender, and presence of white coat hypertension. results of the HALT study
    • Pickering TG, Levenstein M, Walmsley P: Differential effects of doxazosin on clinic and ambulatory pressure according to age, gender, and presence of white coat hypertension. results of the HALT study. Am J Hypertens 1994;7:848-852.
    • (1994) Am J Hypertens , vol.7 , pp. 848-852
    • Pickering, T.G.1    Levenstein, M.2    Walmsley, P.3
  • 36
    • 0026021202 scopus 로고
    • Ambulatory blood pressure monitoring in clinical trials
    • Staessen J, Fagard R, Liinen P, et al: Ambulatory blood pressure monitoring in clinical trials. J Hypertens 1991; 9(suppl 1):S13-S19.
    • (1991) J Hypertens , vol.9 , Issue.1 SUPPL.
    • Staessen, J.1    Fagard, R.2    Liinen, P.3
  • 37
    • 0024238477 scopus 로고
    • 24-hour blood pressure monitoring: Evaluation of Spacelabs 5300 monitor by comparison with intra-arterial recording in ambulant subjects
    • Casadei R, Parati G, Pomidossi G, et al: 24-hour blood pressure monitoring: evaluation of Spacelabs 5300 monitor by comparison with intra-arterial recording in ambulant subjects. J Hypertens 1988;6:797-803.
    • (1988) J Hypertens , vol.6 , pp. 797-803
    • Casadei, R.1    Parati, G.2    Pomidossi, G.3
  • 38
    • 0028142747 scopus 로고
    • Ambulatory pressure decreases on long-term placebo treatment in older patients with isolated systolic hypertension
    • Staessen JA, Thijs L, Clement D, et al: Ambulatory pressure decreases on long-term placebo treatment in older patients with isolated systolic hypertension. J Hypertens 1994;12;1035-1039.
    • (1994) J Hypertens , vol.12 , pp. 1035-1039
    • Staessen, J.A.1    Thijs, L.2    Clement, D.3
  • 39
    • 0025636474 scopus 로고
    • Consensus document on non-invasive ambulatory blood pressure monitoring
    • The Scientific Committee: Consensus document on non-invasive ambulatory blood pressure monitoring. J Hypertens 1990;8(suppl 6):135-140.
    • (1990) J Hypertens , vol.8 , Issue.6 SUPPL. , pp. 135-140
  • 40
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland MJ, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;i:307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, M.J.1    Altman, D.G.2
  • 41
    • 0028889736 scopus 로고
    • A consensus view on the technique of ambulatory blood pressure monitoring
    • Staessen JA, Fagard R, Thijs L, et al: A consensus view on the technique of ambulatory blood pressure monitoring. Hypertension 1995;26:912-918.
    • (1995) Hypertension , vol.26 , pp. 912-918
    • Staessen, J.A.1    Fagard, R.2    Thijs, L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.