메뉴 건너뛰기




Volumn 70, Issue 1, 1997, Pages 95-97

Magnetic resonance imaging and spinal cord stimulation systems

Author keywords

magnetic resonance imaging; neurostimulators; spinal cord stimulation

Indexed keywords

ADULT; ARTICLE; CASE REPORT; FEMALE; HUMAN; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM PAIN; PRIORITY JOURNAL; SAFETY; SPINAL CORD STIMULATION;

EID: 0030963371     PISSN: 03043959     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0304-3959(96)03298-8     Document Type: Article
Times cited : (43)

References (7)
  • 1
    • 0019483220 scopus 로고
    • Potential hazards in NMR imaging: Heating effects of changing magnetic fields and RF fields on small metallic implants
    • Davis, P.L., Crooks, L., Arakawa, M. et al., Potential hazards in NMR imaging: heating effects of changing magnetic fields and RF fields on small metallic implants, Am. J. Roentgenol., 137 (1981) 857-860.
    • (1981) Am. J. Roentgenol. , vol.137 , pp. 857-860
    • Davis, P.L.1    Crooks, L.2    Arakawa, M.3
  • 2
    • 0022504514 scopus 로고
    • The effects of magnetic resonance imaging on implantable pulse generators
    • Holmes, D., Hayes, D., Gray, J. et al., The effects of magnetic resonance imaging on implantable pulse generators, PACE, 9 (1986) 360-370.
    • (1986) PACE , vol.9 , pp. 360-370
    • Holmes, D.1    Hayes, D.2    Gray, J.3
  • 3
    • 0028111486 scopus 로고
    • The value of published data on MR compatibility of metallic implants and devices
    • Kanal, E. and Shellock, F.G., The value of published data on MR compatibility of metallic implants and devices (review), Am. J. Neuroradiol., 15 (1994) 1394-1396.
    • (1994) Am. J. Neuroradiol. , vol.15 , pp. 1394-1396
    • Kanal, E.1    Shellock, F.G.2
  • 4
    • 0022256915 scopus 로고
    • The effect on medical metal implants by magnetic fields of magnetic resonance imaging
    • Mesgarzadeh, M., Revesz, G., Bonakdarpour, A. et al., The effect on medical metal implants by magnetic fields of magnetic resonance imaging, Skeletal Radiol., 14 (1985) 205-206.
    • (1985) Skeletal Radiol. , vol.14 , pp. 205-206
    • Mesgarzadeh, M.1    Revesz, G.2    Bonakdarpour, A.3
  • 5
    • 0025718057 scopus 로고
    • Politics, guidelines, and recommendations for MR imaging, safety and patient management
    • Shellock, F.G., Kanal, E. and SMRI safety committee, Politics, guidelines, and recommendations for MR imaging, safety and patient management, J. Magn. Reson. Imaging, 1 (1991) 97-101.
    • (1991) J. Magn. Reson. Imaging , vol.1 , pp. 97-101
    • Shellock, F.G.1    Kanal, E.2
  • 6
    • 0027379107 scopus 로고
    • MR procedures and biomedical implants, materials and devices: 1993 update
    • Shellock, F.G., Morisoli, S. and Kanal, E., MR procedures and biomedical implants, materials and devices: 1993 update, Radiology, 189 (1993) 587-599.
    • (1993) Radiology , vol.189 , pp. 587-599
    • Shellock, F.G.1    Morisoli, S.2    Kanal, E.3
  • 7
    • 0021321818 scopus 로고
    • Artifacts and hazards in NMR imaging due to metal implants and cardiac pacemakers
    • Zimmermann, B. and Faul, D., Artifacts and hazards in NMR imaging due to metal implants and cardiac pacemakers, Diagn. Imag. Clin. Med., 53 (1984) 53-56.
    • (1984) Diagn. Imag. Clin. Med. , vol.53 , pp. 53-56
    • Zimmermann, B.1    Faul, D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.