메뉴 건너뛰기




Volumn 42, Issue 4, 1997, Pages 625-636

Monte Carlo design study of a moderated 252Cf source for in vivo neutron activation analysis of aluminium

Author keywords

[No Author keywords available]

Indexed keywords

ALUMINUM; CALIFORNIUM 252;

EID: 0030961964     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/42/4/002     Document Type: Article
Times cited : (8)

References (22)
  • 1
    • 0024337360 scopus 로고
    • Disturbance of cerebral function by aluminium in haemodialysis patients without overt aluminium toxicity
    • Altmann P, Dhanesha U, Hamon J, Blair J, Cunningham J and Marsh F 1989 Disturbance of cerebral function by aluminium in haemodialysis patients without overt aluminium toxicity The Lancet 334 7-12
    • (1989) The Lancet , vol.334 , pp. 7-12
    • Altmann, P.1    Dhanesha, U.2    Hamon, J.3    Blair, J.4    Cunningham, J.5    Marsh, F.6
  • 2
    • 0003480591 scopus 로고
    • MCNP - A general Monte Carlo code for neutron and photon transport
    • Briesmeister J F 1993 MCNP - a general Monte Carlo code for neutron and photon transport Los Alamos National Laboratory Report LA 7396-M
    • (1993) Los Alamos National Laboratory Report , vol.LA 7396-M
    • Briesmeister, J.F.1
  • 3
    • 0021637916 scopus 로고
    • Techniques of in vivo neutron activation analysis
    • Chettle D R and Fremlin J H 1984 Techniques of in vivo neutron activation analysis Phys. Med. Biol. 29 1111-43
    • (1984) Phys. Med. Biol. , vol.29 , pp. 1111-1143
    • Chettle, D.R.1    Fremlin, J.H.2
  • 5
    • 0026678475 scopus 로고
    • A feasibility study of the in vivo measurement of aluminium in peripheral bone
    • Green S and Chettle D R 1992 A feasibility study of the in vivo measurement of aluminium in peripheral bone Phys. Med. Biol. 37 2287-96
    • (1992) Phys. Med. Biol. , vol.37 , pp. 2287-2296
    • Green, S.1    Chettle, D.R.2
  • 8
    • 0014975383 scopus 로고
    • Calculation of the dose distribution about californium-252 needles in tissue
    • Krishnaswamy V 1971 Calculation of the dose distribution about californium-252 needles in tissue Radiology 98 155-60
    • (1971) Radiology , vol.98 , pp. 155-160
    • Krishnaswamy, V.1
  • 9
    • 0025005903 scopus 로고
    • Renal bone disease 1990: An unmet challenge for the nephrologist
    • Malluche H and Faugere MC 1990 Renal bone disease 1990: an unmet challenge for the nephrologist Kidney Int. 38 193-211
    • (1990) Kidney Int. , vol.38 , pp. 193-211
    • Malluche, H.1    Faugere, M.C.2
  • 10
    • 0006391256 scopus 로고
    • X-ray fluorescence technique for in vivo analysis of natural and administered trace elements
    • ed K J Ellis, S Yasamura and W D Morgan (London: IPSM)
    • Mattsson S, Christofferson J O, Jonson R, and Nilsson U 1987 X-ray fluorescence technique for in vivo analysis of natural and administered trace elements In Vivo Body Composition Studies ed K J Ellis, S Yasamura and W D Morgan (London: IPSM) pp 318-24
    • (1987) In Vivo Body Composition Studies , pp. 318-324
    • Mattsson, S.1    Christofferson, J.O.2    Jonson, R.3    Nilsson, U.4
  • 13
    • 1842378264 scopus 로고    scopus 로고
    • PhD Thesis (University of Wales)
    • Natto S S A 1996 PhD Thesis (University of Wales)
    • (1996)
    • Natto, S.S.A.1
  • 16
    • 0020066934 scopus 로고
    • Reversal of aluminium induced hemodialysis anemia by a low aluminium dialysate
    • O'Hare J A and Murnughan D J 1982 Reversal of aluminium induced hemodialysis anemia by a low aluminium dialysate New Engl. J. Med. 306 654-8
    • (1982) New Engl. J. Med. , vol.306 , pp. 654-658
    • O'Hare, J.A.1    Murnughan, D.J.2
  • 21
    • 0027313078 scopus 로고
    • Design of a californium-based epithermal neutron beam for neutron capture therapy
    • Yanch J C, Kim J K and Wilson M K 1993 Design of a californium-based epithermal neutron beam for neutron capture therapy Phys. Med. Biol. 38 1145-55
    • (1993) Phys. Med. Biol. , vol.38 , pp. 1145-1155
    • Yanch, J.C.1    Kim, J.K.2    Wilson, M.K.3
  • 22
    • 0026617017 scopus 로고
    • 252Cf sources for neutron radiotherapy with and without augmentation by boron neutron capture therapy
    • 252Cf sources for neutron radiotherapy with and without augmentation by boron neutron capture therapy Radiat. Res. 131 249-56
    • (1992) Radiat. Res. , vol.131 , pp. 249-256
    • Yanch, J.C.1    Zamenhof, R.G.2