메뉴 건너뛰기




Volumn 79, Issue 6, 1997, Pages 829-834

Transthoracic echocardiographic assessment of periprosthetic mitral regurgitation using intravenous injection of sonicated albumin

Author keywords

[No Author keywords available]

Indexed keywords

ALBUNEX; HUMAN SERUM ALBUMIN;

EID: 0030945232     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(96)00884-3     Document Type: Article
Times cited : (2)

References (19)
  • 1
    • 0026682773 scopus 로고
    • Variability in the quantitation of mitral regurgitation by Doppler color flow mapping: Comparison of transthoracic and transesophageal studies
    • Castello R, Lenzen P, Aguirre F, Labovitz A. Variability in the quantitation of mitral regurgitation by Doppler color flow mapping: comparison of transthoracic and transesophageal studies. J Am Coll Cardiol. 20:1992;433-438.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 433-438
    • Castello, R.1    Lenzen, P.2    Aguirre, F.3    Labovitz, A.4
  • 3
    • 0026098344 scopus 로고
    • Regurgitant jet size by transesophageal compared with transthoracic Doppler color flow imaging
    • Smith MD, Harrison MR, Pinton R, Kandil H, Kwan OL, DeMaria AN. Regurgitant jet size by transesophageal compared with transthoracic Doppler color flow imaging. Circulation. 83:1991;79-86.
    • (1991) Circulation , vol.83 , pp. 79-86
    • Smith, M.D.1    Harrison, M.R.2    Pinton, R.3    Kandil, H.4    Kwan, O.L.5    Demaria, A.N.6
  • 5
    • 0023223358 scopus 로고
    • In vitro color flow, pulsed and continuous wave Doppler ultrasound masking of flow by prosthetic valves
    • Sprecher DL, Adamick R, Adams D, Kisslo J. In vitro color flow, pulsed and continuous wave Doppler ultrasound masking of flow by prosthetic valves. J Am Coll Cardiol. 9:1987;1306-1310.
    • (1987) J Am Coll Cardiol , vol.9 , pp. 1306-1310
    • Sprecher, D.L.1    Adamick, R.2    Adams, D.3    Kisslo, J.4
  • 7
    • 0027429973 scopus 로고
    • Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: Results of the phase III Albunex multicenter trial
    • Crouse LJ, Cheirif J, Hanly DE, Kisslo JA, Labovitz AJ, Raichlen JS, Schutz RW, Shah PM, Smith MD. Opacification and border delineation improvement in patients with suboptimal endocardial border definition in routine echocardiography: results of the phase III Albunex multicenter trial. J Am Coll Cardiol. 22:1993;1494-1500.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 1494-1500
    • Crouse, L.J.1    Cheirif, J.2    Hanly, D.E.3    Kisslo, J.A.4    Labovitz, A.J.5    Raichlen, J.S.6    Schutz, R.W.7    Shah, P.M.8    Smith, M.D.9
  • 8
    • 0027406872 scopus 로고
    • Enhancement of Doppler flow signals in the left heart chambers by intravenous injection of sonicated albumin
    • Terasawa A, Miyatake K, Nakatani S, Yamagishi M, Matsuda H, Beppu S. Enhancement of Doppler flow signals in the left heart chambers by intravenous injection of sonicated albumin. J Am Coll Cardiol. 21:1993;737-742.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 737-742
    • Terasawa, A.1    Miyatake, K.2    Nakatani, S.3    Yamagishi, M.4    Matsuda, H.5    Beppu, S.6
  • 9
    • 0028864285 scopus 로고
    • Improvement of transthoracic pulmonary venous flow Doppler signal with intravenous injection of sonicated albumin
    • Williams MJA, McClements BM, Picard MH. Improvement of transthoracic pulmonary venous flow Doppler signal with intravenous injection of sonicated albumin. J Am Coll Cardiol. 26:1995;1741-1746.
    • (1995) J Am Coll Cardiol , vol.26 , pp. 1741-1746
    • Williams, M.J.A.1    McClements, B.M.2    Picard, M.H.3
  • 10
    • 0026490314 scopus 로고
    • Clinical application of transpulmonary contrast-enhanced Doppler technique in the assessment of severity of aortic stenosis
    • Nakatani S, Imanishi T, Terasawa A, Beppu S, Nagata S, Miyatake K. Clinical application of transpulmonary contrast-enhanced Doppler technique in the assessment of severity of aortic stenosis. J Am Coll Cardiol. 20:1992;973-978.
    • (1992) J Am Coll Cardiol , vol.20 , pp. 973-978
    • Nakatani, S.1    Imanishi, T.2    Terasawa, A.3    Beppu, S.4    Nagata, S.5    Miyatake, K.6
  • 11
    • 0027410667 scopus 로고
