메뉴 건너뛰기




Volumn 37, Issue 3, 1997, Pages 309-312

Evaluation of donor skin disinfection methods

Author keywords

[No Author keywords available]

Indexed keywords

2 PROPANOL; CHLORHEXIDINE GLUCONATE; IODINE; POVIDONE IODINE; SOAP;

EID: 0030950545     PISSN: 00411132     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1537-2995.1997.37397240214.x     Document Type: Article
Times cited : (90)

References (15)
  • 1
    • 0025718010 scopus 로고
    • Blood product-associated bacterial sepsis
    • Goldman M, Blajchman MA. Blood product-associated bacterial sepsis. Transfus Med Rev 1991;5:73-83.
    • (1991) Transfus Med Rev , vol.5 , pp. 73-83
    • Goldman, M.1    Blajchman, M.A.2
  • 3
    • 0025835345 scopus 로고
    • Septic reactions to platelet transfusions. A persistent problem
    • Morrow JF, Braine HG, Kickler TS, et al. Septic reactions to platelet transfusions. A persistent problem. JAMA 1991;266:555-8.
    • (1991) JAMA , vol.266 , pp. 555-558
    • Morrow, J.F.1    Braine, H.G.2    Kickler, T.S.3
  • 4
    • 0027278187 scopus 로고
    • The effect of skin disinfection materials on reducing blood culture contamination
    • Schifman RB, Pindur A. The effect of skin disinfection materials on reducing blood culture contamination. Am J Clin Pathol 1993;99:536-8.
    • (1993) Am J Clin Pathol , vol.99 , pp. 536-538
    • Schifman, R.B.1    Pindur, A.2
  • 5
    • 0027409080 scopus 로고
    • Effect of iodophor vs iodine tincture skin preparation on blood culture contamination rate
    • Strand CL, Wajsbort RR, Sturmann K. Effect of iodophor vs iodine tincture skin preparation on blood culture contamination rate. JAMA 1993;269:1004-6.
    • (1993) JAMA , vol.269 , pp. 1004-1006
    • Strand, C.L.1    Wajsbort, R.R.2    Sturmann, K.3
  • 6
    • 0025825996 scopus 로고
    • Prospective randomised trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial catheters
    • Maki DG, Ringer M, Alvarado CJ. Prospective randomised trial of povidone-iodine, alcohol, and chlorhexidine for prevention of infection associated with central venous and arterial catheters. Lancet 1991;338:339-43.
    • (1991) Lancet , vol.338 , pp. 339-343
    • Maki, D.G.1    Ringer, M.2    Alvarado, C.J.3
  • 7
    • 26344465824 scopus 로고
    • Evaluation of three skin preps for use prior to phlebotomy
    • Pleasant H, Marini J, Stehling L. Evaluation of three skin preps for use prior to phlebotomy (abstract). Transfusion 1994;34:(Suppl):14S.
    • (1994) Transfusion , vol.34 , Issue.SUPPL.
    • Pleasant, H.1    Marini, J.2    Stehling, L.3
  • 9
    • 0003483670 scopus 로고
    • Methods of testing antiseptics: Antimicrobials used topically in humans and procedures for hand scrubs
    • Block SS, ed. Philadelphia: Lea and Febiger
    • Bruch MK. Methods of testing antiseptics: antimicrobials used topically in humans and procedures for hand scrubs. In: Block SS, ed. Disinfection, sterilization, and preservation. 4th ed. Philadelphia: Lea and Febiger, 1991:1028-46.
    • (1991) Disinfection, Sterilization, and Preservation. 4th Ed. , pp. 1028-1046
    • Bruch, M.K.1
  • 10
    • 0019797595 scopus 로고
    • Development and validation of a neutralizer system for in vitro evaluation of some antiseptics
    • Sheikh W. Development and validation of a neutralizer system for in vitro evaluation of some antiseptics. Antimicrob Agents Chemother 1981;19:429-34.
    • (1981) Antimicrob Agents Chemother , vol.19 , pp. 429-434
    • Sheikh, W.1
  • 11
    • 0000769479 scopus 로고
    • A prospective study to determine the frequency of bacterial contamination in random donor platelet concentrates
    • Blajchman MA, Ali A, Lyn P, et al. A prospective study to determine the frequency of bacterial contamination in random donor platelet concentrates (abstract). Am Society Hematol 1994;84(Suppl 1):529a.
    • (1994) Am Society Hematol , vol.84 , Issue.1 SUPPL.
    • Blajchman, M.A.1    Ali, A.2    Lyn, P.3
  • 12
    • 1842363584 scopus 로고
    • Donor arm swabbing - How clean is clean?
    • Kitchen AD, Howe PH. Donor arm swabbing - how clean is clean? (abstract). Transfus Med 1995;5(Suppl):50.
    • (1995) Transfus Med , vol.5 , Issue.SUPPL. , pp. 50
    • Kitchen, A.D.1    Howe, P.H.2
  • 13
    • 0022513998 scopus 로고
    • Transfusion-related sepsis after prolonged platelet storage
    • Anderson KC, Lew MA, Gorgone BC, et al. Transfusion-related sepsis after prolonged platelet storage. Am J Med 1986;81:405-11.
    • (1986) Am J Med , vol.81 , pp. 405-411
    • Anderson, K.C.1    Lew, M.A.2    Gorgone, B.C.3
  • 14
    • 0004254371 scopus 로고
    • Bethesda: American Association of Blood Banks
    • Walker RH, ed. Technical manual. 11th ed. Bethesda: American Association of Blood Banks, 1993.
    • (1993) Technical Manual. 11th Ed.
    • Walker, R.H.1
  • 15
    • 0346755193 scopus 로고
    • Blood collection
    • Green TS, Steckler D, eds. Arlington: American Association of Blood Banks
    • Smith LG. Blood collection. In: Green TS, Steckler D, eds. Donor room policies and procedures. Arlington: American Association of Blood Banks, 1985:25-45.
    • (1985) Donor Room Policies and Procedures , pp. 25-45
    • Smith, L.G.1