메뉴 건너뛰기




Volumn 23, Issue 2, 1997, Pages 231-244

An improved flow evaluation scheme in orifices of different aspect ratios

Author keywords

Color Doppler flow mapping; Hemodynamics; Numerical simulation; Ultrasound echocardiography; Valvular regurgitation proximal orifice flow field

Indexed keywords

COMPUTATIONAL METHODS; COMPUTER SIMULATION; ECHOCARDIOGRAPHY; FINITE ELEMENT METHOD; FLOW PATTERNS; ORIFICES; THREE DIMENSIONAL; ULTRASONIC IMAGING;

EID: 0030953616     PISSN: 03015629     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0301-5629(96)00228-1     Document Type: Article
Times cited : (7)

References (21)
  • 1
    • 0029038971 scopus 로고
    • A Numerical and Experimental Investigation of the Flow Acceleration Region Proximal to an Orifice
    • Anayiotos A, Perry GJ, Myers JG, Green DW, Fan PH. A Numerical and Experimental Investigation of the Flow Acceleration Region Proximal to an Orifice. Ultrasound Med Biol 1995;21:501-516.
    • (1995) Ultrasound Med Biol , vol.21 , pp. 501-516
    • Anayiotos, A.1    Perry, G.J.2    Myers, J.G.3    Green, D.W.4    Fan, P.H.5
  • 2
    • 0027633416 scopus 로고
    • The shape of the proximal isovelocity surface area varies with regurgitant orifice size and distance from the orifice. Computer simulation and model experiments with color M-mode technique,"
    • Barclay SA, Eidenvall L, Karlsson M, Andersson G, Xiong C. The shape of the proximal isovelocity surface area varies with regurgitant orifice size and distance from the orifice. Computer simulation and model experiments with color M-mode technique," J Am Soc Echocardiogr 1993;6:433-445.
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 433-445
    • Barclay, S.A.1    Eidenvall, L.2    Karlsson, M.3    Andersson, G.4    Xiong, C.5
  • 4
    • 0027516069 scopus 로고
    • Noninvasive estimation of regurgitant flow rate and volume in patients with mitral regurgitation by color mapping of accelerating flow field
    • Chen C, Koschyk D, Brockhoff C, Heik S, Hamm C. Noninvasive estimation of regurgitant flow rate and volume in patients with mitral regurgitation by color mapping of accelerating flow field. J Am Coll Cardiol 1993;21:374-83.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 374-383
    • Chen, C.1    Koschyk, D.2    Brockhoff, C.3    Heik, S.4    Hamm, C.5
  • 5
    • 0029424049 scopus 로고
    • Performance of phase contrast angiography in quantifying valvular regurgitation: An in-vitro model
    • Fox JF, Anayiotos AS, Doyle M, Perry GJ. Performance of phase contrast angiography in quantifying valvular regurgitation: An in-vitro model. Advances in Bioengineering 1995;31:361-3622.
    • (1995) Advances in Bioengineering , vol.31 , pp. 361-3622
    • Fox, J.F.1    Anayiotos, A.S.2    Doyle, M.3    Perry, G.J.4
  • 6
    • 0026548875 scopus 로고
    • Color Doppler determination of regurgitant flow: From proximal isovelocity surface areas to proximal velocity profiles
    • Giesler MO, Stauch M. Color Doppler determination of regurgitant flow: From proximal isovelocity surface areas to proximal velocity profiles. Echocardiography 1992;9:51-62.
    • (1992) Echocardiography , vol.9 , pp. 51-62
    • Giesler, M.O.1    Stauch, M.2
  • 8
    • 0028793116 scopus 로고
    • Incremental value of three-dimensional echocardiography over transesophageal multiplane two-dimensional echocardiography in qualitative and quantitative assessment of cardiac masses and defects
    • Nanda NC, Abd-El-Rahman SM, Khatri G, Agrawal G, El-Sayed AA. Incremental value of three-dimensional echocardiography over transesophageal multiplane two-dimensional echocardiography in qualitative and quantitative assessment of cardiac masses and defects. Echocardiography 1995;12:619-628.
    • (1995) Echocardiography , vol.12 , pp. 619-628
    • Nanda, N.C.1    Abd-El-Rahman, S.M.2    Khatri, G.3    Agrawal, G.4    El-Sayed, A.A.5
  • 9
    • 0029901691 scopus 로고    scopus 로고
    • Accuracy of color Doppler velocity in the flow field proximal to a regurgitant orifice - Implications for color Doppler quantification of valvular regurgitation
    • Perry GJ, Anayiotos AS, Green DW, Myers JG, Fan PH. Accuracy of color Doppler velocity in the flow field proximal to a regurgitant orifice - implications for color Doppler quantification of valvular regurgitation. Ultrasound Med Biol 1996;22:605-621.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 605-621
    • Perry, G.J.1    Anayiotos, A.S.2    Green, D.W.3    Myers, J.G.4    Fan, P.H.5
