메뉴 건너뛰기




Volumn 70, Issue 1-4, 1997, Pages 83-86

Efficiencies of an SSNTD and an electronic neutron dosemeter with the same (n,α) (n,p) converter

Author keywords

[No Author keywords available]

Indexed keywords

SILICON;

EID: 0030974523     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/oxfordjournals.rpd.a032024     Document Type: Conference Paper
Times cited : (5)

References (9)
  • 1
    • 0024462851 scopus 로고
    • Neutron Dosimetry with CR-39 Track Detectors using Electrochemical Etching: Recent Improvements, Dosimetric Characteristics, and Aspects of Routine Application
    • Piesch, E., Al-Najjar, A. and Ninomiya, K. Neutron Dosimetry with CR-39 Track Detectors using Electrochemical Etching: Recent Improvements, Dosimetric Characteristics, and Aspects of Routine Application. Radiat. Prot. Dosim. 27, 215-230 (1989).
    • (1989) Radiat. Prot. Dosim. , vol.27 , pp. 215-230
    • Piesch, E.1    Al-Najjar, A.2    Ninomiya, K.3
  • 2
    • 0004298351 scopus 로고
    • Investigation of Individual Neutron Monitors on the Basis of Etched-track Detectors
    • PTB May
    • Alberts, W. G Investigation of Individual Neutron Monitors on the Basis of Etched-track Detectors. In: The 1990 Eurados-Cendos Exercise, PTB (May 1992).
    • (1992) The 1990 Eurados-Cendos Exercise
    • Alberts, W.G.1
  • 5
    • 0029772291 scopus 로고    scopus 로고
    • An Individual Neutron Dosemeter with (n,α) and (n,p) Converter
    • Zamani, M., Sampsonidis, D. and Savvidis, E. An Individual Neutron Dosemeter with (n,α) and (n,p) Converter. Radiat. Meas. 26, 87-92 (1996).
    • (1996) Radiat. Meas. , vol.26 , pp. 87-92
    • Zamani, M.1    Sampsonidis, D.2    Savvidis, E.3
  • 6
    • 8244227968 scopus 로고
    • PhD Thesis, Thessaloniki
    • Savvidis, E. PhD Thesis, Thessaloniki (1990).
    • (1990)
    • Savvidis, E.1
  • 7
    • 0029892372 scopus 로고    scopus 로고
    • A Real-Time Personal Neutron Dosemeter Based on PIPS Diodes and a Double Layer Neutron Convertner
    • Zamani, M. and Savvidis, E. A Real-Time Personal Neutron Dosemeter Based on PIPS Diodes and a Double Layer Neutron Convertner. Radiat. Prot. Dosim. 63, 299-303 (1996).
    • (1996) Radiat. Prot. Dosim. , vol.63 , pp. 299-303
    • Zamani, M.1    Savvidis, E.2
  • 8
    • 8244263263 scopus 로고
    • Separation of Albedo Neutron Component of a CR-39 Neutron Dosemeter during on Phantom Irradiation
    • Budapest
    • Savvidis, E., Sampsonidis, D. and Zamani, M. Separation of Albedo Neutron Component of a CR-39 Neutron Dosemeter during on Phantom Irradiation Presented at 11th Int. Symp. on Solid State Dosimetry, Budapest. 1995.
    • (1995) 11th Int. Symp. on Solid State Dosimetry
    • Savvidis, E.1    Sampsonidis, D.2    Zamani, M.3
  • 9
    • 0024400102 scopus 로고
    • A Proposed Procedure for Standardising the Relationship between the Directional Dose Equivalent and Neutron Fluence
    • Sieberg, B. R. L. and Morhart, A. A Proposed Procedure for Standardising the Relationship between the Directional Dose Equivalent and Neutron Fluence. Radiat. Prot. Dosim. 44, 47-51 (1989).
    • (1989) Radiat. Prot. Dosim. , vol.44 , pp. 47-51
    • Sieberg, B.R.L.1    Morhart, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.