    • Color flow imaging compared with quantitative Doppler assessment of severity of mitral regurgitation: Influence of eccentricity of jet and mechanism of regurgitation
    • Enriquez-Sarano M, Tajik AJ, Bailey KR, Seward JB. Color flow imaging compared with quantitative Doppler assessment of severity of mitral regurgitation: influence of eccentricity of jet and mechanism of regurgitation. J Am Coll Cardiol. 21:1993;1211-1219.
    • (1993) J Am Coll Cardiol , vol.21 , pp. 1211-1219
    • Enriquez-Sarano, M.1    Tajik, A.J.2    Bailey, K.R.3    Seward, J.B.4
  • 12
    • 0000141280 scopus 로고
    • Left ventricular inflow tract 1: The mitral valve
    • A.E. Weyman. Philadelphia: Lea & Febiger
    • Weyman AE. Left ventricular inflow tract 1: the mitral valve. Weyman AE. Principles and Practice of Echocardiography. 1994;391-470 Lea & Febiger, Philadelphia.
    • (1994) Principles and Practice of Echocardiography , pp. 391-470
    • Weyman, A.E.1
  • 13
    • 0025881952 scopus 로고
    • Adjacent solid boundaries alter the size of regurgitant jets on Doppler color flow maps
    • Cape EG, Yoganathan AP, Weyman AE, Levine RA. Adjacent solid boundaries alter the size of regurgitant jets on Doppler color flow maps. J Am Coll Cardiol. 17:1991;1094-1102.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1094-1102
    • Cape, E.G.1    Yoganathan, A.P.2    Weyman, A.E.3    Levine, R.A.4
  • 14
    • 0026561242 scopus 로고
    • Assessment of severity of mitral regurgitation by measuring regurgitant jet width at its origin with transesophageal Doppler color flow imaging
    • Tribouilloy C, Shen WF, Quéré J-P, Rey J-L, Choquet D, Dufossé H, Lesbre J-P. Assessment of severity of mitral regurgitation by measuring regurgitant jet width at its origin with transesophageal Doppler color flow imaging. Circulation. 85:1992;1248-1253.
    • (1992) Circulation , vol.85 , pp. 1248-1253
    • Tribouilloy, C.1    Shen, W.F.2    Quéré J-P3    Rey J-L4    Choquet, D.5    Dufossé, H.6    Lesbre J-P7
  • 15
    • 0343265560 scopus 로고
    • Evaluation of heart valve prostheses by transesophageal echocardiography
    • G. Maurer. New York: McGraw-Hill, Inc
    • Baumgartner H, Khan S, Maurer G. Evaluation of heart valve prostheses by transesophageal echocardiography. Maurer G. Transesophageal Echocardiography. 1994;87-108 McGraw-Hill, Inc, New York.
    • (1994) Transesophageal Echocardiography , pp. 87-108
    • Baumgartner, H.1    Khan, S.2    Maurer, G.3
  • 16
    • 0025765247 scopus 로고
    • Effect of mitral regurgitation on pulmonary venous velocities derived from transesophageal echocardiography color-guided pulsed Doppler imaging
    • Castello R, Pearson AC, Lenzen P, Labovitz AJ. Effect of mitral regurgitation on pulmonary venous velocities derived from transesophageal echocardiography color-guided pulsed Doppler imaging. J Am Coll Cardiol. 17:1991;1499-1506.
    • (1991) J Am Coll Cardiol , vol.17 , pp. 1499-1506
    • Castello, R.1    Pearson, A.C.2    Lenzen, P.3    Labovitz, A.J.4
  • 18
    • 0028830890 scopus 로고
    • Clinical evaluation of left heart Doppler contrast enhancement by a saccharide-based transpulmonary contrast agent
    • von Bibra H, Sutherland G, Becher H, Neudert J, Nihoyannopoulos P. Clinical evaluation of left heart Doppler contrast enhancement by a saccharide-based transpulmonary contrast agent. J Am Coll Cardiol. 25:1995;500-508.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 500-508
    • Von Bibra, H.1    Sutherland, G.2    Becher, H.3    Neudert, J.4    Nihoyannopoulos, P.5
  • 19
    • 0027312820 scopus 로고
    • Enhancement of mitral regurgitation and normal left atrial color Doppler flow signals with peripheral venous injection of a saccharide-based contrast agent
    • von Bibra H, Becher H, Firschke C, Schlief R, Emslander HP, Schömig A. Enhancement of mitral regurgitation and normal left atrial color Doppler flow signals with peripheral venous injection of a saccharide-based contrast agent. J Am Coll Cardiol. 22:1993;521-528.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 521-528
    • Von Bibra, H.1    Becher, H.2    Firschke, C.3    Schlief, R.4    Emslander, H.P.5    Schömig, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.