메뉴 건너뛰기




Volumn 35, Issue 1, 1997, Pages 87-108

Ventilators in the operating room

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIST; ARTIFICIAL VENTILATION; BAROTRAUMA; HUMAN; INFECTION; INFECTIOUS COMPLICATION; MEDICAL INSTRUMENTATION; NUCLEAR MAGNETIC RESONANCE IMAGING; OPERATING ROOM; OXYGEN TOXICITY; PATIENT MONITORING; POSITIVE END EXPIRATORY PRESSURE; PRIORITY JOURNAL; REVIEW; TIDAL VOLUME; VENTILATOR;

EID: 0030947873     PISSN: 00205907     EISSN: None     Source Type: Journal    
DOI: 10.1097/00004311-199703510-00008     Document Type: Review
Times cited : (2)

References (25)
  • 3
    • 0023857963 scopus 로고
    • Enclosed afferent reservoir breathing systems
    • Miller DM, Miller JC. Enclosed afferent reservoir breathing systems. Br J Anaesth 1988;60:469
    • (1988) Br J Anaesth , vol.60 , pp. 469
    • Miller, D.M.1    Miller, J.C.2
  • 5
  • 6
    • 0023690951 scopus 로고
    • Hypoventilation caused by ventilator valve rupture
    • Sommer RM, Bhalla GS, Jackson JM, et al. Hypoventilation caused by ventilator valve rupture. Anesth Analg 1988;67:999
    • (1988) Anesth Analg , vol.67 , pp. 999
    • Sommer, R.M.1    Bhalla, G.S.2    Jackson, J.M.3
  • 8
    • 0024798279 scopus 로고
    • Potential for barotrauma or hypoventilation with the North American Dräger AV-E ventilator
    • Eisenkraft JB. Potential for barotrauma or hypoventilation with the North American Dräger AV-E ventilator. J Clin Anesth 1989;1:452
    • (1989) J Clin Anesth , vol.1 , pp. 452
    • Eisenkraft, J.B.1
  • 9
    • 0022973214 scopus 로고
    • Excessive airway pressure due to a malfunctioning anesthesia ventilator
    • Roth S, Tweedie E, Sommer RM. Excessive airway pressure due to a malfunctioning anesthesia ventilator. Anesthesiology 1986;65:532
    • (1986) Anesthesiology , vol.65 , pp. 532
    • Roth, S.1    Tweedie, E.2    Sommer, R.M.3
  • 10
    • 0023176580 scopus 로고
    • Tidal volume changes due to the interaction of anesthesia machine and anesthesia ventilator
    • Gravenstein N, Banner MJ, McLaughlin G. Tidal volume changes due to the interaction of anesthesia machine and anesthesia ventilator. J Clin Monit 1987;3:187
    • (1987) J Clin Monit , vol.3 , pp. 187
    • Gravenstein, N.1    Banner, M.J.2    McLaughlin, G.3
  • 13
    • 0024564607 scopus 로고
    • Positive end-expiratory pressure: Implications for tidal volume changes in anesthesia machine ventilation
    • Elliott WR, Harris AE, Philip JH. Positive end-expiratory pressure: implications for tidal volume changes in anesthesia machine ventilation. J Clin Monit 1989;5:100
    • (1989) J Clin Monit , vol.5 , pp. 100
    • Elliott, W.R.1    Harris, A.E.2    Philip, J.H.3
  • 14
    • 85036449203 scopus 로고
    • Anesthesia ventilator performance, delivered tidal volume, and PEEP
    • abstract
    • Pan PH, van der Aa JJ. Anesthesia ventilator performance, delivered tidal volume, and PEEP. Anesthesiology 1990;73(3A):A420 (abstract)
    • (1990) Anesthesiology , vol.73 , Issue.3 A
    • Pan, P.H.1    Van Der Aa, J.J.2
  • 15
  • 16
    • 0023991699 scopus 로고
    • Modification of an anesthesia machine for use during magnetic resonance imaging
    • Rao CC, McNiece WL, Emhardt J. Modification of an anesthesia machine for use during magnetic resonance imaging. Anesthesiology 1988;68:640
    • (1988) Anesthesiology , vol.68 , pp. 640
    • Rao, C.C.1    McNiece, W.L.2    Emhardt, J.3
  • 18
    • 0028688503 scopus 로고
    • La ventilation mecanique en IRM chez l'enfant. Contraintes anesthesiques
    • Sifeddine S, Badaoui R, Hassi N, et al. La ventilation mecanique en IRM chez l'enfant. Contraintes anesthesiques. Cahiers Anesthesiol 1994;42:583-587
    • (1994) Cahiers Anesthesiol , vol.42 , pp. 583-587
    • Sifeddine, S.1    Badaoui, R.2    Hassi, N.3
  • 19
    • 0022994993 scopus 로고
    • Anesthetic management of acutely ill patients during magnetic resonance imaging
    • Smith DS, Askey ZP, Young ML, et al. Anesthetic management of acutely ill patients during magnetic resonance imaging. Anesthesiology 1986;65:710
    • (1986) Anesthesiology , vol.65 , pp. 710
    • Smith, D.S.1    Askey, Z.P.2    Young, M.L.3
  • 20
    • 0021341374 scopus 로고
    • An analysis of major errors and equipment failures in anesthesia management: Considerations for prevention and detection
    • Cooper JB, Newbower RS, Kitz RJ. An analysis of major errors and equipment failures in anesthesia management: considerations for prevention and detection. Anesthesiology 1984;60:34-42
    • (1984) Anesthesiology , vol.60 , pp. 34-42
    • Cooper, J.B.1    Newbower, R.S.2    Kitz, R.J.3
  • 21
    • 0025270124 scopus 로고
    • Adverse respiratory events in anesthesia: A closed claims analysis
    • Caplan RA, Posner KL, Ward RJ, Cheney FW. Adverse respiratory events in anesthesia: a closed claims analysis. Anesthesiology 1990;72:828-833
    • (1990) Anesthesiology , vol.72 , pp. 828-833
    • Caplan, R.A.1    Posner, K.L.2    Ward, R.J.3    Cheney, F.W.4
  • 24
    • 0003442139 scopus 로고
    • Excerpted from American Society of Anesthesiologists. A copy of the full text can be obtained from ASA Executive Office, 520 N. Northwest Highway, Park Ridge, IL 60068-2573
    • Excerpted from American Society of Anesthesiologists. Standards for basic anesthetic monitoring, 1995. A copy of the full text can be obtained from ASA Executive Office, 520 N. Northwest Highway, Park Ridge, IL 60068-2573
    • (1995) Standards for Basic Anesthetic Monitoring


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.