Volumn 59, Issue 1, 1997, Pages 97-100

Percutaneous balloon valvuloplasty of stenosed mitral bioprosthesis

Author keywords

Bioprosthesis; Percutaneous balloon mitral valvuloplasty

Indexed keywords

ADULT; ARTICLE; BIOPROSTHESIS; CASE REPORT; ECHOCARDIOGRAPHY; ELECTROCARDIOGRAM; FEMALE; HUMAN; MITRAL VALVE STENOSIS; PRIORITY JOURNAL; SURGICAL TECHNIQUE; VALVULOPLASTY;

EID: 0030972362     PISSN: 01675273     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-5273(96)02898-7     Document Type: Article
Times cited : (8)

References (11)
  • 1
    • 0021358935 scopus 로고
    • Clinical application of transvenous mitral commissurotomy by a new balloon catheter
    • Inoue K, Owaki T, Takasumi, Kitamura F, Miyamoto F. Clinical application of transvenous mitral commissurotomy by a new balloon catheter. J Thorac Cardiovasc Surg 1984;87:394-402.
    • (1984) J Thorac Cardiovasc Surg , vol.87 , pp. 394-402
    • Inoue, K.1    Owaki, T.2    Takasumi3    Kitamura, F.4    Miyamoto, F.5
  • 2
    • 0023035352 scopus 로고
    • Reoperations for valve surgery: Perioperative mortality and determinants of risk for 1000 patients, 1958-84
    • Lytle BW, Cosgrove DM, Taylor PC et al. Reoperations for valve surgery: perioperative mortality and determinants of risk for 1000 patients, 1958-84. Ann Thorac Surg 1986;42:632-643.
    • (1986) Ann Thorac Surg , vol.42 , pp. 632-643
    • Lytle, B.W.1    Cosgrove, D.M.2    Taylor, P.C.3
  • 3
    • 0023628884 scopus 로고
    • Balloon percutaneous valvuloplasty for stenotic bioprosthetic valves in the mitral position
    • Calvo OL, Sobrino N, Gamallo C, Oliver J, Dominguez F, Iglesias A. Balloon percutaneous valvuloplasty for stenotic bioprosthetic valves in the mitral position. Am J Cardiol 1987;60:736-737.
    • (1987) Am J Cardiol , vol.60 , pp. 736-737
    • Calvo, O.L.1    Sobrino, N.2    Gamallo, C.3    Oliver, J.4    Dominguez, F.5    Iglesias, A.6
  • 4
    • 0024444809 scopus 로고
    • Improved quality of life after successful balloon valvuloplasty of a stenosed mitral bioprosthesis
    • Cox DA, Friedman PL, Selwyn AP, Lee RT, Bittl JA. Improved quality of life after successful balloon valvuloplasty of a stenosed mitral bioprosthesis. Am Heart J 1989;118:839-841.
    • (1989) Am Heart J , vol.118 , pp. 839-841
    • Cox, D.A.1    Friedman, P.L.2    Selwyn, A.P.3    Lee, R.T.4    Bittl, J.A.5
  • 8
    • 0022547144 scopus 로고
    • Percutaneous balloon valvuloplasty for stenosis of a porcine bioprosthesis in the tricuspid valve position
    • Feit F, Stecy PJ, Nachamie MS. Percutaneous balloon valvuloplasty for stenosis of a porcine bioprosthesis in the tricuspid valve position. Am J Cardiol 1986;58:363-364.
    • (1986) Am J Cardiol , vol.58 , pp. 363-364
    • Feit, F.1    Stecy, P.J.2    Nachamie, M.S.3
  • 9
    • 0025619383 scopus 로고
    • Percutaneous balloon valvuloplasty of a stenosed bioprosthesis (Carpentier-Edwards xenograft) in the tricuspid valve position
    • in Japanese
    • Hasegawa J, Kawachi K, Morita R et al. Percutaneous balloon valvuloplasty of a stenosed bioprosthesis (Carpentier-Edwards xenograft) in the tricuspid valve position. Kyobu Geka Jpn J Thorac Surg 1990;43:1046-1051 (in Japanese).
    • (1990) Kyobu Geka Jpn J Thorac Surg , vol.43 , pp. 1046-1051
    • Hasegawa, J.1    Kawachi, K.2    Morita, R.3
  • 10
    • 0023854796 scopus 로고
    • Problems encountered with catheter balloon valvuloplasty of bioprosthetic aortic valves
    • McKay CR, Waller BF, Hong R, Rubin N, Reid CL, Rahimtoola SH. Problems encountered with catheter balloon valvuloplasty of bioprosthetic aortic valves. Am Heart J 1988;115:463-465.
    • (1988) Am Heart J , vol.115 , pp. 463-465
    • McKay, C.R.1    Waller, B.F.2    Hong, R.3    Rubin, N.4    Reid, C.L.5    Rahimtoola, S.H.6
  • 11
    • 0028269286 scopus 로고
    • Balloon valvuloplasty is contraindicated in stenotic mitral bioprosthesis
    • Lin PJ, Chang JP, Chu JJ, Chang CH. Balloon valvuloplasty is contraindicated in stenotic mitral bioprosthesis. Am Heart J 1994;127:724-726.
    • (1994) Am Heart J , vol.127 , pp. 724-726
    • Lin, P.J.1    Chang, J.P.2    Chu, J.J.3    Chang, Ch.4