  • 12
    • 0026537396 scopus 로고
    • Impact of finite orifice size on proximal flow convergence: Implications for Doppler quantification of valvular regurgitation
    • Rodriguez L, Anconina J, Flanchskampf FA, Weyman AE, Levine RA, Thomas JD. Impact of finite orifice size on proximal flow convergence: Implications for Doppler quantification of valvular regurgitation. Circ Res 1992;70:923-930.
    • (1992) Circ Res , vol.70 , pp. 923-930
    • Rodriguez, L.1    Anconina, J.2    Flanchskampf, F.A.3    Weyman, A.E.4    Levine, R.A.5    Thomas, J.D.6
  • 13
    • 0028951039 scopus 로고
    • Nature of flow acceleration into a finite-sized orifice: Steady and pulsatile flow studies on the flow convergence region using simultaneous ultrasound Doppler flow mapping and laser Doppler velocimetry
    • Shandas R, Gharib M, Sahn DJ. Nature of flow acceleration into a finite-sized orifice: Steady and pulsatile flow studies on the flow convergence region using simultaneous ultrasound Doppler flow mapping and laser Doppler velocimetry. J Am Coll Cardiol 1995;25:1199-1212.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 1199-1212
    • Shandas, R.1    Gharib, M.2    Sahn, D.J.3
  • 14
    • 0028146359 scopus 로고
    • Estimation of regurgitant flow volume based on centerline velocity/distance profiles using digital M-Q Doppler; Application to orifices of different shapes
    • Shiota T, Teien D, Deng YB, Shandas R, Sahn DJ. Estimation of regurgitant flow volume based on centerline velocity/distance profiles using digital M-Q Doppler; Application to orifices of different shapes. J Am Coll Cardiol 1994;24:440-445.
    • (1994) J Am Coll Cardiol , vol.24 , pp. 440-445
    • Shiota, T.1    Teien, D.2    Deng, Y.B.3    Shandas, R.4    Sahn, D.J.5
  • 15
    • 0028238291 scopus 로고
    • Evaluation of mitral regurgitation using a digitally determined Doppler flow convergence 'centerline' acceleration method. Studies in an animal model with quantified mitral regurgitation."
    • Shiota T, Jones M, Teien DE, Yamada I, Passafini A. Evaluation of mitral regurgitation using a digitally determined Doppler flow convergence 'centerline' acceleration method. Studies in an animal model with quantified mitral regurgitation." Circulation 1994;89:2879-2887.
    • (1994) Circulation , vol.89 , pp. 2879-2887
    • Shiota, T.1    Jones, M.2    Teien, D.E.3    Yamada, I.4    Passafini, A.5
  • 16
    • 0027157399 scopus 로고
    • Calculation of volume flow rate by the proximal isovelocity surface area method: Simplified approach using CFM zero baseline shift
    • Utsunomiya T, Doshi R, Patel D, Mehta K, Nguyen D. Calculation of volume flow rate by the proximal isovelocity surface area method: Simplified approach using CFM zero baseline shift. J Am Coll Cardiol 1993;22:277-282.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 277-282
    • Utsunomiya, T.1    Doshi, R.2    Patel, D.3    Mehta, K.4    Nguyen, D.5
  • 17
    • 0025728517 scopus 로고
    • Doppler color flow proximal isovelocity surface area method for estimating volume flow rate: Effects of orifice shape and machine factors
    • Utsunomiya T, Ogawa T, Doshi R, Patel D, Quan M. Doppler color flow proximal isovelocity surface area method for estimating volume flow rate: Effects of orifice shape and machine factors. J Am Coll Cardiol 1991;17:1103-1111.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1103-1111
    • Utsunomiya, T.1    Ogawa, T.2    Doshi, R.3    Patel, D.4    Quan, M.5
  • 18
    • 0027004009 scopus 로고
    • Impact of wall filtration on the accuracy of quantitative CFM velocity measurements: Numerical and in vitro study
    • Vandervoort PM, Aghassi DS, Thomas JD. Impact of wall filtration on the accuracy of quantitative CFM velocity measurements: Numerical and in vitro study. Advances in Bioengineering 1992;22:367-70.
    • (1992) Advances in Bioengineering , vol.22 , pp. 367-370
    • Vandervoort, P.M.1    Aghassi, D.S.2    Thomas, J.D.3
  • 21
    • 0003906102 scopus 로고    scopus 로고
    • The mathematical analysis of the arterial circulation in a state of oscillitory motion
    • Wright Air Development Center 1957.
    • Womerseley JR. The mathematical analysis of the arterial circulation in a state of oscillitory motion. Wright Air Development Center 1957. Technical Report WADC-TR56-614, 5-18.
    • Technical Report WADC-TR56-614 , pp. 5-18
    • Womerseley, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.