메뉴 건너뛰기




Volumn 98, Issue 3, 1997, Pages 640-647

A simplified statistical method for local INR using linear regression

Author keywords

INR; Linear regression; Orthogonal regression

Indexed keywords

PROTHROMBIN; THROMBOPLASTIN;

EID: 0030964596     PISSN: 00071048     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2141.1997.d01-3498.x     Document Type: Article
Times cited : (8)

References (16)
  • 2
    • 0026500229 scopus 로고
    • Assessment of value of calibrated lyophilized plasmas to determine International Sensitivity Index for coagulometers
    • Clarke, K., Taberner, D.A., Thomson, J.M., Morris, J.A. & Poller, L. (1992) Assessment of value of calibrated lyophilized plasmas to determine International Sensitivity Index for coagulometers. Journal of Clinical Pathology, 45, 58-60.
    • (1992) Journal of Clinical Pathology , vol.45 , pp. 58-60
    • Clarke, K.1    Taberner, D.A.2    Thomson, J.M.3    Morris, J.A.4    Poller, L.5
  • 4
    • 0002084937 scopus 로고
    • Fitting a straight line by least squares
    • J. Wiley & Sons, New York
    • Draper, N.R. & Smith, H. (1966) Fitting a straight line by least squares. Applied Regression Analysis, pp. 1-35. J. Wiley & Sons, New York.
    • (1966) Applied Regression Analysis , pp. 1-35
    • Draper, N.R.1    Smith, H.2
  • 5
    • 0001529736 scopus 로고
    • Procedure of reference calibrated plasmas for prothrombin time standardisation
    • Abstract, XIVth Congress of the International Society on Thrombosis and Haemostasis, New York
    • Houbouyan, L.L. & Goguel, A.F. (1993) Procedure of reference calibrated plasmas for prothrombin time standardisation. Abstract, XIVth Congress of the International Society on Thrombosis and Haemostasis, New York. Thrombosis and Haemostasis, 69, 663.
    • (1993) Thrombosis and Haemostasis , vol.69 , pp. 663
    • Houbouyan, L.L.1    Goguel, A.F.2
  • 9
    • 0024494004 scopus 로고
    • Effect of automation on the prothrombin time test in NEQAS surveys
    • Poller, L., Thomson, J.M. & Taberner, D.A. (1989) Effect of automation on the prothrombin time test in NEQAS surveys. Journal of Clinical Pathology, 42, 97-100.
    • (1989) Journal of Clinical Pathology , vol.42 , pp. 97-100
    • Poller, L.1    Thomson, J.M.2    Taberner, D.A.3
  • 10
    • 0028902973 scopus 로고
    • The value of plasma calibrants in correcting coagulometer effects on International Normalized Ratios
    • Poller, L., Triplett, D.A., Hirsh, J., Carroll, J. & Clarke, K. (1995a) The value of plasma calibrants in correcting coagulometer effects on International Normalized Ratios. American Journal of Clinical Pathology, 103, 358-365.
    • (1995) American Journal of Clinical Pathology , vol.103 , pp. 358-365
    • Poller, L.1    Triplett, D.A.2    Hirsh, J.3    Carroll, J.4    Clarke, K.5
  • 11
    • 0028910164 scopus 로고
    • A comparison of lyophilized artificially depleted plasmas and lyophilized plasmas from patients receiving warfarin in correcting for coagulometer effects on International Normalized Ratios
    • Poller, L., Triplett, D.A., Hirsh, J., Carroll, J. & Clarke, K. (1995b) A comparison of lyophilized artificially depleted plasmas and lyophilized plasmas from patients receiving warfarin in correcting for coagulometer effects on International Normalized Ratios. American Journal of Clinical Pathology, 103, 366-371.
    • (1995) American Journal of Clinical Pathology , vol.103 , pp. 366-371
    • Poller, L.1    Triplett, D.A.2    Hirsh, J.3    Carroll, J.4    Clarke, K.5
  • 12
    • 0025289048 scopus 로고
    • The dependence of the International Sensitivity Index on the coagulometer used to perform the prothrombin time
    • Ray, M.J. & Smith, I.R. (1990) The dependence of the International Sensitivity Index on the coagulometer used to perform the prothrombin time. Thrombosis and Haemostasis, 63, 424-429.
    • (1990) Thrombosis and Haemostasis , vol.63 , pp. 424-429
    • Ray, M.J.1    Smith, I.R.2
  • 13
    • 0027983871 scopus 로고
    • Use of lyophilized calibration plasmas and control blood for INR calculation in external quality assessment of the prothrombin time
    • van den Besselaar, A.M.H.P. (1994) Use of lyophilized calibration plasmas and control blood for INR calculation in external quality assessment of the prothrombin time. American Journal of Clinical Pathology, 102, 123-127.
    • (1994) American Journal of Clinical Pathology , vol.102 , pp. 123-127
    • Van Den Besselaar, A.M.H.P.1
  • 14
    • 0001847289 scopus 로고
    • Orthogonal regression equation
    • (ed. by A. M. H. P. van den Besselaar, H. R. Gralnick and S. M. Lewis), Martinus Nijhoff, Boston
    • van der Velde, E.A. (1984) Orthogonal regression equation. Thromboplastin Calibration and Oral Anticoagulation (ed. by A. M. H. P. van den Besselaar, H. R. Gralnick and S. M. Lewis), pp. 25-40. Martinus Nijhoff, Boston.
    • (1984) Thromboplastin Calibration and Oral Anticoagulation , pp. 25-40
    • Van Der Velde, E.A.1
  • 15
    • 0024356851 scopus 로고
    • Correction of instrument and reagent based differences in determination of the International Normalised Ratio (INR) for monitoring anticoagulant therapy
    • van Rijn, J.L.M.L., Schmidt Nico, A. & Rutten, W. (1989) Correction of instrument and reagent based differences in determination of the International Normalised Ratio (INR) for monitoring anticoagulant therapy. Clinical Chemistry, 355, 840-843.
    • (1989) Clinical Chemistry , vol.355 , pp. 840-843
    • Van Rijn, J.L.M.L.1    Schmidt Nico, A.2    Rutten, W.3
  • 16
    • 0004021630 scopus 로고
    • 33rd Report. W.H.O.
    • W.H.O. Expert Committee on Biological Standardisation (1983) 33rd Report. W.H.O. Technical Series, 687, 81-105.
    • (1983) Technical Series , vol.687 , pp. 81-105


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.