메뉴 건너뛰기




Volumn 70, Issue 1-4, 1997, Pages 121-126

Future developments in the NRPB PADC neutron personal monitoring service

Author keywords

[No Author keywords available]

Indexed keywords

CONFERENCE PAPER; LABORATORY; NEUTRON DOSIMETRY; NEUTRON RADIATION; PERSONNEL RADIATION MONITORING; RADIATION DETECTOR; RADIATION DOSE; RADIATION PROTECTION; SIGNAL NOISE RATIO;

EID: 0030977693     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a031925     Document Type: Conference Paper
Times cited : (6)

References (14)
  • 1
    • 0022215969 scopus 로고
    • Development of a Single Element Neutron Personal Dosemeter for Thermal. Epithermal and Fast Neutrons
    • Bartlett, D. T., Steele, J. D. and Stubberfield, D. R. Development of a Single Element Neutron Personal Dosemeter for Thermal. Epithermal and Fast Neutrons. Nucl. Tracks 12, 645-648 (1986).
    • (1986) Nucl. Tracks , vol.12 , pp. 645-648
    • Bartlett, D.T.1    Steele, J.D.2    Stubberfield, D.R.3
  • 4
    • 0022237382 scopus 로고
    • Dosimetric Properties of Different CR-39 Plastics used as a Neutron Recoil Track Detector
    • Piesch, E. and Urban, M. Dosimetric Properties of Different CR-39 Plastics used as a Neutron Recoil Track Detector. Nucl. Tracks 12(1-6), 661-664 (1986).
    • (1986) Nucl. Tracks , vol.12 , Issue.1-6 , pp. 661-664
    • Piesch, E.1    Urban, M.2
  • 5
    • 0025867631 scopus 로고
    • Polymerisation, Structure and Track Recording Properties of CR-39
    • Ahmad, S. and Stejny, J. Polymerisation, Structure and Track Recording Properties of CR-39. Nucl. Tracks Radiat. Meas. 19, 11-16 (1991).
    • (1991) Nucl. Tracks Radiat. Meas. , vol.19 , pp. 11-16
    • Ahmad, S.1    Stejny, J.2
  • 6
    • 0000149760 scopus 로고
    • The Energy and Angle Dependence of Neutron Response for PADC Manufactured using Two Different Cure Cycles
    • Tanner, R. J., Bartlett, D. T. and Hager, L. G. The Energy and Angle Dependence of Neutron Response for PADC Manufactured using Two Different Cure Cycles. Radiat. Meas. 25(1-4), 467-468 (1995).
    • (1995) Radiat. Meas. , vol.25 , Issue.1-4 , pp. 467-468
    • Tanner, R.J.1    Bartlett, D.T.2    Hager, L.G.3
  • 7
    • 23544462582 scopus 로고
    • Limits for Qualitative Detection and Quantitative Determination: Application to Radiochemistry
    • Currie, L. A. Limits for Qualitative Detection and Quantitative Determination: Application to Radiochemistry. Anal. Chem. 40, 586-593 (1968).
    • (1968) Anal. Chem. , vol.40 , pp. 586-593
    • Currie, L.A.1
  • 8
    • 0027250560 scopus 로고
    • Uncertainty of Measurement and Lower Detection Limit of Track Etched Detector Systems: Experimental Verification and Consequences for Intercomparison Experiments
    • Burgkhardt, B., Piesch, E. K. A. and Vilgis, M. Uncertainty of Measurement and Lower Detection Limit of Track Etched Detector Systems: Experimental Verification and Consequences for Intercomparison Experiments. Radiat. Prot. Dosim. 47(1/4), 617-622 (1993).
    • (1993) Radiat. Prot. Dosim. , vol.47 , Issue.1-4 , pp. 617-622
    • Burgkhardt, B.1    Piesch, E.K.A.2    Vilgis, M.3
  • 9
    • 0003367889 scopus 로고
    • A New Criterion for Comparing Track Etch Dosimetry Systems
    • Tanner, R. J. and Bartlett, D T. A New Criterion for Comparing Track Etch Dosimetry Systems. Radiat. Meas. 25(1-4), 445-448 (1995).
    • (1995) Radiat. Meas. , vol.25 , Issue.1-4 , pp. 445-448
    • Tanner, R.J.1    Bartlett, D.T.2
  • 10
    • 0020239427 scopus 로고
    • A Curing Cycle for Detector Quality CR-39
    • Eds P. Fowler and V. M. Clapham (Oxford: Pergamon Press)
    • Adams, Jr, J. H. A Curing Cycle for Detector Quality CR-39. In: Solid State Nuclear Track Detectors. Eds P. Fowler and V. M. Clapham (Oxford: Pergamon Press) pp. 145-148 (1981).
    • (1981) Solid State Nuclear Track Detectors , pp. 145-148
    • Adams Jr., J.H.1
  • 11
    • 0025750446 scopus 로고
    • A Two Frequency Electrochemical Etch for Routine Processing of Neutron Dosemeters at the NRPB?
    • Tanner, R. J., Bartlett, D. T., Williams, S. M., Steele, J. D. and Dean. S. F. A Two Frequency Electrochemical Etch for Routine Processing of Neutron Dosemeters at the NRPB? Nucl. Tracks Radiat. Meas. 19(1-4), 217-220 (1991).
    • (1991) Nucl. Tracks Radiat. Meas. , vol.19 , Issue.1-4 , pp. 217-220
    • Tanner, R.J.1    Bartlett, D.T.2    Williams, S.M.3    Steele, J.D.4    Dean, S.F.5
  • 13
    • 0026475796 scopus 로고
    • Neutron Spectra, Radiological Quantities and Instrument and Dosemeter Responses at a Magnox Reactor and a Fuel Reprocessing Installation
    • Bartlett, D. T., Britcher, A. R., Bardell, A. G., Thomas, D. J. and Hudson, I. F. Neutron Spectra, Radiological Quantities and Instrument and Dosemeter Responses at a Magnox Reactor and a Fuel Reprocessing Installation. Radiat. Prot. Dosim. 44(1/4), 233-238 (1992).
    • (1992) Radiat. Prot. Dosim. , vol.44 , Issue.1-4 , pp. 233-238
    • Bartlett, D.T.1    Britcher, A.R.2    Bardell, A.G.3    Thomas, D.J.4    Hudson, I.F.5
  • 14
    • 0028895069 scopus 로고
    • Determination of Neutron and Photon Dose Equivalent at Workplaces in Nuclear Facilities in Sweden
    • Lindborg, L., Bartlett, D. T., Drake, P., Klein, H , Schmitz, Th. and Tichy, M. Determination of Neutron and Photon Dose Equivalent at Workplaces in Nuclear Facilities in Sweden. Radiat. Prot. Dosim. 61(1-3), 89-100 (1995).
    • (1995) Radiat. Prot. Dosim. , vol.61 , Issue.1-3 , pp. 89-100
    • Lindborg, L.1    Bartlett, D.T.2    Drake, P.3    Klein, H.4    Schmitz, Th.5    Tichy, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.