Volumn 204, Issue 1, 1997, Pages 268-272

Internally stabilized spine: Optimal choice of frequency-encoding gradient direction during MR imaging minimizes susceptibility artifact from titanium vertebral body screws

Author keywords

Magnetic resonance (MR), artifact; Magnetic resonance (MR), comparative studies; Magnetic resonance (MR), technology; Spine, MR; Spine, surgery

Indexed keywords

ADULT; AGED; ARTICLE; ARTIFACT; BONE SCREW; CLINICAL ARTICLE; FEMALE; HUMAN; IMAGE ANALYSIS; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; OSTEOSYNTHESIS; PHANTOM; PRIORITY JOURNAL; SPINE DISEASE; SPINE STABILIZATION; TREATMENT INDICATION; TREATMENT OUTCOME; VERTEBRA BODY;

EID: 0030959636     PISSN: 00338419     EISSN: None     Source Type: Journal    
DOI: 10.1148/radiology.204.1.9205258     Document Type: Article
Times cited : (40)

References (10)
  • 1
    • 0026701044 scopus 로고
    • Susceptibility artifact in spin-echo MR imaging of the pituitary gland
    • Sakurai K, Fujita N, Harada K, Kim SW, Nakanishi K, Kazuka T. Susceptibility artifact in spin-echo MR imaging of the pituitary gland. AJNR 1992; 13:1301-1308.
    • (1992) AJNR , vol.13 , pp. 1301-1308
    • Sakurai, K.1    Fujita, N.2    Harada, K.3    Kim, S.W.4    Nakanishi, K.5    Kazuka, T.6
  • 2
    • 0029003093 scopus 로고
    • Magnetic susceptibility artifacts on high-resolution MR of the temporal bone
    • Oehler MC, Schmalbrock P, Chakeres D, Kurucay S. Magnetic susceptibility artifacts on high-resolution MR of the temporal bone. AJNR 1995; 16:1135-1143.
    • (1995) AJNR , vol.16 , pp. 1135-1143
    • Oehler, M.C.1    Schmalbrock, P.2    Chakeres, D.3    Kurucay, S.4
  • 5
    • 0029896023 scopus 로고    scopus 로고
    • Needle localization in MR-guided biopsy and aspiration: Effects of field strength, sequence design, and magnetic field orientation
    • Lewin JS, Duerk JL, Jain VR, Petersilge CA, Chao CP, Haaga JR. Needle localization in MR-guided biopsy and aspiration: effects of field strength, sequence design, and magnetic field orientation. AJR 1996; 166:1337-1345.
    • (1996) AJR , vol.166 , pp. 1337-1345
    • Lewin, J.S.1    Duerk, J.L.2    Jain, V.R.3    Petersilge, C.A.4    Chao, C.P.5    Haaga, J.R.6
  • 6
    • 0023006852 scopus 로고
    • MR-guided aspiration biopsy: Needle design and clinical trials
    • Mueller PR, Stark DD, Simone JF, et al. MR-guided aspiration biopsy: needle design and clinical trials. Radiology 1986; 161:605-609.
    • (1986) Radiology , vol.161 , pp. 605-609
    • Mueller, P.R.1    Stark, D.D.2    Simone, J.F.3
  • 7
    • 0023796922 scopus 로고
    • Magnetic susceptibility artifacts in gradient-recalled echo MR imaging
    • Czervionke LF, Daniels DL, Wehrli FW, et al. Magnetic susceptibility artifacts in gradient-recalled echo MR imaging. AJNR 1988; 9:1149-1155.
    • (1988) AJNR , vol.9 , pp. 1149-1155
    • Czervionke, L.F.1    Daniels, D.L.2    Wehrli, F.W.3
  • 9
    • 0028097780 scopus 로고
    • Metallic artifacts on MR images of the postoperative spine: Reduction with fast spin-echo techniques
    • Tartaglino LM, Flanders AE, Vinitski S, Friedman DP. Metallic artifacts on MR images of the postoperative spine: reduction with fast spin-echo techniques. Radiology 1994; 190:565-569.
    • (1994) Radiology , vol.190 , pp. 565-569
    • Tartaglino, L.M.1    Flanders, A.E.2    Vinitski, S.3    Friedman, D.P.4
  • 10
    • 0027601461 scopus 로고
    • Conventional and fast spin-echo MR imaging: Minimizing echo time
    • Vinitski S, Mitchell DG, Einstein SG, et al. Conventional and fast spin-echo MR imaging: minimizing echo time. JMRI 1993; 3:501-507.
    • (1993) JMRI , vol.3 , pp. 501-507
    • Vinitski, S.1    Mitchell, D.G.2    Einstein, S.G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.