메뉴 건너뛰기




Volumn 262, Issue 1-2, 1997, Pages 121-130

An algorithmic approach using κ/λ ratios to improve the diagnosis accuracy of urine protein electrophoresis and to reduce the volume required for immunoelectrophoresis

Author keywords

Bence Jones proteins; Immunoelectrophoresis; Kappa chains; Lambda chains; Nephelometry; Urine

Indexed keywords

BENCE JONES PROTEIN; IMMUNOGLOBULIN KAPPA CHAIN; IMMUNOGLOBULIN LAMBDA CHAIN;

EID: 0030947177     PISSN: 00098981     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0009-8981(97)06549-2     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 0024854467 scopus 로고
    • Primary systemic amyloidosis - A diagnostic primer
    • Gertz MA, Kyle RA. Primary systemic amyloidosis - a diagnostic primer. Mayo Clin Proc 1989;64:1505-1519.
    • (1989) Mayo Clin Proc , vol.64 , pp. 1505-1519
    • Gertz, M.A.1    Kyle, R.A.2
  • 2
    • 0342737038 scopus 로고
    • Analysis of free light chains of the immunoglobulins in clinical laboratories: Critical review
    • Levinson SS, Keren DF. Analysis of free light chains of the immunoglobulins in clinical laboratories: Critical review. Clin Chem 1994;39:1734-1738.
    • (1994) Clin Chem , vol.39 , pp. 1734-1738
    • Levinson, S.S.1    Keren, D.F.2
  • 3
    • 0015276005 scopus 로고
    • Composition and variation of the gel electrophoretic fractions of plasma, cerebrospinal fluid and urine
    • Laurell CB. Composition and variation of the gel electrophoretic fractions of plasma, cerebrospinal fluid and urine. J Clin Lab Invest 1972;29, suppl 124:71-82.
    • (1972) J Clin Lab Invest , vol.29 , Issue.SUPPL. 124 , pp. 71-82
    • Laurell, C.B.1
  • 4
    • 0025815316 scopus 로고
    • κ/λ Ratio for confirming urinary free light chain in amyloidosis AL and other plasma cell dyscrasias
    • Levinson SS. κ/λ Ratio for confirming urinary free light chain in amyloidosis AL and other plasma cell dyscrasias. Clin Chem 1991;37:1122-1126.
    • (1991) Clin Chem , vol.37 , pp. 1122-1126
    • Levinson, S.S.1
  • 5
    • 0026582793 scopus 로고
    • Studies of Bence Jones proteins by immunonephelometry
    • Levinson SS. Studies of Bence Jones proteins by immunonephelometry. Ann Clin Lab Sci 1992;22:100-109.
    • (1992) Ann Clin Lab Sci , vol.22 , pp. 100-109
    • Levinson, S.S.1
  • 6
    • 0022870712 scopus 로고
    • Urinary protein as measured with pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer
    • Watanabe N, Kamel S, Ohkubo A, Yamanaka M, Ohsawa S, Makino K, Tokuda K. Urinary protein as measured with pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer. Clin Chem 1986;32:1551-1554.
    • (1986) Clin Chem , vol.32 , pp. 1551-1554
    • Watanabe, N.1    Kamel, S.2    Ohkubo, A.3    Yamanaka, M.4    Ohsawa, S.5    Makino, K.6    Tokuda, K.7
  • 8
    • 0020470654 scopus 로고
    • Radioimmunoassay of free light chains of immunoglobulins in urine
    • Robinson EL, Gowland E, Ward ID, Scarffe JH. Radioimmunoassay of free light chains of immunoglobulins in urine. Clin Chem 1982;28:2254-2258.
    • (1982) Clin Chem , vol.28 , pp. 2254-2258
    • Robinson, E.L.1    Gowland, E.2    Ward, I.D.3    Scarffe, J.H.4
  • 9
    • 0025278422 scopus 로고
    • The optimum urine collections and monitoring of Bence-Jones proteinuria
    • Bridgden ML, Neal ED, McNeely MDD, Hoag GN. The optimum urine collections and monitoring of Bence-Jones proteinuria. Am J Clin Pathol 1990;93:689-693.
    • (1990) Am J Clin Pathol , vol.93 , pp. 689-693
    • Bridgden, M.L.1    Neal, E.D.2    McNeely, M.D.D.3    Hoag, G.N.4
  • 10
    • 0026092909 scopus 로고
    • Urine collection for the detection of Bence Jones proteinuria
    • Pascalli E, Urine collection for the detection of Bence Jones proteinuria. Am J Clin Pathol 1991;95: 266-267.
    • (1991) Am J Clin Pathol , vol.95 , pp. 266-267
    • Pascalli, E.1
  • 11
    • 0027326076 scopus 로고
    • Interference by polyclonal free light chains with identification of Bence Jones proteins
    • Hess PP, Mastropoulo W, Thompson GD, Levinson SS. Interference by polyclonal free light chains with identification of Bence Jones proteins. Clin Chem 1993;39:1734-1738.
    • (1993) Clin Chem , vol.39 , pp. 1734-1738
    • Hess, P.P.1    Mastropoulo, W.2    Thompson, G.D.3    Levinson, S.S.4
  • 12
    • 0030052812 scopus 로고    scopus 로고
    • Hemoglobin interference with urinary Bence Jones protein analysis on electrophoresis
    • Hobbs GA, Levinson SS. Hemoglobin interference with urinary Bence Jones protein analysis on electrophoresis. Ann Clin Lab Sci 1996;26:71-75.
    • (1996) Ann Clin Lab Sci , vol.26 , pp. 71-75
    • Hobbs, G.A.1    Levinson, S.S.2
  • 13
    • 0023216680 scopus 로고
    • Use of kappa and lambda chain quantitation for detection of immunoglobulin abnormalities in serum
    • Normansell DE. Use of kappa and lambda chain quantitation for detection of immunoglobulin abnormalities in serum. Diagn Clin Immunol 1987;5:100-103.
    • (1987) Diagn Clin Immunol , vol.5 , pp. 100-103
    • Normansell, D.E.1
  • 14
    • 0024205954 scopus 로고
    • Strategy to diagnose monoclonal gammopathies in serum: High resolution electrophoresis, immuno fixation, and κ/λ quantitation
    • Keren DF, Warren JS, Lowe JB. Strategy to diagnose monoclonal gammopathies in serum: High resolution electrophoresis, immuno fixation, and κ/λ quantitation. Clin Chem 1988;34:2196-2201.
    • (1988) Clin Chem , vol.34 , pp. 2196-2201
    • Keren, D.F.1    Warren, J.S.2    Lowe, J.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.